Low amp draw, balanced airflow characteristics and maximum velocity of 2700 FPM are what propel the Phoenix to rise above the competition.
The unique 1/3 horsepower design of the Phoenix Centrifugal Air Mover, coupled with a two-speed switch, allows the restoration technician to deliver the most airflow using the fewest amps.
Maximum amp draw on high speed is 2.8 amps. This drops to a mere 2.4 amps on low speed. It is now possible to fit as many as four Phoenix Centrifugal Air Movers onto a typical 15 amp household circuit. The Phoenix CAM is lightweight, stackable, has a power indicator lamp, large three-position switch, and superior cord management.
The Phoenix housing is durable, washable, and chemical resistant. It features multiple operating positions allowing it to be angled up from horizontal to 45° and 90°.
The Phoenix Centrifugal Air Mover
• 2-Speed 1/3 Horsepower Motor with automatic­reset thermal protection.
2.8 Amps on High Speed
2.4 Amps on Low Speed
• Maximum Velocities 2700 FPM
• Balanced Exhaust Airflow
• Directional Airflow Horizontal, 45° Angle, 90° Angle
• Durable, rugged, chemical resistant housing, fan wheel, and controls design.
• Operator interface conveniently located for easy access, featuring: power indicator lamp and large three-position switch.
• Phoenix exclusive Pilot Light and Sealed Switch are recessed to prevent damage.
• Ergonomic carry handle and power cord storage.
• Non-marking, anti-skid, rubber feet.
Phoenix Centrifugal Air Mover PN 4027508
Specifications subject to change without notice.
TS-479 Rev. A 7/08
1
www.usephoenix.com • sales@thermastor.comToll-Free 1-800-533-7533
Table of Contents
Introduction ...............................................................1
Centrifugal Air Mover Features and Benefits ...................1
1. Safety Information .................................................2
2. Specifications ........................................................3
3. Operating Instructions ...........................................3
4. Operator Panel Features .........................................4
4.1 Power Indication Lamp .....................................4
4.2 3-Position Drying Selector Switch ......................4
5. Maintenance .........................................................4
5.1 Servicing ........................................................4
5.2 Cleaning .........................................................4
6. Replacement Parts and Optional Accessories ...........4
7. Warranty ...............................................................5
Serial No.__________________________________
Purchase Date_____________________________
Dealer’s Name_____________________________
Read the operation and maintenance instructions carefully before using this unit. Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix 4027508.
1 Safety Information
When using any rotational electrical device basic precautions should always be followed, including the following:
CAUTION! For general ventilating use only. Do not use in environments containing hazardous or explosive materials and vapors.
• Do not operate the unit without the safety guards properly installed and secured. Do not operate the unit if the guards become damaged. Contact Therma-Stor for replacement parts.
• Always replace the guards as originally installed after servicing or cleaning the product.
• Never place your face, hands, or other susceptible body parts in the air stream, inlets, or outlet of this device.
• This fan is not a toy! Ensure children do not play with and do not have access to the equipment. Do not allow children to play with or near the unit or in its air flow.
• Do not use this fan with any solid-state speed control device.
• Do not operate unit with a cut or frayed power cord. Replace cord if it becomes damaged.
• Handle with care. Do not drop or throw the unit. The unit can be damaged under harsh treatment.
• Do not unplug the unit by pulling on the cord. Grasp the plug firmly and pull it out of the wall socket or power receptacle.
• Always use a grounded outlet.
• Never operate electrical equipment in standing water.
• Never operate with the safety grills removed. Personal injury may result.
• Do not stick your fingers or other objects through the safety grills.
• Do not restrict airflow to the unit. This may cause the unit to overheat.
• Unit should never be serviced or cleaned while it is plugged in.
• Make sure the unit is secure, stable and safe from falling over or falling down before operating.
• Do not sit or stand on the unit or use as a shelf.
• Do not leave device plugged in when not in use.
• Indoor use only. Do not expose to water or rain–store indoors.
• Use only as described in this manual.
• Use only Manufacturer’s recommended attachments. Contact Therma-Stor for proper repair instructions.
• Do not pull or carry it by the power cord, use cord as a handle, close doors on cord or pull cord around sharp edges.