Phonak B90, B70, B50 User Manual

Phonak Bolero B-PR
U
)
(B90/B70/B50)
(B90/B70/B50
User Guide
ser Guide
This user guide is valid for:
Wireless hearing aids
Your hearing aid & charger details
Phonak Bolero B90-PR Phonak Bolero B70-PR Phonak Bolero B50-PR
Non wireless charging accessories
Phonak Charger Case BTE Phonak Power Pack Phonak Mini Charger BTE
2
2016 2016 2016
2016 2016 2016
If no box is checked and you do not know the
model of your hearing aid or charging accessories, please ask your hearing care professional.
Bolero B-PR contains a built-in and non-removable
rechargeable lithium-ion battery.
Please also read safety information regarding
handling rechargeable hearing aids (chapter 18).
Please ensure to charge and use the hearing aid
within operating temperature range: +5° to +40° Celsius (41° to 104° Fahrenheit)
Hearing aid models Earpieces
F Bolero B90-PR F Dome F Bolero B70-PR F SlimTip F Bolero B50-PRF Classic earmold
Charging accessories
F Charger Case BTE incl. power supply F Power Pack F Mini Charger BTE incl. power supply
Your hearing aids and chargers have been developed by Phonak – the world leader in hearing solutions based in Zurich, Switzerland.
These premium products are the result of decades of research and expertise and are designed to keep you connected to the beauty of sound! We thank you for making such a great choice and wish you many years of listening pleasure.
Please read the user guide carefully to make sure that you understand and get the best out of your hearing aids. For more information about features and benets, simply contact your hearing care professional.
Phonak - life is on www.phonak.com
3
4
Contents
Your hearing aid and charger
1. Quick guide
2. Parts of the hearing aid & charger Using the charger
3. Preparing the charger
4. Charging the hearing aids Using the hearing aid
5. Left & right hearing aid markings
6. Push button
7. On/O
8. Putting on the hearing aid
9. Removing the hearing aid Further information
10. Operating conditions
11. Care and maintenance
12. Exchanging the earpiece
13. Wireless accessories
14. Service and warranty
15. Compliance information
16. Information and description of symbols
17. Troubleshooting
18. Important safety information
12 14
21 22 23 24 26
28 29 31 34 35 37 42 46 50
1. Quick guide
Charging your hearing aids
6 8
After placing your hearing aid in the charger, the indicator light will slowly blink until the hearing aid is fully charged. When fully charged the indicator light will be constantly on, i.e. solid green light.
Left & right hearing aid markings
Blue marking for
left hearing aid.
Red marking for
right hearing aid.
Push button with indicator light
The push button has two functions: A short push can have various functions. The function for your hearing aid is indicated in your individual instructions.
A long push (3 seconds) is used to switch the hearing aid on/o.
On/O
Firmly press the button using the tip of your nger for 3 seconds until the indicator light blinks.
On: One short blink O: Two short blinks
Before using Bolero B-PR for the rst time, it is
recommended to charge it for 3 hours.
5
6
2. Parts of the hearing aid & charger
The following pictures show the hearing aid model and charger accessories described in this user guide. You can identify your personal models by:
• Checking “Your hearing aid & charger details” on page 3.
• Or comparing your hearing aid and charger with the following shown models.
Possible earpieces
Classic earmold
Bolero B-PR
Tube
Earpiece: Dome
(detachable)
SlimTip Dome
Push button with built-in green indicator light
Volume control
Charging contacts
Anchor
7
8
Charger Case BTE
Charger Case BTE with optional Power Pack
Cleaning tool
Space for drying capsule (cover closed)
Space for earpieces
Hearing aid charging inserts with left/right indicators
Space for drying capsule (cover open)
Drying capsule (optional)
Charger Case BTE
Indicator light for power
micro-USB connection to external power supply
Power Pack
micro-USB connection to external power supply
Battery check button
Indicator light for battery status and external power
Power Pack lock and release
9
10
Mini Charger BTE
Hearing aid charging inserts with left/right indicators
micro-USB connection to external power supply
Indicator light for power
3. Preparing the charger
3.1 Setting up the power supply
UK AUS US EU
Select the adapter that corresponds to your country.
a) Insert the top round end of the
adapter into the round corner of the power supply.
b) Click the bottom end of the adapter
in to lock into place.
c) To remove, pull back the tab on the
power supply.
d) Pull the adapter upwards to remove
it.
c
a
b
d
11
12
3.2 Connecting the power supply
a
d
c
b
a) Plug the larger end of the charging cable into the power
supply.
b) Plug the smaller end into the micro-USB port on the
charger. c) Plug the power supply into a power outlet. d) The indicator light is green when the charger is connected to the power supply.
