Phoenix Stackable CAM Pro, 4030990 Owner's Manual

4201 LIEN RD. • MADISON, WI 53704
Phoenix Stackable CAM Pro - Centrifugal Air Mover
OWNER’S MANUAL
Installation, Operation & Service Instructions
– READ AND SAVE THESE INSTRUCTIONS –
The Phoenix Stackable CAM Pro offers all the great features of our proven CAM air movers, with the addition of an innovative stackable cabinet design. Featuring multiple contact points and interlocking side grills, the Phoenix Stackable CAM Pro can be stored safely and securely up to 4 units high, freeing up valuable space in your trucks and warehouses.
The Stackable CAM Pro features class-leading airflow and efficiency. Using a unique 1/3 horsepower motor design and proprietary blower technology, the Phoenix Stackables achieve 1050 CFM at over 2800 FPM with high static pressure, while using only 2.6 amps of electricity on high speed (2.0 amps on low). With it’s low amp draw and onboard GFCI, the Phoenix Stackable CAM Pro gives you maximum airflow on a circuit, allowing up to 4 CAMs on a standard 15 amp household circuit on high speed (or up to 6 on low speed). The Phoenix Stackable CAM housing is durable, washable, and chemical resistant. It features multiple operating positions allowing it to be aimed horizontally, vertically, or at 45°. And, like all Phoenix air movers, the Stackable CAM Pro is ETL Listed, UL Certified.
The Phoenix Stackable CAM Pro is also lightweight and properly balanced for easy handling. Other convenience features include a lighted cord for easier determination of power to the outlet and superior cord management for better handling, packing, and storage.
The Phoenix Stackable Centrifugal Air Mover Pro
• 2-Speed 1/3 Horsepower Motor
2.6 Amps on High Speed
2.0 Amps on Low Speed
• Maximum Velocities 2800 FPM
• Balanced Exhaust Airflow
• Directional Airflow Horizontal, 45° Angle, 90° Angle
• Durable, rugged, chemical resistant housing, fan wheel, and controls design.
• Operator interface conveniently located for easy access, featuring: power indicator lamp and large three-position switch.
• Ergonomic carry handle and power cord storage.
• Non-marking, anti-skid, rubber feet.
• 4 CAMs on a circuit on high
• 6 CAMs on a circuit on low
• 20% more CFM/Amp than our current industry leading CAM
• On-board duplex GFCI and circuit breaker
• Stacks up to 4 units high
*PN 4030980 is
pictured to demonstrate
stackability
1.800.533.7533
Phoenix Stackable Centrifugal Air Mover Pro PN 4030990
WISCONSIN
USEPHOENIX.COM
1
Specifications subject to change without notice.
TS-669
08/18 Rev. A
Table of Contents
Introduction ...............................................................................1
Centrifugal Air Mover Pro Features and Benefits .................1
1. Safety Information .............................................................2
2. Specifications .....................................................................3
3. Power Requirements .........................................................3
3.1 Daisy-Chaining ............................................................. 3
3.2 Recommended Use ....................................................4
4. Operating Instructions.......................................................4
5. Operator Panel Features ...................................................4
5.1 12 Amp Circuit Breaker ..............................................4
5.2 Power Indication Lamp ..............................................4
5.3 3-Position Drying Selector Switch .............................4
5.4 GFCI Protection ............................................................5
6. How to Stack .......................................................................5
7. Maintenance .......................................................................5
7.1 Servicing .......................................................................5
7.2 Cleaning ........................................................................5
8. Replacement Parts and Optional Accessories ..............5
9. Wiring Diagram ..................................................................6
Warranty ..............................................................................7
Serial No.__________________________________
Purchase Date_____________________________
Dealer’s Name_____________________________
Read the operation and maintenance instructions carefully before using this unit. Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix 4030990.
1 Safety Information
When using any rotational electrical device basic precautions should always be followed, including the following:
CAUTION! For general ventilating use only. Do not use in environments containing hazardous or explosive materials and vapors.
• Do not operate the unit without the safety guards properly installed and secured. Do not operate the unit if the guards become damaged. Contact Therma-Stor for replacement parts.
• Always replace the guards as originally installed after servicing or cleaning the product.
• Never place your face, hands, or other susceptible body parts in the air stream, inlets, or outlet of this device.
• This fan is not a toy! Ensure children do not play with and do not have access to the equipment. Do not allow children to play with or stand near the unit or in its air flow.
• Do not use this fan with any solid-state speed control device.
• Do not operate unit with a cut or frayed power cord. Replace cord if it becomes damaged.
