Lighting Controls
SpaceWise
Quick start
guide
Wireless lighting control solutions from Philips
for oce and industrial applications

70% G
min
100 h
group
link? mode?
mode
power upbackground IR group reset
add
pirdelay daylight RF channel
0
0
o
save
on
I/ II
O
)))
A-G
zone
%
on/o
87 9
50% E40% D 60% F
54 6
20% B10% A
II
30% C
PLBMS W/C
21 3
test
cong
scene
group
mode
cong
daylight
reset
0
save
SpaceWise remote
On
Open
Send
Unlock
II
70% G
on
cong
link? mode?
PLBMS W/C
21 3
20% B10% A
50% E40% D 60% F
min
30% C
54 6
87 9
0
save
)))
O
test
add
zone
I/ II
o
group
mode
100 h
O
Test
Close
Mode
Add
Zone
PIR
2 Philips Lighting Controls
on/o
power upbackground IR group reset
scene
A-G
%
pirdelay daylight RF channel
0
Lock
Reset
Daylight

Table of
contents
pg.
4
Oce applications
pg.
18
pg.
30
pg.
31
Industrial applications
Troubleshooting
Frequently asked questions
3

4 Philips Lighting Controls
Getting Started: Oce
Installation and conguration of luminaires with
SpaceWise technology
Fixtures must be installed by a qualied electrician in accordance with all national
and local electrical and construction codes and regulations.
1.
• Luminaire installation instructions
(In luminaire box)
• Accessory installation (In accessory box)
• SpaceWise User Manual
• SpaceWise Design Guide
Conrm all components received
Luminaires SpaceWise
remote
Optional wireless wall switch, scene selector and external ceiling sensors.
Instructions:
Additional information can be found at www.philips.com/spacewise:

5
2.
3.
Determine luminaire orientation
Plan luminaire wireless groups
Ensure sensor is facing away
from window.
Ensure sensors from
adjacent luminaires are
not positioned next to
one another.
Install luminaires per manufacturer installation instructions.
When conguring open plan oces with the SpaceWise Remote,
large groups of 30-50 luminaires are recommended to maintain
the lighting aesthetics of the space. Smaller groups may turn o
more frequently than desired.
Group 1
Group 1 Group 2

6 Philips Lighting Controls
4.
Create a group
Grouping is required to initiate system functionality and dimming behaviors.
4b.
Add luminaires to group
Walk to the next
luminaire to be
added to the
group, point to
the luminaire
and press “add.”
Repeat step for adding all the luminaires in the group.
Luminaire
Luminaire
4a.
Open Group
Luminaire
Luminaire
Point remote to
any luminaire
and press
“open,” once.
Luminaire
Luminaire
Wait for the luminaire to
dim down to 5%.
Luminaire will dim
down to 5%.
Make sure the button is pressed only once. Pushing multiple times
can create multiple networks which can cause undesired operation.
The Luminaire/s have to be in a factory new state to group them
together. If changes were previously made on the luminaires
then perform a factory reset as per the troubleshooting instructions
on page 30 of this manual.
All actions are to be performed by standing underneath a luminaire
and pointing the remote directly towards the luminaire sensor.

7
Luminaire
Luminaire
4e.
Lock the group
The luminaire will
FLASH twice and
group will turn OFF
and ON once for
daylight calibration.
Group is ready for
normal operation.
Point to any of
the luminaires
in the group
and press “lock.”
Wait for LED to
stop blink ing
(apx. 10 seconds)
then press “send.”
Luminaire
Luminaire
4d.
Verify the group
Point to any of the
luminaires in the
group and press
“o” and “on.”
All the luminaires in the
group will turn
OFF and ON together.
If any luminaires in the group do not turn ON/OFF, they are not
part of the group. Go back to step 4a to add the luminaires back
in to the group.
4c.
Close group
Luminaire
Luminaire
Point to any of
the luminaires
added in the
group and
press “close.”
All the luminaires in the
group will go to 50%
light level.
Red LED on
remote will
start blinking.
Luminaire
Luminaire
Luminaire

