Power / data supply for indoor and outdoor applications
PDS-60ca
Power / data supply for indoor and outdoor applications
PDS-60ca is a versatile power / data supply designed for indoor and outdoor LED lighting fixtures
low voltage fixtures from Philips Color Kinetics
• PDS-60ca is available in 7.5 V and 24 V
.
Compatible Fixtures
versions to meet the power requirements
of a variety of fixtures. Both 7.5 V and 24
V versions communicate control data via
Ethernet and DMX networks, allowing for
compatibility with the full range of Philips
Color Kinetics and third-party controllers.
• Features a NEMA 4 (IP66) enclosure, PDS60ca installs in dry, damp, and wet locations.
• Accommodates input voltages ranging
from 100 VAC to 240 VAC. Short circuit
protection
prevents device failure due to
DeviceFixture
PDS-60ca 7.5 ViColor Flex MX120 nodes
Flex
Micro 120 nodes
eW
eW Flex Compact60 nodes
iColor Flex LMX60 nodes
PDS-60ca 24 V
iColor Cove EC 7 in30 xtures
iColor Cove EC 12 in30 xtures
iColor Cove QLX 6 in30 xtures
iColor Cove QLX 12 in20 xtures
Max. Quantity
Per Device
incorrectly wired fixtures.
•
PDS-60ca is available in a pre-programmed
version, which features built-in visual effects
and allows for light show configuration
without controllers.
• Offers multiple standard-size conduit entries
to
accommodate 1/2 in and 3/4 in
US trade-
sized conduit.
• PDS-60ca Pre-Programmed functions as a
master controller, delivering data to the other
power / data supplies in the run. Use one
Versions and Features
VersionFeatures
PDS-60ca 7.5 V
DMX / Ethernet
PDS-60ca 24 V
DMX / Ethernet
PDS-60ca 7.5 V
Pre-Programmed
PDS-60ca 24 V
Pre-Programmed
Compatible with both DMX and Ethernet
networks. On-board indicators show the
status of the data connection.
Has congurable, on-board effects. Cannot
receive controller data, but can send data
to downstream power / data supplies and
connected xtures.
PDS-60ca Pre-Programmed unit per run, and
standard additional power / data supplies. A
downstream power / data supply does not
have to be a PDS-60ca, but can be any DMXor Ethernet-based power / data supply.
• Instead of attaching fixtures to a PreProgrammed PDS-60ca, you could use it as an
outdoor-rated light show controller for DMXor Ethernet-based power / data supplies and
their fixtures.
employing
Versatile power / data
supply for indoor and
outdoor applications
The device’s NEMA 4 (IP66)
enclosure allows for installation in
dry, damp, and wet locations.
PDS-60ca Product Guide2
Specications
Due to continuous improvements and innovations, specifications may change without notice.
Maximum Input Current 1.7 A at 100 VAC, 1.5 A at 120 VAC, .75 A at 240 VAC
Electrical
Power Output
Fuse Rating
Dimensions
(Height x Width x Depth)
Weight4.5 lb (2.0 kg)
Construction
Connectors
Temperature Ranges
Physical
Humidity0 – 95%, non-condensing
CoolingConvection
Heat Dissipation25% of total power input at maximum load
Data Input Source
CerticationUL / cUL, CE, PSE
Certication
and Safety
ClassicationUL Class 2 power supply
EnvironmentDry / Damp / Wet Location, IP66
KiNET
is the Ethernet lighting protocol from Philips Color Kinetics.
*
PDS-60ca 7.5 V 7.5 VDC, 60 W maximum
PDS-60ca 24 V24 VDC, 60 W maximum
PDS-60ca 7.5 V (2) 5 A, 5 x 20 slow blow fuses
PDS-60ca 24 V(2) 4 A, 5 x 20 slow blow fuses
3.6 x 5.5 x 8.8 in (91 x 140 x 224 mm)
Cast aluminum enclosure with gray powder-coated
nish
DataRJ45 input and output connectors
ower Output
P
(2) 4-pin output receptacles
Power InputLine-neutral-ground cable, ying leads
14° – 104° F (-10° – 40° C) Operating
14° – 122° F (-10° – 50° C) Startup
-40° – 176° F (-40° – 80° C) Storage
PDS-60ca 7.5 V
DMX / Ethernet
PDS-60ca 24 V
DMX / Ethernet
Philips full range of controllers,
third-party DMX controllers, or
KiNET-compatible* third-party
Ethernet controllers
PDS-60ca 7.5 V
Pre-Programmed
PDS-60ca 24 V
Internal
Pre-Programmed
2 in
(51 mm)
5.5 in
(140 mm)
3.6 in
(91 mm)
8.3 in
(211 mm)
8.8 in
(224 mm)
(224 mm)
8.8 in
OUT 1OUT 2
ETHERNET
Sized for 1/2 in US
Sized for 1/2 in (13 mm)
trade-size conduit
trade-size conduit
Sized for 3/4 in US
Sized for 3/4 in (19 mm)
trade-size conduit
trade size conduit
DMX IN
OUT 1OUT 2
ETHERNET
DMX OUT
DMX IN
DMX OUT
Mounting
Slots
1 in
(25 mm)
.8 in
(20 mm)
Ordering Information
ItemItem NumberPhilips 12NC
PDS-60ca 7.5 V DMX / Ethernet 109-000015-03910503700094
PDS-60ca 7.5 V Pre-Programmed109-000015-00910503700093
PDS-60ca 24 V DMX / Ethernet109-000016-04912400133526
PDS-60ca 24 V Pre-Programmed109-000016-00910503700095
Use Item Number when ordering in North America.