• Handle with care. Do not drop or throw the unit. The unit can be damaged under harsh treatment.
• Do not unplug the unit by pulling on the cord. Grasp the plug firmly and pull it out of the wall socket or power receptacle.
• Always use a grounded outlet.
• Do not plug more than 9.3 amps total into the GFCI outlet.
• Check GFCI protection before each use by pushing “test” button. If operating properly, “reset” button will pop out.
• Never operate electrical equipment in standing water.
• Never operate with the safety grills removed. Personal injury may result.
• Do not stick your fingers or other objects through the safety grills.
• Do not restrict airflow to the unit. This may cause the unit to overheat.
• Unit should never be serviced or cleaned while it is plugged in.
• Make sure the unit is secure, stable and safe from falling over or falling down before operating.
• Do not sit or stand on the unit or use as a step.
• Do not leave device plugged in when not in use.
• Indoor use only. Do not expose to water or rain (store indoors.)
• Use only as described in this manual.
1.800.533.7533
USEPHOENIX.COM
2
• Use only Manufacturer’s recommended attachments. Contact Therma-Stor for proper repair instructions.
• Do not pull or carry it by the power cord, use cord as a handle, close doors on cord or pull cord around sharp edges.
• Do not run or drive over cord.
• Keep cord away from heated surfaces.
• Do not handle power cord plug with wet hands.
• Turn off all controls before unplugging.
• Do not use when you are tired, distracted or under the influence of drugs, alcohol or medication.
LIRE ET CONSERVER CES INSTRUCTIONS
• Risque de choc électrique Peut causer des blessures ou la mort. Débrancher toutes les alimentations en courant électrique à distance avant l’entretien ou le nettoyage.
• Ne pas utiliser l’appareil avec un cordon d’alimentation coupé ou effiloché.
• Ne pas débrancher l’appareil en tirant sur le cordon. Tenir la fiche fermement et la tirer hors de la prise murale ou la prise d’alimentation électrique.
• Toujours utiliser une prise mise à la terre.
• Ne jamais utiliser l’équipement électrique dans de l’eau stagnante.
• Ne jamais utiliser sans les grilles de protection. Des blessures risquent d’en résulter.
• Ne pas brancher plus de 8 ampères au total au différentiel.
• Vérifier la protection du différentiel avant chaque utilisation en appuyant sur le bouton “ test “. Si l’appareil fonctionne correctement, le bouton “ reset “ ressort.
• Ne pas passer les doigts ou d’autres objets dans les grilles de protection.
• Ne pas diminuer le débit d’air arrivant jusqu’à l’appareil. L’appareil risque de trop chauffer.
• Ne pas s’asseoir ou se tenir debout sur l’appareil; ne pas l’utiliser comme étagère ou table.
• Avant de laisser un appareil aéraulique axial sans surveillance, s’assurer que les enfants n’ont pas accès à l’équipement. Ne pas laisser les enfants jouer avec l’appareil ou à proximité de l’appareil ou dans l’air qu’il projette.
• Pour réduire le risque d’incendie ou de choc électrique, ne pas utiliser ce ventilateur avec un dispositif de commande de vitesse à semi-conducteurs.
2 Specifications
Part No.
Power 115 VAC, 60 hz.
Operating 3 – 0°, 45°, 90° Positions
Drive Motor 1 /3 Horsepower, 2-Speed
Motor Thermal cut-off
Protection Cord Length 20 Feet
Airflow 2800 ft/min outlet velocity
Current Draw 2.6 Amps High speed, 2.0 Amps Low speed
Warranty One Year - 100% parts and labor (all components)
Three Years - Only materials and workmanship of the housing are covered.
Dimensions Machine Shipping
Width 17.25” 17.3” Height 20” 20” Depth 19.4” 20” Weight 27 lb 30 lb
4030990
3 Power Requirements
3.1 Daisy Chaining
The Phoenix Centrifugal Air Mover draws 2.6 amps. The 12 amp, on-board circuit breaker will allow four (4) Phoenix Centrifugal Air Movers on one circuit. When daisy-chaining the Phoenix Centrifugal Air Mover, turn on one Phoenix Centrifugal Air Mover at a time to prevent excessive current inrush caused by four units starting at once.
A ground fault in the Phoenix Centrifugal Air Mover Pro or anywhere on the circuit will cause the Phoenix Centrifugal Air Mover’s GFCI to trip. After rectifying the ground fault, reset the GFCI by pressing the reset button.
5
1.800.533.7533
Figure 1: Too many Centrifugal Air Movers daisy-chained
USEPHOENIX.COM
3
Loading...
+ 4 hidden pages