8 Philips Lighting Controls
5.
Choose an application mode
Application ON/OFF behavior Mode
Hold
time
1
Prolong
time
2
Open Oce Auto ON/Auto OFF 24 10 min 15 min
Open Oce Manual ON/Auto OFF 25 10 min 0 min
Private Oce/
Meeting room
Auto ON/Auto OFF 1 10 min 15 min
Private Oce/
Meeting room
Manual ON/Auto OFF 3 10 min 0 min
Corridors and
Stairwells
Auto ON/Auto OFF 26 5 min 15 min
Corridors and
Stairwells
Auto ON/No auto OFF 5 5 min Innite
1. Hold tim e is the occupancy t ime out after wh ich the luminai re dims from the task l evel to the backgrou nd level.
2. Prolong t ime is the time fo r which the lumina ire stays at the bac kground level bef ore switching o.
Choose the desired application mode per group. Behavior varies for each
application. See the SpaceWise Design Guide for more details.
Luminaire
Luminaire
5a.
Unlock the group
The luminaire will
FLASH twice and
group light level
will go to 50%.
Point to any of
the luminaires
in the group and
press “unlock.”
Wait for LED to
stop blink ing
(apx. 10 seconds)
then press
“send.”
Red LED on
remote will
start blinking.
Red LED on
remote will
stop blinking.
Luminaire

9
5b.
Set application mode
Lock the group,refer to
step 4e.
• After locking light ing
group is operational in
selected mode.
Luminaire
Luminaire
The luminaire will
FLASH twice and
group light level will
go to 50%.
Point to any of
the luminaires
in the group and
press “mode.”
While the LED is still
blinking red, enter the
number for the preferred
mode (see list at step 5).
Point to any of
the luminaires
in the group,
press “send.”
6.
Change maximum light output
Light output setting Max light output options
High 100%
Medium (Default) 88%
Low 77%
Minimum 66%
Choice of max light output per group will be inuenced by existing
conditions such as partition height, reectances, light level preference and
energy goals.
Red LED on
remote will
start blinking.
If unsure about mode selection or remote blinking status then wait
for the remote blinking to stop and redo step 5b.
Luminaire

6a.
group
mode
cong
daylight
reset
0
save
100 h
mode
add
pirdelay daylight RF channel
0
O
)))
A-G
zone
%
test
save
min
group
mode
0
o
save
I/II
O
)))
87 9
50% E40% D 60% F
54 6
20% B10% A
30% C
PLBMS W/C
21 3
group
mode
cong
daylight
reset
0
Set light output per group
Unlock the group, refer to step 5a.
• Group will be unlocked for further operation.
Luminaire
Luminaire
To select light output settings, use the up and down
arrows to change between high, medium, low and
minimum. Light level can be altered one step at a time.
The daylight button must be pressed to initiate a new
change after every end of step.
For each step up or down:
10 Philips Lighting Controls
Point to any luminaire
in the group and
press “daylight.”
While the remote is
blinking, select:
or
Then press “send.”
End of step.
Lock the group, refer to step 4e.
• After locking, lighting group is operational at selected light level.
Note that the default set ting is Medium. To get to high, go one step up.
To get to Minimum, go two steps down.
Medium
to High
Medium
to Low
Low to
Minimum
If unsure about light output selection, step up to the highest setting
and observe the subtle reduction in light level each time you
activate lower settings.
Will move light output setting from default
of 88% to 100%.
Will move light output setting from default
of 88% to 77%.
Will move light output setting from default
of 77% to 66%.
Red LED on
remote will
start blinking.
Red LED on
remote will
stop blinking.
Depending on the
sensor rmware
version, lights may or
may not ash twice
to conrm the light
level change.

11
Luminaire
Luminaire
7a.
Unlock the group
The luminaire will
FLASH twice and
group light level
will go to 50%.
Point to any of
the luminaires
in the group and
press “unlock.”
Wait for LED to
stop blink ing
(apx. 10 seconds)
then press
“send.”
Red LED on
remote will
start blinking.
Red LED on
remote will
stop blinking.
Luminaire
7.
Link a wireless switch to a group
Up to 5 switches and scene selectors can be linked together in a group.
The switch uses EnOcean technology and does not need bat teries or any
power supply. Every time the switch is physically pressed it generates
energy and transmits a wireless message to the luminaires.
• A small press and release action on the rocker will turn
on or turn o the lights.
• A long press and hold action on the rocker w ill dim the
lights accordingly.
7b.
Open Group
Luminaire
Luminaire
Point remote to
any luminaire
and press
“open,” once.
Luminaire
Wait for the entire
luminaire group to
dim down to 5%..
Make sure the button is pressed only once. Pushing multiple times
can create multiple networks which can cause undesired operation.