4. Charging the hearing aids
Low power: You will hear two beeps when the battery is low. You will have approximately 60 minutes before you have to charge the hearing aids (this can vary, depending on the hearing aid settings).
4.1 Using the Charger Case BTE or Mini Charger BTE
Please refer to chapter 3 for how to set up the charger.
1
Insert the hearing aid into the charging inserts. Make sure the left and right hearing aid markings match the left (blue)/right (red) indicators next to the charging inserts. The hearing aids will automatically switch o when inserted into the charger.
13
14
2
The indicator light will slowly blink until the hearing aid is fully charged. When fully charged the indicator light will remain on, i.e. solid green light. The charging process will automatically stop when the batteries are fully charged, so the hearing aids can be safely left in the charger. It can take up to 3 hours to charge the hearing aids. The Charger Case BTE cover can be closed while charging.
Bolero B-PR charging times 100% charge: 3 h 80% charge: 90 min
50% charge: 60 min 30% charge: 30 min
15 16
3
Remove the hearing aids from the charging inserts and switch them on, refer to chapter 7.
Do not hold the tubes for removing the hearing aids
from the charger as this can damage the tube.
Bolero B-PR contains a built-in and non-
removable rechargeable lithium-ion battery.
Before using Bolero B-PR for the rst time, it is
recommended to charge it for 3 hours.
The hearing aid must be dry before charging,
see chapter 11.
Please ensure to charge and use the hearing aid
within operating temperature range: +5° to +40° Celsius (41° to 104° Fahrenheit).
17
4.2 Using the optional Power Pack
1
Attach the Power Pack to the Charger Case and lock it.
2
Plug in the micro-USB and connect to an external power supply. The Power Pack and hearing aids will be charged at the same time. While connected to an external power supply, the Power Pack indicator light will show the current battery charge status.
Before using Power Pack for the rst time, it is
recommended to charge it for 3 hours.
The Power Pack contains a built-in and non-
removable rechargeable lithium-polymer battery.
18
micro-USB connection to external power source
Indicator light battery status:
0%-29%
•• 30%-59%
••• 60%-100%
Battery check push button
Power Pack lock and release
3
The fully charged Power Pack oers 7 full charging cycles for a pair of hearing aids. To check the remaining battery capacity of the Power Pack, press the battery check push button (indicator lights will be o otherwise, to preserve battery).
Please ensure to charge the Power Pack within
operating temperature range: +5° to +40° Celsius (41° to 104° Fahrenheit)
19
20
5. Left & right hearing aid markings
6. Push button
There is a red or blue marking on the back of the hearing aid and on the SlimTube (if used). This will tell you if it is a left or a right hearing aid.
Blue marking for left hearing aid.
Red marking for right hearing aid.
21
The push button has two functions:
Short push
The push button on your hearing aid can have various functions or is not active. This depends on the programming of the hearing aid, which is indicated in your individual “Hearing aid instructions”. Please ask your hearing care professional for a printout.
Long push (3 seconds) The push button is used to switch the hearing aid on and o. Refer to next chapter.
22
7. On/O
To switch the hearing aid on or o, rmly press the button using the tip of your nger for 3 seconds until the indicator light blinks.
One short blink = hearing aid turns on
Two short blinks = hearing aid turns o
When you switch on the hearing aid you may hear a start-up melody.
8. Putting on the hearing aid
8.1 Putting on the hearing aid with classic earmold
1
Take the earmold up to your ear and place the ear canal part into your ear canal.
2
Place the hearing aid behind your ear.
3
Insert the upper part of the earmold into the upper part of the bowl of your ear.
23
24
8.2 Putting on the hearing aid with dome or SlimTip
9. Removing the hearing aid
9.1 Removing the hearing aid with classic earmold
1
Place the hearing aid behind your ear.
