– READ AND SAVE THESE INSTRUCTIONS –
The FireBIRD Compact 20 portable electric heater features multiple power receptacles for connection to common 120VAC outlets. The Compact 20 can output up to 20,000 Btu of clean, safe heat at 250 CFM. The Compact 20’s remote thermostat provides a means to control the temperature in the drying chamber, while its internal temperature cutout ensures safe operation.
The Phoenix FireBIRD Compact 20
• Listed by ETL to UL Safety Standards
• 15 Amp Operation at 120VAC up to 4 independent circuits (20,000 Btu)
• Remote Thermostat with 25’ connecting wire (included with unit)
• Standard MERV-11 air filter included
• Multiple ducting options
• 8” Outlet Duct, 8” Inlet Duct Optional
• Stainless Steel Cabinet
• Double-Walled, Screened Enclosure for heating elements
• Automatic Internal 140°F Safety Thermal Cutout
• Stackable for easy storage and transportation
1.800.533.7533
Phoenix FireBIRD Compact 20 PN 4033450
WISCONSIN
USEPHOENIX.COM
1
Specifications subject to change without notice.
TS-786
04/19 Rev. C
Table of Contents
Introduction ................................................................................1
1. Specifications .....................................................................3
2. Operation .............................................................................3
2.1 Transporting ................................................................3
2.2 Electrical Requirements ............................................3
2.3 Ducting ..........................................................................4
2.4 Control Panel ..............................................................4
3. Maintenance .......................................................................5
3.1 Air Filter .......................................................................5
4. Service ................................................................................5
4.1 Technical Description ................................................5
4.2 Troubleshooting ..........................................................5
5. Options and Accessories ..................................................5
6. Wiring Diagram .................................................................6
7. Service Parts .....................................................................7
Warranty .............................................................................8
Serial No. ___________________________
Purchase Date ______/______/_____
Dealer’s Name ___________________________________
Read the operation and maintenance instructions carefully before using this unit. Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix FireBIRD Compact 20.
TO PROVIDE CONTINUED PROTECTION AGAINST RISK OF ELECTRIC SHOCK, CONNECT TO PROPERLY GROUNDED OUTLETS ONLY.
POWER CORDS MUST BE 12 GA MINIMUM AT 25 FT OR LESS, GREATER THAN 12 GA AT LONGER LENGTHS, AND MUST HAVE A THREE-BLADE GROUNDING-TYPE PLUG.
ATTENTION
POUR ASSURER UNE PROTECTION CONTINUE CONTRE LES ÉLECTROCUTIONS, NE BRANCHEZ QU’À DES PRISES DE COURANT MISES À LA TERRE CORRECTEMENT.
LE CORDON D’ALIMENTATION DOIT ÊTRE AU MOINS DE CALIBRE 12 GA (POUR LES LONGUEURS DE 25 PIEDS ET MOINS), DE PLUS DE 12 GA POUR DES LONGUEURS PLUS LONGUES ET CONTENIR UNE FICHE DE MISE À LA TERRE À TROIS FILS.IMPORTANT INSTRUCTIONS
• Read all instructions before using this heater.
• DO NOT OPERATE near children or invalids.
• This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this heater. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 36” (.91 m) from the front of the heater and keep them away from the sides and rear.
• For temporary use only, not for comfort heat. See NFPA 70 Article 590.
• Always unplug unit when not in use.
• DO NOT OPERATE with damaged cord, plug, or after unit malfunctions, has been dropped or damaged in any manner. Return to authorized service facility for examination or repair.
• Unit Intended for INDOOR USE ONLY; DO NOT USE OUTDOORS.
• This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. Never locate heater where it may fall into a bathtub or other water container.
• DO NOT run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
• To disconnect device, turn controls off, then remove plug from outlet.
• Connect ONLY to properly grounded GFCI outlets.
• DO NOT insert or allow foreign objects to enter any ventilation or exhaust openings as this may cause an ELECTRIC SHOCK or FIRE, or damage the heater.
• To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, such as a bed, where openings may become blocked.
• Device has hot and arcing or sparking parts inside. Do not use in areas where gasoline, paint, or flammable liquids are used or stored.
• Use device only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
• Cords used for 120V service shall be No. 12 AWG minimum size rated not less than 1440 Watts.
SAVE THESE INSTRUCTIONS CONSIGNES IMPORTANTES
• Lisez les consignes en entier avant d’utiliser cet appareil de chauffage.
• ÉVITEZ TOUTE UTILISATION lorsqu’en présence d’enfants ou de personnes handicapées.