12 Philips Lighting Controls
7c.
7d.
7e.
Rocker switch
Link the switch
Program the switch
Remove the rocker pad cover of the switch by applying pressure at the
back of the switch. You will nd 4 small buttons behind the rocker pad.
Step 7d is a trial and error process. The 4 buttons signify 4 dierent
wireless channels. To join the switch to the luminaire group the
wireless channel of the switch and the luminaire must match. Since
the wireless channel of the luminaire is not visible, one has to try out
all the 4 channels via the buttons to determine the matching channel
as described in step 7e.
Model: UID
84x
1/1
0
9137
003
64
x03
2
1
10 sec.
+
2
1
1
+
2
10 sec.
2
1
+
+
2
1
10 sec.
or or
10 sec.+
2
1
If the switch joins
the group then the
luminaire will FLASH
twice and group light
level will go to 5%.
If the switch joins
the group then the
luminaire will FLASH
twice and group light
level will go to 5%.
Select the correct wireless channel by
pressing and holding one of the small
buttons (1) and horizontal bar (2) for at
least 10 seconds.
If the switch did not join the group as
per step d then repeat step d but with
a dierent button (1) this time.
Luminaire
Luminaire

13
7f.
Close group
Luminaire
Luminaire
Point to any of
the luminaires
added in the
group and
press “close.”
All the luminaires in the
group will go to 50%
light level.
Luminaire
7g.
Test the switch
click
click
= energy
All the luminaires in
the group will turn on/
o based on the rocker
pad action.
Install the rocker pad back on the
switch and test the switch by pressing
the rocker pads.
Luminaire
Luminaire
Luminaire
7h.
Lock the group
The luminaire will
FLASH twice and
group will turn OFF
and ON once for
daylight calibration.
Group is ready for
normal operation.
Point to any of
the luminaires
in the group
and press “lock.”
Wait for LED to
stop blink ing
(apx. 10 seconds)
then press “send.”
Red LED on
remote will
start blinking.
Luminaire

14 Philips Lighting Controls
A maximum of 5 user interfaces, any combination of switches and/or
scene selectors can be linked together in a group. The factory default
reactions for each button are:
• “I” Activates the automatic behavior
where the light levels are set by
the sensor.
• “O” Turns o the lights.
• “•” Recalls scene 2 (default 20%) and
overrides the light levels set by
the sensor.
• “• •” Recalls scene 3 (default 40%) and
overrides the light levels set by
the sensor.
8.
Link a wireless scene selector to a group
The scene selector can only recall a light level stored as a scene and
does not act as a dimmer. For dimming functionality use the wireless
switch. A long press action on the scene selector button will delink
the scene selector from the SpaceWise group.
Luminaire
Luminaire
8a.
Unlock the group
The luminaire will
FLASH twice and
group light level
will go to 50%.
Point to any of
the luminaires
in the group and
press “unlock.”
Wait for LED to
stop blink ing
(apx. 10 seconds)
then press
“send.”
Red LED on
remote will
start blinking.
Red LED on
remote will
stop blinking.
Luminaire

15
8b.
Open Group
Luminaire
Luminaire
Point remote to
any luminaire
and press
“open,” once.
Luminaire
Wait for the the entire
luminaire group to dim
down to 5%.
Make sure the button is pressed only once. Pushing multiple times
can create multiple networks which can cause undesired operation.
8c.
Link the scene selector
Step 8c is a trial and error process. The 4 buttons signify 4 dierent
wireless channels. To join the scene selector to the luminaire group
the wireless channel of the scene selector and the luminaire must
match. Since the wireless channel of the luminaire is not visible, one
has to try out all the 4 channels via the buttons to determine the
matching channel as described in step 8d.
10 sec.
If the switch joins
the group then the
luminaire will FLASH
twice and group light
level will go to 5%.
Select the correct wireless channel
by pressing and holding one of the
4 buttons for at least 10 seconds and
then release the button.
Luminaire
8d.
Program the scene selector
10 sec.
10 sec.
10 sec.
If the switch joins
the group then the
luminaire will FLASH
twice and group light
level will go to 5%.
If the switch did not join the group as
per step d then repeat step d but with
a dierent button (1) this time.
Luminaire