2
Insert the earpiece into your ear canal.
3
If there is an anchor attached to the earpiece, tuck it into the bowl of your ear to secure your hearing aid.
1
Lift the hearing aid above the upper part of your ear.
2
Grasp the earmold in your ear and gently remove it.
Please try to avoid gripping the tube to remove the
hearing aid.
25
26
9.2 Removing the hearing aid with dome or SlimTip
1
Pull on the bend of the tube and remove the hearing aid from behind the ear.
In very rare cases, the dome can remain in your ear
canal when removing the hearing tube from the ear. In the unlikely case that the dome does get stuck in your ear canal, it is strongly recommended to see a physician for safe removal.
10. Operating conditions
The product is designed such that it functions without problems or restrictions if used as intended, unless otherwise noted in these user guides.
Please ensure to charge the hearing aid and Power Pack within operating temperature range: +5° to +40° Celsius (41° to 104° Fahrenheit ) and atmospheric pressure range: 800 hPA to 1500 hPA.
Bolero B-PR are classied IP68 (depth of 1 meter for 60 minutes) and designed to be used in all daily life situations. Therefore you do not have to worry about getting the hearing aids exposed to a rain shower or sweat. However, Bolero B-PR is not intended to be used in water activities that includes chlorinated water, soap, salt water or other liquids with a chemical content.
Humidity during operation for the Charger Case, Mini Charger and Power Pack: 0% to 85% (non condensing).
27
28
11. Care and maintenance
Diligent and routine care of your hearing aid and chargers contribute to outstanding performance and a long service life.
Please use the following specications as a guideline. Further information regarding product safety, see chapter 18.2.
General information
Before using hair spray or applying cosmetics, you should remove your hearing aid from your ear, because these products may damage it.
Daily Hearing aid: Inspect the earpiece for earwax and
moisture deposits. Clean the surfaces with a lint-free cloth or use the small brush provided in the Charger Case. Never use cleaning agents such as household detergents, soap, etc. for cleaning your hearing aid. It is not recommended to rinse with water. If you need to clean your hearing aid intensively, ask your hearing care professional for advice and information on lters or drying capsules. Chargers: Make sure that charger inserts are clean. Never use cleaning agents such as household detergents, soap, etc. for cleaning your charger.
Your hearing aids are resistant to water, sweat and dust under the following conditions:
• After exposure to water, sweat or dust, the hearing aid
is cleaned and dried.
• The hearing aid is used and maintained as described in
this user guide.
Always make sure that the hearing aids and
charger are dry and clean before charging.
29
12. Exchanging the earpiece
If your hearing aid is tted with a SlimTube, you may need to exchange or clean the earpiece.
Please check the earpiece regularly and exchange or clean it if it looks dirty or if the hearing aid volume or sound quality is reduced. If a dome is used, it should be exchanged every 2-3 months.
Weekly Hearing aid: Clean the earpiece with a soft, damp cloth
or with a special cleaning cloth for hearing aids. For more in-depth maintenance instructions or for more than basic cleaning, please see your hearing care professional. Clean the charging contacts on the hearing aid with a soft, damp cloth. Chargers: Remove dust or dirt from the charger inserts.
30
2
Gently pull on the earpiece to remove.
12.1 Removing the earpiece from the SlimTube
1
Remove the earpiece from the SlimTube by holding the SlimTube in one hand and the earpiece in the other.
3
Clean the SlimTube with a lint-free cloth.
31
32
13. Wireless accessories
12.2 Attaching the earpiece to the SlimTube
1
Hold the SlimTube in one hand and the earpiece in the other.
2
Slide the earpiece over the sound outlet.
3
The SlimTube and the earpiece should t perfectly together.
A range of Phonak wireless accessories are available for you to use with your hearing aid.
Phonak RemoteMic***
Cell phone
Phonak EasyCall II with cell phone
Phonak PilotOne II remote control
Phonak DECT phone II
* The Phonak ComPilot II with neckloop or ComPilot Air II with clip to attach to clothing. They
also have basic remote control functionalities. For advanced control they can be used with the Phonak RemoteControl App.
** Audio sources (e.g. MP3 Player, computer, laptop, tablet) can be connected to the streaming
device via Bluetooth or audio cable.
