Philips T8 PLUS, T8 32W, 36W PL-C3, T8 XLL, 32W PL-T User Manual

...
Healthcare Lighting Energy Saving Upgrade Guide
Sustainable solutions help create a positive atmosphere and control operational costs
Retrofit Solutions—Upgrade your system by simply upgrading the lamps
PHILIPS ENERGY SAVING
UPGRADE PRODUCT
Standard 32W 4ft T8
Standard 32W 4ft T8
Standard 32W T8 U-Bent
Standard 40W PL-L
Standard 32W PL-T
Standard 26W PL-C
§ Rated average life is the length of operation (in hours) at which point an average of 50% of a large sample of lamps will still be operational and 50% will not. † Based on (wattage saved) multiplied by (upgrade product rated average life) divided by (1000 x kWh rate (.10)) = Amount saved in dollars. †† Current lamp watts - Upgrade watts.
1. On Instant Star t ballast, a standard 40W PL-L only draws 32W,so the actual savings is 7W (32W-25W=7W).This is an ener gy savings of 18% over the standard 40W PL-L (7W/40W=18%).
2.The actual savings when switching from a standard 32W PL-T to a Philips Ener gy Advantage 27W PL-T is 5W (32W-27W=5W and 5W/32W=15.6%).
3.The actual savings when switching from a standard 26W PL-C to a Philips Ener gy Advantage 21W PL-C is 5W (26W-21W=5W and 5W/26W=19%).
Philips Energy Advantage T8 XLL 25W 4ft featuring ALTO II™Technology
Philips Energy Advantage T8 25W 4ft featuring ALTO II
Philips Energy Advantage T8 U-Bent 25W featuringALTO
Philips Energy Advantage PL-L 25W featuringALTO
Philips Energy Advantage PL-T 27W featuringALTO
Philips Energy Advantage PL-C 21W featuringALTO®Lamp Technology
Technology
®
Lamp Technology
®
Lamp Technology
®
Lamp Technology
RATED
AVERAGE
LIFE
40,000 hrs.
@ 12 hr.
Instant Start
30,000 hrs.
@ 12 hr.
Instant Start
24,000 hrs.
@ 12 hr.
Instant Start
24,000 hrs.
@ 12 hr. Start
20,000 hrs.
@ 12 hr. Start
16,000 hrs.
@ 12 hr. Start
§
ENERGY SAVINGS
(PER LAMP)
$28.00
$21.00
$16.80
$16.80
$10.00
$8.00
WATTS
SAVED
(PER LAMP)
7W
7W
7W
7W
5W
5W
††,1
††,2
††,3
See reverse side for System Upgrade Solutions.
††
††
††
ADDED BENEFITS
BENEFIT OF UPGRADINGCURRENT LAMP
• Only 1.7 mg of mercury • 48 month warranty period
• 97% lumen maintenance
• Fully dimmable without burn-in
• Only 1.7 mg of mercury • 36 month warranty period
• 97% lumen maintenance
• Fully dimmable without burn-in
• Sustainable lighting solution—reduces the impact on the environment with only 3 mg of mercury per lamp
• 36 month warranty period
• 18% Energy Savings vs. the Standard 40W PL-L
• Only 1.4 mg of mercury • 95% lumen maintenance
• 88% lumen maintenance
• 15.6% Energy Savings vs. the Standard 32W PL-T
• Only 1.4 mg of mercury
• 88% lumen maintenance
• 19% Energy Savings vs. the Standard 36W PL-C
• Only 1.4 mg of mercury
1
2
3
DESIRED
BENEFITS KEY
Energy savings Long life Quality of light Low Mercury
Reduced Maintenance Costs
Healthcare Lighting Energy Saving Upgrade Guide
System Upgrade Solutions—Replace lamps and ballasts to meet lighting requirements
CURRENT
LAMP
Standard 34W 4ft T12 Electromagnetic Ballast
Standard 34W 4ft T12 Electromagnetic Ballast
Standard 34W 4ft T12 Electromagnetic Ballast
§ Rated average life is the length of operation (in hours) at which point an average of 50% of a large sample of lamps will still be operational and 50% will not. † Two lamp system. Based on (wattage saved) multiplied by (upgrade product r ated average life) divided by (1000 x kWh rate (.10)) = Amount saved in dollar s. †† Current lamp watts - Upgrade watts. Based on a two lamp system.
CURRENT
BALLAST
PHILIPS ENERGY SAVING
UPGRADE PRODUCT
Philips Energy Advantage T8 XLL 25W 4ft featuring ALTO II™Technology
Philips T8 PLUS 32W 4ft featuring ALTO II Technology
Philips 800 Series T8 32W 4ft featuring ALTO II™Technology
RATED
AVERAGE
LIFE
40,000 hrs.
@ 12 hr.
Instant Start
36,000 hrs.
@ 12 hr.
Instant Start
30,000 hrs.
@ 12 hr.
Instant Start
PHILIPS ADVANCE
§
ELECTRONIC
BALLAST UPGRADE
Optanium Efficiency Ballast IOP-2P32-LW-SC
Optanium Efficiency Ballast IOP-2P32-LW-SC
Optanium Efficiency Ballast IOP-2P32-LW-SC
See reverse side for Retrofit Solutions.
DESIRED
BENEFITS KEY
Energy savings Long life Quality of light Low Mercury
®
High
®
High
®
High
Reduced Maintenance Costs
ENERGY SAVINGS
$136
$86†24
$72†24
SYSTEM
WATTS
SAVED
34
W
W
W
††
††
††
ADDED BENEFITS
BENEFIT OF UPGRADING
• Only 1.7 mg of mercury
• Longest life for increased savings on maintenance and recycling costs
• 36 month warranty period
• 95% lumen maintenance
• Only 1.7 mg of mercury
• 30 month warranty period
• 95% lumen maintenance
• Only 1.7 mg of mercury
• 82 CRI—Excellent color rendering
© 2009 Philips Lighting Company. All rights reserved. Printed in USA 2/09 P-5989 www.philips.com Philips Lighting Company
200 Franklin Square Drive P.O.Box 6800 Somerset, NJ 08875-6800 1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050
A Division of Philips Electronics Ltd.
10275 West Higgins Road Rosemont, IL 60018-5603 1-800-322-2086
A Division of Philips Electronics North America Corporation
www.philips.com/advance
Loading...