Type 50A Model, 9, 10, 11, 14, & 17 120V (AC/DC)
Plug power cord into suitable 120 Volt AC or DC power
source.
Type 50A Model 7 & 15, 240V (AC Only)
Plug power cord into suitable 240 Volt AC (Only) power
source.*
ELECTRODE HOLDING
1. Open lid of box and allow approximately 20 minutes
warm-up to drive out any retained moisture.
2. Place only dry electrodes within box. Keep lid closed
but unlatched while plugged into powered receptacle.
Heating Element: Ring Type, 350 Watts, 240 Volts
ELECTRODE STORAGE
3. When your job is done, the oven should remain connected to its power source. If it becomes necessary to
disconnect from power, keep the lid closed and latched
to provide sealed storage of unused electrodes.
optimum temperature control. The sealed thermostat is
not adjustable, but easily replaced if it fails. Average
stabilized temperature of the oven is 300°F with a full
load (average 250°F empty). A parts list and wiring diagrams are printed on the reverse side for your convenience.
*Warranty is void if used with D.C. power source
Three Wire Grounded Circuit:
Temperature: 300°F Average
®
TYPE 50A MODEL 15
240 Volts AC (Only) *
(stabilized temperature)
*Caution* - To avoid oven damage, never place oven in contact with welding current.
All wiring should be done by licensed electricians in accordance with State & Local codes plus NEC (National Electric
Code) Standards. Improper installation or use may result in serious injury. Always remove oven from power source
before troubleshooting or repairing.
II.TROUBLESHOOTING - TYPE 50 OVENS
OVEN FAILS TO OPERATE - NO HEAT
1. If oven will not heat, check power supply.
2. Check plug at outer end of power cord. Check complete power cord for continuity. If defective, replace cord
assembly.
3. Disconnect wires from heating element and check
heating element for continuity (access through top of
**CAUTION**
oven). If defective, replace elements.
defective, replace thermostat.
OVEN OPERATES - OVERHEATS
Fails To Operate - No Heat).
Item
AC Only
AC Only
Oven
Oven
50A WIRING DIAGRAM50A 240V WIRING DIAGRAM
III.TYPE 50A REPAIR PARTS ILLUSTRATION
Part Numbers
No.Description120V240V
Qty/
Qty/
WHEN ORDERING, SPECIFY PART NUMBER, DESCRIPTION, QUANTITY AND THE
FOLLOWING NAMEPLATE DATA: "TYPE,
MODEL NO. AND VOLTAGE".
1 Lid Assembly1NLA1NLA
1A Lid Gasket (not shown)1NLA1NLA
2 Pull Catch Loop1720140017201400
3 Compartment Divider2260100022601000
4 Heating Element 1
5 Heating Element Clamp Assembly1
6 Thermostat Kit1125706111257061
8 Cord with Plug, remove plug for 240V19 Strain Relief Bushing (7P-2)11
Gasket Kit Includes
10 Gasket Plate11
11 Gasket 11
Phoenix International, Inc. warrants its products against defects in material and workmanship. The company will, at its discretion, repair or replace any properly installed Phoenix
International manufactured product which fails under normal operating conditions within
one year from date of receipt. Contact the factory for return authorization before returning
the product to Phoenix International freight prepaid. If our inspection confirms that the
product is defective under terms of this warranty, it will be repaired/ replaced and returned
freight prepaid.
4402200
NLA
12571231257123
12571221257122
NLANLA
1
4401700
1
This warranty applies only to Products sold by Phoenix International, Inc. and specifically excludes installation or de-installation labor, transportation, or equipment of another
manufacturer used in conjunction with Phoenix International products. No other warranty,
expressed or implied, exists beyond this warranty declaration.
Phoenix constantly strives to improve its products and therefore reserves the right to
change design, materials, and specifications without notice.
*Operation on Direct Current will damage oven and void warranty
**Average Stabilized Temperature @ 70°F Ambient Temperature
120V AC* @ 350 watts w/ 10' Grounded HD cord
Electrode Stabilization Ovens General Information:
Insulation: 1" (2.5cm) Glass Fiber Batt
Chamber Size: 6" x 6" x 18" (15 x 15 x 46cm)
Capacity: 50 lb. (22.7kg) of 18" (45.7cm) electrodes also accepts 10"
(25.4cm), 12" (30.5cm), & 14" (36cm)
300°F (149°C) Preset
Sealed Thermostat
300°F (149°C) Constant
Input, No Thermostat
®
Net Weight & Dimensions: 9" x 9" x 21" (22 x 24 x 54cm) 29 lbs. (13Kg)
Ship Weight & Dimensions: 10" x 10" x 24" (25 x 25 x 54cm) 32 lbs.