5.5 in
(140 mm)
Included in the box
PDS-60ca power / data supply
(2) White clamp-on EMI suppression cores
Black clamp-on EMI suppression core
(2) Spare fuses
(4) Sealing plugs and rings 1/2 NPT
(4) Sealing plugs and rings 3/4 NPT
DMX/ETHERNET
OUT 1
IN
OUT 2
DMX
OUT
PDS-60ca Product Guide3
Installation
Power /
Data Suppl
y
Controller
328 ft (100 m) Max
Ethernet
Switch
Light
System
Manager
PC
PDS-60ca 24 V
DMX/Ethernet
Flex MX
PDS-60ca is a power / data supply designed
lighting installations.
PDS-60ca
provides power and data to up to 30 low-voltage fixtures
from Philips Color Kinetics and delivers 60 watts of low-voltage output via two ports. It
features a NEMA 4 (IP66) enclosure, and can be installed in dry, damp, and wet locations.
It automatically accommodates input voltages ranging from 100 VAC to 240 VAC.
for low-voltage linear DMX and Ethernet
Owner / User Responsibilities
It is the responsibility of the contractor, installer, purchaser, owner, and user to install,
maintain, and operate
PDS-60ca
in such a manner as to comply with all applicable codes,
state and local laws, ordinances, and regulations. Consult with the appropriate electrical
inspector to ensure compliance.
Plan the Installation
To streamline installation and ensure accurate conguration, start with a layout or a
lighting design plan that shows the physical layout of the installation and identies the
locations of all lighting xtures,
DMX, Ethernet, and Pre-Programmed Congurations
PDS-60ca DMX / Ethernet
Programmed versions cannot receive controller data, but can send light show data to
DMX or Ethernet power / data supplies using the pre-programmed device’s OUT port.
DMX is appropriate for relatively simple installations, or for installations in which
groups of lights operate in unison (for example, for accent lighting, perimeter lighting,
or cove lighting applications). Typical DMX installations with fixtures from Philips
Color Kinetics use a controller such as iPlayer 3, a Controller Keypad for turning lights
on and off and triggering light shows, and one or more PDS-60ca devices. PDS-60ca
devices can be connected in series to deliver DMX data from a single controller to all
connected lights. Note that the maximum for DMX data run lengths is 1000 ft (305 m).
Because it is not subject to the DMX addressing limitations, Ethernet is the preferred
environment for large-scale, color-changing light shows and video displays, both of
which require large numbers of unique addresses.
power / data supplie
s, controllers, switches, and cables.
can be used in either DMX or Ethernet networks. Pre-
E Refer to the PDS-60ca Installation
Instructions for specic warning and caution
statements.
Pre-Programmed Installation
Power /
Controller
Data Supply
Flex MX
iPlayer 3
Controller
PDS-60ca 24V
DMX/Ethernet
Typical Ethernet installations with LED lighting fixtures from Philips Color Kinetics use an
Ethernet switch, an Ethernet controller (such as Light System Manager, ColorDial Pro or
Video System Manager Pro), one or more Ethernet Controller Keypads (for light show
triggering), and one or more PDS-60ca devices. For additional devices in a network, use
additional Ethernet switch ports.
In an Ethernet environment, each Philips Color Kinetics power / data supply has a
unique IP address. Each fixture connected to the device is automatically assigned
unique identifiers that controllers use to identify and manage each fixture.
Maximum data cable lengths are 328 ft (100 m) between Ethernet devices without a
re p e ater.
PDS-60ca Product Guide4
1000 ft (305 m) Max
DMX maximum data run length
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.