16 Philips Lighting Controls
8g.
Scene selector
Test
All the luminaires in
the group will react to
the button action.
Test the scene selector by pressing
the buttons.
Luminaire
8e.
Close group
Luminaire
Luminaire
Point to any of
the luminaires
added in the
group and
press “close.”
All the luminaires in the
group will go to 50%
light level.
Luminaire
Luminaire
Luminaire
8f.
Lock the group
The luminaire will
FLASH twice and
group will turn OFF
and ON once for
daylight calibration.
Group is ready for
normal operation.
Point to any of
the luminaires
in the group
and press “lock.”
Wait for LED to
stop blink ing
(apx. 10 seconds)
then press “send.”
Red LED on
remote will
start blinking.
Luminaire

18 Philips Lighting Controls
Getting Started: Industrial
Installation and conguration of luminaires with
SpaceWise technology
Fixtures must be installed by a qualied electrician in accordance with all national
and local electrical and construction codes and regulations.
1.
• Luminaire installation instructions
(In luminaire box)
• Accessory installation (In accessory box)
• SpaceWise User Manual
• SpaceWise Design Guide
Conrm all components received
Luminaires SpaceWise
remote
Instructions:
Additional information can be found at www.philips.com/spacewise:

19
2.
3.
Determine luminaire orientation
Plan luminaire wireless groups
Install luminaires per manufacturer installation instructions.
Do not install the luminaire
close to steel or concrete
constructions and maintain
a safe distance between air
outlets and the luminaire.
Orient the rst luminaire in the isle in the right
position with respect to the edge of the isle.
When conguring open plan areas with the SpaceWise Remote, large groups
of 30-50 luminaires are recommended to maintain the lighting aesthetics of
the space. Smaller groups may turn o more frequently than desired.
Group 1
Group 1 Group 2
2 ft.
2 m
6½ ft.
h
min: ½ h
max: ½ h + 6½ ft.

20 Philips Lighting Controls
4.
Create a group
Grouping is required to initiate system functionality and dimming behaviors.
4b.
Add luminaires to group
Walk to the next
luminaire to be
added to the
group, point to
the luminaire
and press “add.”
Repeat step for adding all the luminaires in the group.
Luminaire
Luminaire
4a.
Open Group
Luminaire
Luminaire
Point remote to
any luminaire
and press
“Open,” once.
Luminaire
Luminaire
Wait for the luminaire to
dim down to 5%.
Luminaire will dim
down to 5%.
Make sure the button is pressed only once. Pushing multiple times
can create multiple networks which can cause undesired operation.
The Luminaire/s have to be in a factory new state to group them
together. If changes were previously made on the luminaires,
then perform a factory reset as per the troubleshooting instructions
on page 30 of this manual.
All actions are to be performed by standing underneath a luminaire
and pointing the remote directly towards the luminaire sensor.

21
Luminaire
Luminaire
4e.
Lock the group
The luminaire will FL ASH
twice. Group is ready for
normal operation.
Point to any of
the luminaires
in the group
and press “lock.”
Wait for LED to
stop blink ing
(apx. 10 seconds)
then press “send.”
Luminaire
Luminaire
4d.
Verify the group
Point to any of the
luminaires in the
group and press
“o” and “on.”
All the luminaires in the
group will turn
OFF and ON together.
If any luminaires in the group do not turn ON/OFF, they are not
part of the group. Go back to step 4a to add the luminaires back
in to the group.
4c.
Close group
Luminaire
Luminaire
Point to any of
the luminaires
added in the
group and
press “close.”
All the luminaires in the
group will go to 50%
light level.
Red LED on
remote will
start blinking.
Luminaire
Luminaire
Luminaire

