Phoenix MSD 50HPS-120, MSD 100HPS-120, MSD 70HPS-120, MSD 150HPS-120 Installation Instructions And Parts List

7
PHOENIX
INSTALLATION INSTRUCTIONS AND REPAIR PARTS LIST FOR
HIGH PRESSURE SODIUM INTEGRAL BALLAST FLOODLIGHTS
120 VOLTS, 50-150 WATTS
LAMPING
Before lamping or re-lamping, make sure t hat power is turned off to the fixture.
To gain access to the lamp compartment, loosen 10 captive screws (Item 12) in the removable cover (Item 23). (Cover nearest 1/2 in. NPSI ho le). DO NOT REMOVE BARRIER (Item 27). DO NOT REMOVE THE FIXED COVER (Item 22) WHICH HAS THE LAMP SOCKET ATTACHED TO IT.
Screw lamp into socket. Reinstall removable cover (Item 23) and tighten 10 screws (Item 12) to 15 in-lbs. The fixt ure can be mounted and electric power connected.
CAUTION
MOUNTING
Vertical or horizontal mounting kits must be ordered with fixture. Insert one 1/2 inch (12mm) stainless steel bolt through the mounting hole provided in the mounting bracket and secure with appropriate lock washer and nut on t he oth er side of the mounting fixture. When mounting on a maximum 1-3/4" OD pole or mast, a 1/4 inch (6mm) stainless steel UĀ­bolt may be inserted in the holes provided in the bracket and
1. Operate fixture ONLY with PRO PER lamp. The internal ballast in each fixture is designed to accommodate a specific wattage lamp. See LAMP RECOMMENDATIONS.
2. If the lamp fails, replace lamp or disconnect primary power to fixture within two weeks at the most. Otherwise, permanent damage to electrical components may resu lt fro m high voltage pulses unique to High Pressure Sodium circu its.
3. Use protective gloves and safety eyeglasses when replacing lamps.
If outer glass bulb is broken, turn off lamp and replace it promptly to avoid exposure to ultraviolet energy. Even with lamp outer glass enclosure broken, the arc tube may continue to fire.
Fixture Model No.
MSD-120-50HPS MSD-120-70HPS
MSD-120-100HPS
LAMP RECOMMENDATIONS
Wattage
50 70
100
Phoenix Part No.
4211300 4212600 4212700
the fixture secured with appropriate lock washers and nuts. NOTE: Mounting hardware isn't provided with fixture.
MSD-120-150HPS
150
N5488100F-1
4212800
HORIZONTAL MOUNTING-USE KIT NO. 1090170 VERTICAL MOUNTING-USE KIT NO. 1090160
REPAIR PARTS LIST
1 2
2 1
3 1
4 3
5 1
6 1
8 1
9 2
4
2
1
3
3
3
3
1
1
2
1
1
1
1
1
1
ITEM QTY. DESCRIPTION
End Cover Gasket Socket Insulator Black EPDM Grommet Spacer Reflector Bracket For Capacitor & Ignitor
10 11 12 15 16 17
7
20 S.S. Thread Forming Type B, Captive Screw, #8 x 1
Mounting Bracket Vertical Mount ing
1
Mounting Bracket Horizontal M ounting Cable Assembly Threaded Rod S.S. Hex Head Close-Acorn Nut, 6-32 S.S. Slotted Pan Head Machine Scr ew 6-32 x .25
S.S. Green Nut, hex 10 -32 Threaded Rod S.S. Hex Nut, 6-32
PART NUMBER
5005600 4052600 5005500 7523400 2693901 2310600 1090160
1090170 7508500 2694601 6220200 6007700 6022300 6203900 2694602
6201700 18 19
20 21
22
23 24 25
26 27 28
S.S. Split Lockwasher, #6 Cable Tie Capacitor-Includes (3) Cable Ties, I tem 19
50 Watt - (MSD 120 - 50 HPS) 70 Watt - (MSD 120 - 70 HPS) 100 Watt - (MSD 120 - 100 HPS)
1
150 Watt - (MSD 120 - 150 HPS) Lamp Socket Fixed Cover Kit (Lamp Socket Side) Including: Reflector, Gasket, and Label
1
(Preassembled), (10) #8 x 1" Lg. Screws Removable Cover Kit Including: Reflector and G as k et (Preassembled), (10) #8 x 1"
1
Lg. Screws Glass Kit With (2) Gaskets Reflector - Includes (1) Gasket, Item 1 Ballast & Ignitor - Includes (3) Cable Ties, Item 19
50 Watt - (MSD 120 - 50 HPS) 70 Watt - (MSD 120 - 70 HPS) 100 Watt - (MSD 120 - 100 HPS)
1
150 Watt - (MSD 120 - 150 HPS) Barrier Screw, Thread Forming T ype B #8 x 3/8
6312900
4052200
1076100
1076200
1076300
1076400
4503700
1074900
1075000
1075100
2693901
1076800
1076900
1077000
1077100
2701700
6021000 29 30 31 32
Nut U-Type #8 Washer, Flat Washer, Terminal Washer, Lock, External Toothed #10
N5488100F-2
6241500
6302700
6321100
6310400