The Phoenix R200 is a compact, energy efficient LGR dehumidifier that removes 125 pints per day (AHAM) while drawing only 8.3 amps of electricity. The R200 outperforms larger competitive dehumidifiers by removing more water, providing larger grain depression and consuming less power. The proven LGR design is surrounded by a durable roto­molded high impact plastic to create a dehumidifier that is smaller and lighter than competitive units.
The Phoenix R200 LGR Dehumidifier
Patented Bypass Technology - Increased performance over a wide temperature range.
Capacity - The Phoenix R200 removes 125 pints per day at AHAM (80°F/60%RH).
Energy Efficiency - Draws only 8.3 amps and removes 5.2 pints/kWh.
Compact Design - Smaller, 20”x20”x33.5”, and only 105 lbs.
Motorized Impeller - 325 CFM; Faster drying and superior
static pressure for ducting.
More Grain Depression - Drier air from an LGR finishes jobs quicker versus a conventional refrigerant dehumidifier.
Focused Airflow - Patent focused outlet directs air downward across the wet surface.
Multiple Ducting Options - 12” intake, 10” exhaust.
Plastic Housing - Rugged roto-molded housing.
Solid State Controls - Easy to read and operate.
Protected Condensate Hose - Located under the top cover. Quick connect, cannot catch or be damaged on obstructions.
Telescoping Handle - A heavy-duty retractable handle for ease
of transport and reduces space for storage and stacking.
Recessed 12” Wheels - Allows greater maneuverability on the job site and efficient storage. Rolls over obstacles with ease.
Pleated Media Air Filter - A 12”x12”x1” MERV-11 filter is standard.
Stacking/Nesting - Reduces space for ease of stacking and storage.
Specifications subject to change without notice.
In addition to the performance benefits and compact size, the R200 has patented bypass technology, increased airflow, multiple ducting options, and a pleated media filter. The R200 is the latest member of the Phoenix line of LGR dehumidifiers; the most effective and versatile drying devices made.
Patented
BYPASS
Phoenix R200
Part No. 4027000 Patent 7,246,503
7,281,389 7,540,166
1
www.UsePhoenix.com • sales@UsePhoenix.comToll-Free 1-800-533-7533
TS-391
09/13
Table of Contents
Introduction ...............................................................1
1. Safety Certifications ..............................................2
2. Specifications .......................................................2
3. Operation ............................................................2
3.1 Transporting ...................................................2
3.2 Electrical Requirements ..................................2
3.3 Condensate Removal ......................................3
3.4 Ducting ..........................................................3
3.5 Defrost Cycle .................................................3
3.6 Power Button .................................................3
3.7 Purge Button ..................................................3
3.8 Hour Meter ....................................................3
3.9 Hours Button .................................................3
3.10 Defrost Light ................................................4
3.11 Bypass Control .............................................4
4. Maintenance ........................................................4
4.1 Air Filter .........................................................4
4.2 Storage .........................................................4
5. Service ................................................................4
5.1 Technical Description ......................................4
5.2 Troubleshooting ..............................................5
5.3 Air Mover .......................................................6
5.4 Thermistor .....................................................6
5.5 Condensate Pump ..........................................6
5.6 Float Safety Switch .........................................6
6. Options & Accessories ..........................................7
7. Wiring Diagram ....................................................7
8. Service Parts .......................................................8
9. Warranty ..............................................................9
1 Safety Certifications
The Phoenix R200 conforms to standards ANSI/UL 474
and CSA C22.2 No.92.
2 Specifications
Part No. 4027000
Power 8.3 amps, 120 VAC, Grounded
Water 125 pints/day @ AHAM (80°F, 60%) Removal 26 gal/day maximum @ saturation
Blower 325 CFM without external ducting
300 CFM @ .15 IWG external static
Refrigerant 1 lb, 10 oz. R-410A Charge
Operating 33°F to 110°F Range
Filters: 12” x 12” x 1” Pleated Media MERV-11
Duct Intake – 12” Flex-Duct Options Outlet – 10” Lay-Flat
Warranty Five years;
1st year 100% of Parts and Labor 2nd-5th year 100% of sealed refrigeration system parts.
Dimensions
Unit Shipping Width 20” 21” Height 33.5” 35.25” Depth 20” 21” Weight 105 lbs 115 lbs
Patent - 7,246,503 7,281,389 7,540,166
Read the operation and maintenance instructions carefully before using this unit. Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix R200 dehumidifier.
• It is designed to be used INDOORS ONLY.
• If used in a wet area, plug it into a GROUND FAULT
INTERRUPTER.
DO NOT use the Phoenix R200 as a bench or table.
• It must always be used in the upright position.