(14.5Kg)
*Caution* - To avoid oven damage, never place oven in contact with welding current.
-
ing contaminated electrodes. They are designed to accept
electrodes in 100% useable condition and to maintain that
-
lization, oven should be hot when loaded and kept “on line”
oven cools. We recommend removal of electrodes at shift
end and storage of same consumables in suitable larger
In the absence of detailed storage information from your
-
ations be sure to contact your electrode manufacturer for
II.OVEN TYPE DESCRIPTION
N5610244D-3
Wiring
Check type and voltage on nameplate.
Types 50B 120/240V AC only models utilize a tamperproof
sealed thermostat, providing a 300°F average stabilized load
temperature.
Type 50C/120V AC/CD (Non-Thermostat model), utilizes
constant heat input, providing a 300°F average stabilized
load temperature.
Note: All current 50B ovens rated at 120 volts have a Model
1 designation, 240 volt ovens have Model 2 designation.
Electrode Storage
These ovens are not to be used for rebaking or recondition
condition until consumed at the job site. For optimum stabi
as long as electrodes are being stored.
Type 50 series ovens are not airtight and electrodes stored
within will start absorbing ambient moisture as soon as the
holding ovens until reissued.
Grounding
1. The 120 volt ovens have a three blade plug cap with
grounding prong (NEMA 5-15P) attached to a 10 foot power
supply cord. When used with a grounded receptacle, these
ovens meet all local electrical code requirements and are
U.L. Listed.
2. The 240 volt ovens have a 10 foot power supply cord.
When used with a grounding plug cap and a grounded
receptacle, these ovens meet all local code requirements.
Electrode Holding
1. Open lid of oven and allow approximately 20 minutes
warm-up time to drive out any retained moisture.
2. Place only dry electrodes within oven. Keep lid closed but
unlatched while plugged into power receptacle.
Guide to Storage
electrode manufacturer, the "Revised Guide To Electrode
Storage" (available from Phoenix International, Inc.) may be
used as an indication of approximate temperatures for use
of the oven. For Specific information involving critical oper
complete information.
**CAUTION**
4. On type 50B ovens check thermostat for continuity at
-
1. Check thermostat operation as in number 5 (Oven Fails
N5610244D-5
All wiring should be done by licensed electricians in accordance with local codes. Improper installation or use may
result in serious injury. Always remove oven from power source before troubleshooting or repairing.
III.TROUBLESHOOTING - TYPE 50 OVENS
OVEN FAILS TO OPERATE - NO HEAT
1. If oven will not heat, check power supply.
ambient temperature (access through top of oven). If defec
2. Check plug at outer end of power cord. Check complete
power cord for continuity. If defective, replace cord assembly.
3. Disconnect wires from heating elements and check heat-
ing element for continuity (access through top of oven). If
defective, replace elements.
• One thermostat kit, No. 1257061 (Type 50B 120 & 240 volt
• One (1) 10 foot connection cord with cap & strain relief, No.
V.SUGGESTED SPARE PARTS TYPE 50B & 50C OVENS
N5610244D-9
Following quantities for each oven:*
• One heating element kit, No. 1257020 (Type 50B 120 &
240 volt models)
• One heating element kit, No. 1257071 (Type 50C 120 volt
models)
*For quantities of ovens exceeding 10, we suggest providing approximately 20% more of the above quantities of spares as sufficient for day to day
operation.
For overseas operation we suggest a minimum of 30% more for spares.
models)
1257120 (120 & 240 volt models).
Phoenix International, Inc. warrants its products against defects in material and
workmanship. The company will, at its discretion, repair or replace any properly installed Phoenix International manufactured product which fails under
normal operating conditions within one year from date of receipt. Contact the
factory for return authorization before returning the product to Phoenix
International freight prepaid. If our inspection confirms that the product is
defective under terms of this warranty, it will be repaired/ replaced and returned
freight prepaid.
Phoenix International, Inc.
8711 West Port Avenue
Milwaukee, WI 53224 USA
Phone (414) 973-3400
Fax (414) 973-3210
www.phx-international.com
info@phx-international.com
This warranty applies only to Products sold by Phoenix International, Inc. and
specifically excludes installation or de-installation labor, transportation, or
equipment of another manufacturer used in conjunction with Phoenix
International products. No other warranty, expressed or implied, exists beyond
this warranty declaration.
Phoenix constantly strives to improve its products and therefore reserves the
right to change design, materials, and specifications without notice.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.