*** Clipped onto the speaker’s clothing for better understanding over distance.
33
34
Phonak streaming device*
Phonak TVLink II connected to TV
MP3 Player/ Audio source**
14. Service and warranty
Local warranty
Please ask the hearing care professional where you purchased your hearing aids and chargers about the terms of the local warranty.
International warranty
Sonova AG oers a one year limited international warranty, valid from the date of purchase. This limited warranty covers manufacturing and material defects in the hearing aid and chargers respectively, but not accessories such as tubes, earpieces, external receivers. The warranty only comes into force if a proof of purchase is shown.
The international warranty does not aect any legal rights that you might have under applicable national legislation governing sale of consumer goods.
Warranty limitation
This warranty does not cover damage from improper handling or care, exposure to chemicals or undue stress. Damage caused by third parties or non-authorized service centers renders the warranty null and void. This warranty does not include any services performed by a hearing care professional in their oce.
Serial numbers Hearing aid left side: Hearing aid right side:
Charger Case: Power Pack: Mini Charger:
Date of purchase:
Authorized hearing care professional (stamp/signature):
35
36
15. Compliance information
Europe: Declaration of Conformity for the hearing aid
Hereby Sonova AG declares that this product meets the requirements of the Medical Devices Directive 93/42/EEC as well as the Radio and Telecommunications Terminal Equipment Directive 1999/5/EC. The full text of the Declaration of Conformity can be obtained from the manufacturer or the local Phonak representative whose address can be taken from the list on www.phonak.com (Phonak worldwide locations).
Australia/New Zealand:
Indicates a device’s compliance with applicable Radio Spectrum Management’s (RSM) and Australian Communications and Media Authority (ACMA) regulatory arrangements for the legal sale in New Zealand and Australia. The compliance label R-NZ is for radio products supplied in the New Zealand market under conformity level A1.
The wireless models listed on page 2 are certied under:
Phonak Bolero B-PR (B90/B70/B50)
USA FCC ID: KWC-BTER Canada IC: 2262A-BTER
37
38
Notice 1:
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions:
1) this device may not cause harmful interference, and
2) this device must accept any interference received, including interference that may cause undesired operation.
Notice 2:
Changes or modications made to this device not expressly approved by Sonova AG may void the FCC authorization to operate this device.
Notice 3:
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and ICES-003 of Industry Canada. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is
39
no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the device and receiver.
• Connect the device into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
40
Radio information of your wireless hearing aid
16. Information and description
of symbols
Antenna type
Operation frequency Occupied bandwidth (99% BW) Modulation Channel Operating range Use case
Magnetic eld strength @ 1 m
Integrated ferrite coil antenna (inductive)
10.6 MHz 496 kHz
DQPSK Single channel radio 18 cm (7”) Streaming of audio signal to receiving hearing aid on the other ear 3,6 dBμA/m
41
With the CE symbol, Sonova AG conrms that this product – including accessories – meets the requirements of the Medical Devices Directive 93/42/EEC as well as the R&TTE Directive 1999/5/EC on radio and telecommunications equipment. The numbers after the CE symbol correspond to the code of certied institutions that were consulted under the above­mentioned directives.
This symbol indicates that the products described in these user instructions adhere to the requirements for an applied part of Type B of EN 60601-1. The surface of the hearing aid is specied as an applied part of Type B.
Indicates the medical device manufacturer, as dened in EU Directive 93/42/EEC.
42
This symbol indicates that it is important for the user to read and take into account the relevant information in these user guides.
This symbol indicates that it is important for the user to pay attention to the relevant warning notices in these user guides.
Important information for handling and product safety.
This symbol confers that the electromagnetic interference from the device is under limits approved by the US Federal Communications Commission.
Indicates the manufacturer’s serial number so that a specic medical device can be identied.
Indicates the manufacturer’s catalogue number so that the medical device can be identied.
This symbol indicates that it is important for the user to read and take into account the relevant information in this user guide.
Temperature during transportation and storage: –20° to +60° Celsius (–4° to +140° Fahrenheit).
Humidity during storage: 0% to 70%, if not in use. See instruction in chapter 18.2 regarding drying the hearing aid after use.
Atmospheric pressure during transportation and storage: 200 hPA to 1500 hPa
During transportation keep dry.
