Philips SILHOUETTE User Manual

Philips SILHOUETTE
SeriesT5 HO Extreme
emperature Lamps
T featuring ALTO
®
Lamp
deal for medium-bay
I and high-bay applications
ithout climate control
w
SILHOUETTE™SERIES
This lamp is better for the environment
because of its reduced mercur y content. All Philips ALTO
ptions which can simplify and reduce your
o lamp disposal costs depending on your state and local regulations.
®
lamps give you end-of-life
Improve your light quality while reducing your energy costs
Philips SILHOUETTE™Series T5 HO Extreme Temperature lamps are ideal for extreme temperature spaces for increased
energy savings*.
Provides extraordinary lumen output even in spaces without climate control
• Lumen output is > 90% from 65˚F to 170˚F (20˚C to 75˚C) due to amalgam technology
Reduced maintenance and disposal costs
• Long life for an extended relamping cycle
• 35,000 hours rated average life
• 92% lumen maintenance
• Warranty period: 36 months
Slim profile lamp and ballast
• Improved optical control
• Design flexibility
1,3
Sustainable lighting solution
• Reduces the impact on the environment: low mercury, energy efficiency and long life
(1,3, See back page for footnote)
* See Energy Savings char t on back
Philips SILHOUETTE™SeriesT5 HO Extreme Temperature lamps featuring ALTO®Lamp Technology
32˚F 50˚F 68˚F 86˚F 104˚F 122˚F 140˚F 158˚F 176˚F32˚F 50˚F 68˚F 86˚F 104˚F 122˚F 140˚F 158˚F 176˚F
0˚C 10˚C 20˚C 30˚C 40˚C 50˚C 60˚C 70˚C 80˚C0˚C 10˚C 20˚C 30˚C 40˚C 50˚C 60˚C 70˚C 80˚C
1
05
100
95
90
85
80
75
70
65
60
1
05
100
95
90
85
80
75
70
65
60
Ambient Temperature ˚C
(˚F)
Ambient Temperature ˚C
(˚F)
Relative Light Output (%)Relative Light Output (%)
Standard F54 T5 HO Lamps
T5 Extreme Temperature Lamps
0 5,000 10,000 15,000 20,000 25,000 30,000 35,0000 5,000 10,000 15,000 20,000 25,000 30,000 35,000
100%
98%
96%
94%
92%
90%
88%
100%
98%
96%
94%
92%
90%
88%
Lamp Operating HoursLamp Operating Hours
Light Output (%)Light Output (%)
Ordering, Electrical and Technical Data
tart
1
pprox.
A
3
umens
L
4
umens
L
5
C
RI Maint.
olor Nom. RatedAverage Life (Hrs.)
roduct Nom. Pkg. Temp. Length 3-hr 12-hr Initial Design Lumen
P
umber Description Watts Qty. (Kelvin) (In.) Start
N
E
1766-1 F54T5/835/HO/A/ALTO 54 40 3500 46 25,000 35,000 5000 4750 85 92%
2
E
1769-5 F54T5/841/HO/A/ALTO 54 40 4100 46 25,000 35,000 5000 4750 85 92%
2
1) Rated average life is the length of operation (in hours) at which point an average of 50% of a large sample of lamps will still be operational and 50% will not.
2) Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently.
3) Average life under engineering data with lamps turned off and restar ted once every 12 operating hours. Lamp life is appreciably longer if lamps are star ted less frequently.
4) Approximate initial lumens. The lamp lumen output is based upon lamp performance after 100 hour s of operating life, when the output is measured during operation on a high frequency reference ballast under standard laboratory conditions.For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The
allast factor is a multiplier applied to the designated lamp lumen output.
b
5) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast
nder standard laborator y conditions.
u
E
amp meets US Federal Minimum Efficiency Standards.
L
C
2
S
Energy Savings
Save up to 100 Watts when you upgrade to a 6 lamp T5HO System from a MH400 or MS360 HID System
nergy Savings with Energy Savings with
E
nergy Costs Based on Annual Operating Hrs
E
MH400 T5 54W HO T5 54W HO MS360 T5 54W HO T5 54W HO
460 System Watts 360 System Watts vs. MH400
Wh Rate 4380
k
0.06 $120.89 $241.78 $94.61 $189.22 $2,628 $5,256 $110.38 $220.75 $94.61 $189.22 $1,577 $3,154
$
*
**
760
8
*
380
4
**
760
8
00 Fixtures
1
380
4
*
760
8
nergy Costs Based on Annual Operating Hrs
E
420 System Watts 360 SystemWatts vs. MS360
**
*
380
4
**
760
8
*
380
4
$0.08 $161.18 $322.37 $126.14 $252.29 $3,504 $7,008 $147.17 $294.34 $126.14 $252.29 $2,102 $4,205 $0.10 $201.48 $402.96 $157.68 $315.36 $4,380 $8,760 $183.96 $367.92 $157.68 $315.36 $2,628 $5,256 $0.12 $241.78 $483.55 $189.22 $378.43 $5,256 $10,512 $220.75 $441.50 $189.22 $378.43 $3,154 $6,307 $0.20 $402.96 $805.92 $315.36 $630.72 $8,760 $17,520 $367.92 $735.84 $315.36 $630.72 $5,256 $10,512
Energy cost based on: (annual operating hours x kWh rate x system watts) ÷ 1,000
*
Based on 4,380 annual operating hours (12 hours per day/7 days per week)
*
*
ased on 8,760 annual operating hours (24 hours per day/7 days per week)
B
† Energy savings based on: (costs of MH400 - cost of T5 54W HO) x 100 fixtures.
† Energy savings based on: (cost of MS360 - cost of T5 54W HO) x 100 fixtures.
Above specifications subject to change without notice.
**
760
8
00 Fixtures
1
*
380
4
††
**
760
8
92% Lumen Maintenance
SILHOUETTE™SeriesT5 HO Extreme Temperature
© 2008 Philips Lighting Company.All rights reserved. Printed in USA 2/08
P-5924
www.philips.com
Performance (Relative Light Output vs.Temperature)
PhilipsT5 HO Extreme Temperature Lamps vs. Standard F54T5 Lamps
Philips Lighting Company 200 Franklin Square Drive P.O.Box 6800 Somerset, NJ 08875-6800 1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050
A Division of Philips Electronics Ltd.
Loading...