22 Philips Lighting Controls
5.
Choose an application mode
Choose the desired application mode per group. Behavior varies for each
application. See the SpaceWise Design Guide for more details.
Luminaire
Luminaire
5a.
Unlock the group
The luminaire will
FLASH twice and
group light level
will go to 50%.
Point to any of
the luminaires
in the group and
press “unlock.”
Wait for LED to
stop blink ing
(apx. 10 seconds)
then press
“send.”
Red LED on
remote will
start blinking.
Red LED on
remote will
stop blinking.
Luminaire
Application ON/OFF behavior Mode
Hold
time
1
Prolong
time
2
Warehouse Auto ON/Auto OFF 6 2 min 2 min
Gymna sium Auto ON/Auto OFF 7 5 min 5 min
Warehouse
Comfor t
Auto ON/Auto DIM to
Background Level
8 2 min Innite
Manufacturing
Auto ON/Auto DIM to
Background Level
9 5 min Innite
1. Hold tim e is the occupancy t ime out after wh ich the luminai re dims from the task l evel to the backgrou nd level.
2. Prolong t ime is the time fo r which the lumina ire stays at the bac kground level bef ore switching o.

23
5b.
Set application mode
Lock the group,refer to
step 4e.
• After locking light ing
group is operational in
selected mode.
Luminaire
Luminaire
The luminaire will
FLASH twice and
group light level will
go to 50%.
Point to any of
the luminaires
in the group and
press “mode.”
While the LED is still
blinking red, enter the
number for the preferred
mode (see list at step 5).
Point to any of
the luminaires
in the group,
press “send.”
6.
Creating zones in a group
Red LED on
remote will
start blinking.
If unsure about mode selection or remote blinking status then wait
for the remote blinking to stop and redo step 5b.
Luminaire
Up to 16 zones can be created within a SpaceWise group and each luminaire
can be part of just one zone.
All luminaires within the zone will react the same way to any sensor in the
zone. That is, all luminaires in the zone will simultaneously increase light
level upon motion detection or will simultaneously dim down to background
level when there is no motion.
123 5
4
Group
Zone
Zones can only be created within a group. A group needs be created
rst as per the instructions in section 4.

24 Philips Lighting Controls
Luminaire
Luminaire
6a.
Unlock the group
The luminaire will
FLASH twice and
group light level
will go to 50%.
The luminaire will go to
50% while the rest of
the luminaires go to 5%.
Point to any of
the luminaires
in the group and
press “unlock.”
Wait for LED to
stop blink ing
(apx. 10 seconds)
then press
“send.”
Red LED on
remote will
start blinking.
Red LED on
remote will
stop blinking.
Luminaire
Luminaire Group
6b.
Set zone
Luminaire
Luminaire
Point to any of
the luminaires
that is going to
be part of the
zone and press
“Zone,” once.
Make sure the zone button is pressed only once. Up to 16 zones
can be dened and every time the zone button is pressed a new
zone creation process is initiated.

25
Added luminaire will
go to 50%.
Luminaire
6c.
Build zone
Luminaire
Luminaire
Walk to the next
luminaire to be
added to the
zone, point to
the luminaire
and press “add.”
To create new zones repeat steps 6b and 6c. Note that a luminaire
can only be part of one zone.
Repeat step for adding all the luminaires in the zone.
Press the right arrow key again to move to verify the next zone.
6d.
Close zone
Luminaire
Luminaire
Point to any of
the luminaires
added in the
zone and
press “close.”
All the luminaires in the
group will go to 50%
light level.
Luminaire
All the luminaires in
the selected zone will
go to 50% while the
luminaires in other
zone/s will go to 5%.
Luminaire Group
6e.
Test zone
Luminaire
Luminaire
Point to any of
the luminaires
in the zone and
press the
“right arrow”

26 Philips Lighting Controls
Luminaire
Luminaire
6f.
Lock the zone
The luminaire will FL ASH
twice. Group is ready for
normal operation.
Point to any of
the luminaires
in the zone
and press “lock.”
Wait for LED to
stop blink ing
(apx. 10 seconds)
then press “send.”
Red LED on
remote will
start blinking.
Luminaire
The entire zone turns
on or o accordingly.
Luminaire
Luminaire
6g.
Test zone while locked
Luminaire
Luminaire
Point to any of
the luminaires
in the zone and
press “zone”
Point to the same
luminaire in the
zone and press
“on” or “o.”
To stop the test
process, point
to the same
luminaire and
press “close.”

