Phoenix Pro-V Series Operation Manual

Pro-V Series
With Modulating FAN control
Phoenix Manufacturing Inc.
Mode of Operation
Programmable Digital Thermostats
Index
Content Page
INSTALLATION........................................................................................................ 3
MOUNTING ON ELECTRIC BOX .............................................................................. 3
M
OUNTING FRONT COVER.................................................................................... 3
W
IRING EXAMPLE ............................................................................................... 3
OPERATION ........................................................................................................... 4
S
ETTING CLOCK………………………………………………………………………. 7
S
ETTING PROGRAM FUNCTION ………………………………………………………. 7
Fan Speed
Temperature Set
Set Time, Date, Schedules
On / Off
1
3655 E. Roeser Rd. – Phoenix, AZ 85040
602-437-1034 - info@evapcool.com
01-999-2578
#
Item
Description
1
LCD
Display temperature and working status.
2
MODE button
Access to user and engineer menu and f or set ting confirmation or change ℃/℉ unit if press for over 3 sec.
3
FAN button
Toggle to change Fan mode: Auto or cont. Low/ Hi
4
UP & DOWN buttons
Increase & decrease setting or previous/next item
5
SET button
Setting for schedules and Timers
6
On/Off button
Turn on/ off t hermostat
7
Set-point icons
Displaying set-point temperature while it is flashing
8
Fan icons
Indicate Fan status
9
Snow Flake icon
Indicate working on Cooling mode; Flashing = Pre-wet
10
Hot spring icon
Indicate working on Heating mode (NA)
11
Flow icon
Indicate working on ventilating mode
12
Gear icon
Indicate cooler is ON
13
Clock
Indicate current System ON or OFF was enabled by real time Timer.
14
Sleep
(NA)
15
Moon Sign
Indicating room is unoccupied or Vacat ion Mode
16
Outdoor icon
Indicating door/ window is open(NA)
17
Cover screw
Screw to tighten back cover with front cover
18
Back plate
Plate for mounting on electric box
19
Wiring terminal blocks
Terminals for wiring
20
Mounting holes
Holes for mounting on electric box
21
Clock
Display time
22
Schedule number
Current Schedule running or setting
23
Day
Current day of Sunday ~ Saturday or setting
24
Sun
Indicate Drain is undergoing now
Front view Back view
2
Installation
Note: This unit requires at least 6 c onductor thermostat wire. 18-6 is recommended.
Mounting on electric box
1. Separate back plate from the controller by loosing the cover screw;
2. Align the mounting holes on the screw holes of the electric box(applicable to 65x65 or US standard box);
3. Fix the back plate on the electric box by tightening the back plate screws. Suggest using Philips drive “truss head” or “washer head” #6-32x 3/4” (20mm).
4. DO NOT let the bolt head rise above the wall of mounting holes of back plate. It might cause the short circuit of the controller.
Mounting front cover
1. Lock front cover on the back plate by tightening the cover screw underneath with Philips head screw driver.
Wiring Example
All wires coming from electric box must be inserted above the retainers of respective terminal block before tightening the captive screws
3