• Cet appareil devient CHAUD lorsqu’en fonction. Pour éviter les brûlures, ne laissez pas la peau nue entrer en contact avec les surfaces chaudes. Lorsque disponibles, utilisez les poignées pour déplacer cet appareil. Prévoyez un champ de dégagement pour les matériaux
1.800.533.7533
USEPHOENIX.COM
2
combustibles tels les meubles, oreillers, literies, papiers, vêtements et rideaux d’au moins 36’’ (0,91 m) de distance d’avec la façade de l’appareil de chauffage et maintenez-les bien éloignés des côtés et de l’arrière.
• Conçu pour utilisation temporaire seulement et non comme chauffage d’appoint. Voir l’article 590, normes NFPA 70.
• Débranchez toujours l’unité après utilisation.
• N’UTILISEZ PAS un appareil présentant un cordon ou un branchement endommagé ou suivant tout dysfonctionnement, chute ou endommagement d’une quelconque façon. Retournez plutôt l’appareil à un centre de service autorisé pour inspection ou réparation.
• Cette unité est prévue pour une UTILISATION EN INTÉRIEUR SEULEMENT; NE L’UTILISEZ PAS À L’EXTÉRIEUR.
• Cet appareil de chauffage n’est pas conçu pour une utilisation dans les salles de bain, les salles de lavage ou autres espaces intérieurs similaires. Ne placez jamais cet appareil en milieu humide où il pourrait tomber dans une baignoire ou autre réceptacle contenant de l’eau.
• ÉVITEZ de glisser le cordon d’alimentation sous un tapis. Ne recouvrez pas le cordon d’alimentation avec des carpettes, chemins de plancher ou recouvrements similaires. Évitez de glisser le cordon d’alimentation sous des meubles ou appareils. Assurez-vous que le cordon se trouve éloigné des zones de passage ou là où il pourrait créer un trébuchement.
• Pour débrancher l’appareil, fermez les boutons de contrôle et retirez la fiche de la prise de courant.
• Ne branchez cet appareil qu’à une prise de courant avec disjoncteur de fuite à la terre (DDFT).
• N’insérez AUCUN corps étranger dans la ventilation ou les ouvertures d’échappement; cela peut créer une DÉCHARGE ÉLECTRIQUE, un INCENDIE ou endommager l’appareil de chauffage.
• En prévention d’un éventuel incendie, ne bloquez aucune entrée d’air ou échappement de quelque façon que ce soit. Évitez d’utiliser sur les surfaces souples telles un lit où les entrées risquent d’être bloquées.
• L’appareil comporte des pièces chaudes pouvant produire des arcs électriques (étincelles). Ne pas utiliser là où de l’essence, de la peinture et des liquides inflammables sont utilisés ou entreposés.
• Utilisez cet appareil uniquement aux fins décrites dans le manuel. Toute utilisation non recommandée par le fabricant risque de créer un incendie, une décharge électrique ou des blessures corporelles.
• Les rallonges utilisées pour un branchement en 120 V doivent être au moins de calibre no 12 AWG et être approuvées pour 1 440 watts au minimum.
CONSERVEZ CES CONSIGNES.
1 Specifications
Part No. 4033450
Power Blower Circuit: 1 Amp at 120VAC 60Hz, 1 Phase
120VAC 60Hz, 1 Phase Heater Circuits (up to 4):
12 Amp / circuit = 17°F temperature rise/ circuit: 5,000 Btu
Maximum Heat: 20,000 Btu with 70°F Maximum Temperature Rise at 250 CFM
Blower 250 CFM
Filters Pleated Media MERV-11
Duct Options Outlet – 8” Flex-Duct
Warranty 1 year 100% of Parts and Labor
Dimensions
Unit Shipping Width 13” 17”
Height 12.5” 17” Depth 26” 30” Weight 35 lb 42 lb
2 Operation
2.1 Transporting
The Phoenix FireBIRD Compact 20 must always be upright when transported by vehicle. The Compact 20 is equipped with rubber corners to permit stacking for storage. If units are transported, they must be secured with restraining straps to prevent damage and possible injury.
2.2 Electrical Requirements
The Phoenix FireBIRD Compact 20 requires a 120VAC outlet to power the onboard blower, control and 1st heater circuit. Three aditional heating elements are separately powered by additional cords and receptacles.
120VAC heating elements each require cord connection to appropriate receptacles rated at 15A or more. One cord and receptacle are required per heating element. Power cords should be appropriately sized. POWER CORDS MUST BE 12 GA MINIMUM AT 25 FT OR LESS, GREATER THAN 12 GA AT LONGER LENGTHS, AND MUST HAVE A THREE­BLADE GROUNDING-TYPE PLUG. An adapter is available for