27
7.
Daylight Calibration
Daylight calibration should be performed during night time.
Daylight calibration is set for all the luminaires in the group.
Luminaire
Luminaire
Luminaire
Luminaire
7a.
7b.
Unlock the group
Calibrate the group
The luminaire will
FLASH twice and
group light level
will go to 50%.
Point to any of
the luminaires
in the group and
press “unlock.”
Point remote to any of the
luminaires and adjust the
group light level to the
required level using the
dimming “up” or “down”
arrow keys
Wait for LED to
stop blink ing
(apx. 10 seconds)
then press
“send.”
Red LED on
remote will
start blinking.
When the
arrow keys
are pressed,
red LED on
remote will
keep blinking.
The group
will dim up
or down
accordingly.
Red LED on
remote will
stop blinking.
Luminaire
or

28 Philips Lighting Controls
Luminaire
Luminaire
7c.
Save the calibration
Point to the same
luminaire in the group and
press the “save” button,
the light level is stored as
a new daylight set-point.
Red LED on
remote will
start blinking.
The luminaire will
FLASH twice and
group light level
will go to 50%.
Luminaire
Luminaire
Luminaire
7d.
Lock the new light level
The luminaire will
FLASH twice and the
group will adjust its light
level as per the new
daylight set point.
Point to any of
the luminaires
in the group
and press “lock.”
Wait for LED to
stop blink ing
(apx. 10 seconds)
then press “send.”
Red LED on
remote will
start blinking.
Luminaire

Troubleshooting
group
mode
daylight
reset
0
min
group
mode
0
o
save
I/II
O
)))
87 9
50% E40% D 60% F
54 6
20% B10% A
30% C
PLBMS W/C
21 3
group
mode
cong
daylight
reset
0
Luminaire
Luminaire
Luminaire
Luminaire
Luminaire
Luminaire
Factory reset will restore the luminaire to its default state and all
the group conguration settings will be deleted.
Reset operation can be used to bring any wrongly congured
luminaire back to its original factory reset condition.
Unlock the group, refer to step 5a
• Group will be unlocked for further operation.
Luminaire
Luminaire
Luminaire
Luminaire
Point to any of
the luminaires
in the group and
press “reset.”
Once the LED
stops blinking,
with remote sill
pointing to the
same luminaire,
press "send."
Repeat step for every luminaire that needs to be reset.
Red LED on
remote will
start blinking.
Luminaire will turn OFF
and then turn back ON
to indicate reset.
30 Philips Lighting Controls

Frequently asked
questions
My luminaire group is at low light level and does not respond to
SpaceWise remote buttons.
Luminaire may be in “open” group state. “close” the group
by referring to instructions in step 4c.
My luminaires are not turning o at night.
Ensure the luminaire group is in “locked” operational state.
Refer to instructions in step 4e to lock the luminaire group.
Some luminaires do not react with rest of the group
on/o command.
Luminaires are not properly grouped with the rest of group. Reset
the luminaire by following the instructions on page 30. Then
re-group the luminaire by referring to instructions in step 4.
My luminaires do not turn on.
If luminaires are in manual “on” mode, they may have been
turned “o” by accessory wall switch. Try turning “on” using
the switch.
Luminaires can also be accidentally turned o by remote
in “unlocked” state. Refer to instruction in step 4e to “lock”
the group.
Do my luminaires forget their settings after power is lost?
No, all settings are retained as long as the luminaires have not
been factory reset or there has been a hardware failure.
Technical Support
For technical support please contact 1-800-372-3331 and select
the controls prompt option.
31

© 2015 Koninklijke Philips N.V. All rights reserved. Philips reserves the right to
make changes in specications and/or to discontinue any product at any time
without notice or obligation and will not be liable for any consequences resulting
from the use of this publication.
PLt-15118QG 12/15 philips.co m/luminaires
Philips Lighting
North America Corporation
200 Franklin Square Drive
Somerset, NJ 08873
Tel . 8 55- 48 6-2 216
Philips Lighting Canada Ltd.
281 Hillmount Rd,
Markham, ON,
Canada L6C 2S3
Tel . 8 00- 66 8-9 00 8