43
44
The symbol with the crossed-out garbage bin is to make you aware that this hearing aid as well as chargers and Power Pack may not be thrown away as normal household waste. Please dispose of old or unused hearing aids and charger, at waste disposal sites intended for electronic waste, or give your hearing aid and charger to your hearing care professional for disposal. Proper disposal protects the environment and health.
17. Troubleshooting
17.1 Troubleshooting hearing aid
Problem
Hearing aid not functioning
Hearing aid whistles
Hearing aid not loud enough or distorted
Hearing aid plays two beeps Hearing aid will not start up Indicator light on hearing aid blinks fast while charging
Causes
Blocked SlimTube/earpiece Hearing aid switched o Electromagnetic disturbances occurred Battery fully discharged Hearing aid not inserted correctly into ear Cerumen in ear canal Volume too loud Low battery SlimTube/earpiece blocked Volume too low Hearing has changed Indication for low battery Battery fully discharged Faulty battery
What to do
Clean SlimTube opening/earpiece Press push button for 3 seconds (chapter 1+7) Press push button Insert hearing aid into the charger Charge hearing aid (chapter 4) Insert hearing aid correctly (chapter 8)
Contact your ENT/GP or hearing care professional Decrease volume if volume control available (chapter 6) Charge hearing aid (chapter 4) Clean SlimTube opening/earpiece Turn volume up if volume control available (chapter 6) Contact you hearing care professional Charge hearing aid (chapter 4) Charge hearing aid (chapter 4) Contact your hearing care professional if the battery life is not as expected
45
46
Problem
The indicator light on the hearing aid is o when placed in the charging inserts
Battery does not last the whole day
17.2 Troubleshooting charger
Problem
Charging does not start (no power pack used)
Charging does not start when using Power Pack
Causes
Hearing aid not inserted correctly into charger Charger not connected to power source Hearing aid is not fully charged Battery may need to be replaced
Causes
Charger Case or Mini Charger is not connected to power supply
Hearing aid not inserted correctly into charger Power Pack discharged
If the problem persists, contact you hearing care professional for
assistance.
47
48
What to do
Insert hearing aid correctly into charger (chapter 4)
Connect charger to external power supply
Charge hearing aid (chapter 4) Contact your hearing care professional; a battery replacement may be required
What to do
Connect charger to power supply or Power Pack (chapter 4.2)
Insert hearing aid correctly into charger (chapter 4.1)
Charge Power Pack (chapter 4.2)
18. Important safety information
Please read the information on the following pages before using your hearing aid and charging accessories.
A hearing aid will not restore normal hearing and will not prevent or improve a hearing impairment resulting from organic conditions. Infrequent use of a hearing aid does not permit a user to attain full benet from it. The use of a hearing aid is only part of hearing habilitation and may need to be supplemented by auditory training and instruction in lipreading.
The hearing aid is suitable for the home healthcare environment and due to their portability it may happen that it is used in professional healthcare facility environment like physician oces, dental oces etc.
18.1 Hazard warnings
The Phonak rechargeable hearing aids and the Phonak Power Pack contain lithium-ion batteries that can be taken onto airplanes as carry-on luggage. The Power Pack cannot be placed in the checked-in baggage and can only be placed in the carry-on luggage.
The intended use of hearing aids is to amplify and transmit sound to the ears and hereby compensate for impaired hearing. The hearing aids (specially programmed for each hearing loss) must only be used by the
intended person. They should not be used by any other person as they could damage hearing.
Changes or modications to the hearing aid that were not explicitly approved by Sonova AG are not permitted. Such changes may damage your ear or the hearing aid.
Do not use the hearing aids and charging accessories in explosive areas (mines or industrial areas with danger of explosions, oxygen rich environments or areas
49
50
where ammable anesthetics are handled) or where electronic equipment is prohibited.
If you feel pain in or behind your ear, if it is inamed or if skin irritation and accelerated accumulations of earwax occur, please check with your hearing care professional or physician.
In very rare cases, the dome can remain in your ear canal when removing the hearing tube from the ear. In the unlikely case that the dome does get stuck in your ear canal, it is strongly recommended to see a physician for safe removal.