3 Operation
Place dehumidifier inside structure, place condensate hose into a drain, or a large water tight container, and turn on. To decrease drying times, make sure all windows and doors are closed to the outside and seal off the affected wet areas from unaffected areas.
Optimum performance will be observed
between the temperatures of 70°F and
95°F.
3.1 Transporting
The Phoenix R200 features a high impact roto-molded housing with 12” recessed wheels and a telescoping handle. The rugged roto-molded housing protects the dehumidifier from damage. The 12” wheels provide greater maneuverability and roll over obstacles with ease. The telescoping handle and recessed wheels create a
2
www.UsePhoenix.com • sales@UsePhoenix.comToll-Free 1-800-533-7533
Figure 1: Stacked Phoenix R200
compact dehumidifier for improved storage and transport. To operate the telescoping handle, pull out the lever to release the lock and lift the handle until it locks in the up position. Repeat to lock the handle in the down position. More compact storage can be achieved by stacking the units two high. The wheels of the unit ‘nest’ in the indentations of the bottom unit to provide stability, see figure 1. It is recommended the units are properly secured for transport. The Phoenix R200 must always be upright when transported by vehicle. It may be tipped onto its handle and back for loading and moving by hand.
Figure 2: Phoenix R200 control board.
3.2 Electrical Requirements
The Phoenix R200 plugs into a common grounded outlet on a 15 amp circuit. It draws 8.3 amps at 80°F, 60% RH. If used in a wet area, a ground fault interrupter (GFI) is required. If an extension cord is required, it must have a minimum of 14 gauge conductors if 25 feet long or less and 12 gauge conductors if greater than 25 feet long.
3.3 Condensate Removal
The Phoenix R200 is equipped with an internal condensate pump to remove the water that is condensed during dehumidification. This pump allows the condensate to be pumped 20 feet above the unit with the attached hose. If the condensate must be pumped more than 20 feet above the unit, a relay pump must be added. The condensate pump automatically purges for 20 seconds every eight minutes. Use the PURGE button to empty reservoir. If the condensate level rises in the reservoir to a critical level a back-up float switch will activate the pump-out for up to 1 minute. If the water in the reservoir fails to be evacuated, the safety switch will turn off the compressor.
3.4 Ducting
A wire duct collar is supplied to allow 10” lay-flat duct to be attached to the Phoenix R200 outlet. Lay-flat plastic ducting is available (see accessories in section 6). Attach ducting to the wire duct collar by inserting the plastic duct end through the collar center and rolling the duct end outward to overlap the outside of the collar. The duct and collar may then be quickly attached to the Phoenix R200 by snapping the collar over the four plastic exhaust tabs.
If the R200 is located in the unaffected area, the intake can be ducted with 12” flex duct (see accessories in section 6). Attach the flex duct to the top cover by hooking the spiral wire under the four tabs. Tape the duct to the top cover for a complete seal.
3.5 Defrost Cycle
If the low side refrigerant temperature drops below the defrost set point, due to excessive frost formation on the evaporator coil, the thermistor activates the solid-state control and the defrost light. The control cycles the com­pressor “off” and “on” by the thermistor temperature mea­surement. The air mover will continue to run, causing air to flow through the evaporator coil and melt the ice when
the compressor is off. When the air temperature and/or humidity increases, the evaporator temperature will rise and the thermistor will end the defrost cycle at the defrost set point.
3.6 POWER Button
Press the POWER button to turn the dehumidifier “on” or “off”. When starting the dehumidifier the display will show the accumulated hours. Press the POWER button again to turn the dehumidifier off. The display will also power off.
3.7 PURGE Button
During normal operation the pump automatically cycles every four minutes. Press the PURGE button to remove condensate manually from the reservoir. There are three
ways to manually remove water from the reservoir:
1. Press the PURGE button once and the pump will run for 20 seconds
2. Press and hold the PURGE button and the pump will run for up to 30 seconds
3. Press the PURGE button while the dehumidifier is plugged in but powered off and the pump will run for 30 seconds.
Always manually purge the water reservoir before transport or storage. Turn off the power and allow the plugged in dehumidifier to rest 15 minutes before the final purge.
3.8 Hour Meter
The digital hour meter displays the amount of time the dehumidifier has been turned on to the tenth of an hour. The hour meter continuously cycles between total machine hours and job hours every 3 seconds. Hours are stored in memory even when the unit is unplugged. The previous totals will be displayed next time the unit is powered on.
3.9 HOURS Button
Pressing the HOURS button displays the hour meter when the unit is turned off but plugged into power. To reset job hours, press and hold the HOURS button for 5 seconds when the unit is operating.
3
www.UsePhoenix.com • sales@UsePhoenix.comToll-Free 1-800-533-7533