Hearing programs in the directional microphone mode reduce background noises. Please be aware that warning signals or noises coming from behind, e. g. cars, are partially or entirely suppressed.
This hearing aid is not for children below 36 months. It contains small parts that can cause choking, if swallowed by children. Keep out of reach of children, individuals with cognitive impairment and pets. If swallowed, consult a physician or hospital immediately.
51
52
Keep the Charger Case out of reach of children, individuals with cognitive impairment and pets. If the drying capsule is swallowed, consult a physician or hospital immediately.
Only authorized personnel are allowed to open the Power Pack due to possible electrical hazard.
Do not make a wire connection from your hearing aid to any external audio sources like radio etc. That could cause injuries on your body (electric shock).
Do not cover the whole Charger Case or Mini Charger while charging, e.g. with a cloth etc.
The following is only applicable for persons with active implantable medical devices (i.e. pacemakers, debrillators, etc.):
• Keep the wireless hearing aid at least 15 cm
(6 inches) away from the active implant. If you experience any interference, do not use the wireless hearing aids and contact the manufacturer of the active implant. Please, note that interference can also be caused by power lines, electrostatic discharge, airport metal detectors etc.
• Keep magnets (i.e.
EasyPhone magnet, etc.) at least 15 cm (6 inches) away from the active implant.
• If using a Phonak wireless
accessory, consult the chapter “Important safety information” in your wireless accessory user guide.
Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
Use of accessories,
transducers and cables other than those specied or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.
Portable RF
communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the hearing aid(s), including cables specied by the manufacturer.
Otherwise, degradation of
the performance of this equipment could result.
The USB port of the
charger is to be used for the described purpose only.
For charger, use only
EN60950 and/or EN60601-1 certied equipment with a output rating of 5 VDC. Min. 500 mA.
Do not insert the adapter
of the power supply alone into electrical outlets because this could result in an electric shock.
Hearing aids should not be
tted with domes / wax protection systems when used by clients with perforated eardrums, inamed ear canals or otherwise exposed middle ear cavities. In these cases, we recommend the use of a classic earmold.
In the unlikely case that
any part of this product should remain in the ear canal, it is strongly recommended to see a physician for safe removal.
53
54
18.2 Information on product safety
Phonak hearing aids are water resistant and not waterproof. They are designed to withstand normal activities and occasional accidental exposure to extreme conditions. Never immerse your hearing aid in water! Phonak hearing aids are not specically designed for extended periods of water submersion on a continual basis, that is worn in activities such as swimming or bathing. Always remove your hearing aid before these activities, as the hearing aid contains sensitive electronic parts.
Protect your hearing aid from heat (never leave near a window or in the car). Never use a microwave or other heating devices to dry your hearing aid (due to risk of re or explosion). Ask your hearing care professional about suitable drying methods.
The dome should be changed every three months or when it becomes sti or brittle. This is to prevent the dome from detaching from the tube spout during insertion into or removal from the ear.
55
56
Do not drop your hearing
aid! Dropping onto a hard surface can damage your hearing aid.
Store your hearing aid in
the charger if you are not using it for a long period of time.
Special medical or dental examination including radiation described below, may adversely aect the correct functioning of your hearing aids. Remove and keep them outside the examination room/area before undergoing:
• Medical or dental examination with X-ray (also CT scan).
• Medical examinations with MRI/NMRI scans, generating magnetic elds. Hearing aids don’t need to be removed when passing security gates (airports etc.). If X-ray is used at all, it will be in very low doses, and will not aect the hearing aids.
The hearing aids have to be dry before charging. Otherwise the charging reliability cannot be guaranteed.
Both your hearing aid(s) and Power Pack contain lithium-ion batteries with a Watt hour rating <20 Wh which have been tested
according to UN 38.3 of the Only use approved chargers and Power Pack described in this user guide for charging your hearing aid(s), otherwise the devices may be damaged.
57
58
“UN Manual of Tests and
Criteria” and should be
shipped in accordance with
all the rules and regulations
on the safe shipment of
lithium-ion batteries.
Notes
Your hearing care professional:
Manufacturer:
Sonova AG Laubisrütistrasse 28 CH-8712 Stäfa Switzerland www.phonak.com
029-0477-02/V1.00/2017-01/FO © Sonova AG All rights reserved
59
Loading...