Philips SCF315/01 user manual

SCF315
User manual
Table of Contents
1 Important 3
Electromagnetic Fields (EMF) 5
Overview 6 Control panel 7
4 Assembling the electric
breast pump 8
5 Using the electric breast
pump 11
Before using the pump 11 To begin pumping 11 To pause pumping 15 Storing your breast milk 15 Feeding your baby with
expressed breast milk 16
9 Compatibility 18
10 Ordering accessories 19
11 Recycling 19
12 Guarantee and service 19
13 Troubleshooting 20
14 Important additional
information 22
6 Hints to help you succeed 17
7 When to express milk 18
Right times of the day to
express your milk 18
8 Storage 18

1 Important

Read this user manual carefully before using your Philips Avent single electric breast pump, and save the user manual for future reference. You can
also nd this user manual at Philips
website: www.philips.com/support.
Warning
• Always unplug from the power socket immediately after use.
• Do not use the breast pump while bathing.
• Do not place or store the breast pump where it can fall or be pulled into a bath or sink.
• Do not place or drop the pump motor, silicone tube, and power adapter into water or other liquids.
• Do not reach for a product that has fallen into water. Unplug from the power socket immediately.
• Children should be supervised to ensure that they do not play with the appliance. Place the appliance out of reach from children and pets.
• Before each use, check the breast pump, including the power adapter for signs of damage. Never operate the breast pump if it has a damaged plug, not working properly, has been dropped or damaged, or has been submerged in wate r.
• The power cord is irreplaceable. Discard it if is damaged, including the power adapter.
• Only use accessories recommended by Philips Avent.
• Only use the power adapter supplied with the product.
• Make sure the breast pump, including the power adapter, is not exposed to extreme heat or placed in direct sunlight.
• Do not use the breast pump outdoors.
• There are no user serviceable parts inside the pump. Do not attempt to open, service, or repair the breast pump yourself.
• The parts of the pump which come directly into contact with milk are personal care items, and should not be shared between mothers.
• Do not attempt to remove the pump body from the breast while under vacuum. Switch the
breast pump o, and break the
seal between your breast and
the pump funnel with your nger,
then remove the pump from your
breast. You can also pull o the
silicone tube from the motor or the cap to release the vacuum.
• Never use while pregnant as pumping can induce labor.
• Never use when sleepy or drowsy.
• This appliances can be used by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and if they understand the hazards involved.
• If expressing becomes painful, stop and consult your breast feeding advisor or healthcare professional.
- 3 -
• Do not use the breast pump in the
presence of ammable anaesthetic
mixtures with air, with oxygen, or with nitrous oxide.
• Although the breast pump is compliant with applicable EMC directives, it may still be susceptible to excessive emissions and/or may interfere with more sensitive equipment.
• Make sure not put any products on the pump motor, like pillow, blanket etc. Please make sure pump motor work in well ventilation and heat dissipation condition.
Caution
• The product should not be left unattended when plugged into a power socket.
• Never drop or insert any foreign object into any opening or the silicone tube.
• Do not shorten the silicone tube.
• Before you connect the breast pump to the power, make sure that the voltage of the product corresponds to the local power voltage.
• Wash, rinse, and sterilise the appropriate pump parts before each use.
• Do not use antibacterial, abrasive cleaners, or detergents when cleaning breast pump parts.
• Never put the breast pump motor in water or steriliser, as you can cause permanent damage to the pump.
• If the vacuum generated is uncomfortable or cause pain,
switch o the breast pump, break
the seal between the breast and
the pump funnel with your nger,
and then remove the pump from
your breast. You can also pull o
the silicone tube from the motor or the cap to release the vacuum.
• Do not continue pumping for more
than ve minutes at a time if no
result is achieved.
• Never use any accessories or parts from other manufacturers or that Philips Avent does not
specically recommend. If you use
such accessories or parts, your guarantee becomes invalid.
• Do not use the breast pump if the silicone diaphragm appears to be damaged or broken. Replace the silicone diaphragm. See chapter “Guarantee and service” for information on how to obtain replacement parts.
• Never use feeding teats as
dummies, paciers, or soothers.
Make sure that the teething baby does not bite the teat too long. The continuous and prolonged bite will damage the teat. For hygiene reasons, replace teats after three months of use. Use only Philips Avent teats and bottles together.
- 4 -
Batteries
This appliance can use both 1.5V AA non-chargeable batteries and rechargeable batteries. For instructions on how to replace the batteries, see chapter “Assembling the electric breast pump”.
• Rechargeable batteries are to be removed from the appliance before being charged.
Dierent types of batteries or new and used batteries are not to be mixed.
• Batteries are to be inserted with the correct polarity.
• Exhausted batteries are to be removed from the appliance and safely disposed of.
• If the appliance is to be stored unused for a long period, the batteries should be removed.
• The supply terminals are not to be short-circuited.

Electromagnetic Fields (EMF)

This Philips appliance complies with all applicable standards and regulations regarding exposure to electromagnetic
elds.

2 Introduction

Congratulations on your purchase and welcome to Philips Avent! To fully
benet from the support that Philips Avent oers, register your product at
www.philips.com/ welcome. The Philips Avent breast pump provides
comfort, convenience for eective
expression. It has an “Natural suckling” expression kit, an innovative funnel to
mimic natural suckling and compress your nipple and areola, to make whole expression more comfortable
and eective. Rhythmic Wave mimics
the fast/shallow & slow/deep way a baby suckles for faster let down
and continuous milk ow with closer
to natural sucking pacing. Doctors recommend that breast milk is the best nutrition for babies during the
rst year, combined with solid food after the rst six months, Your milk is
specially adapted to your baby’s needs and contains antibodies which help protect your baby against infection and allergies. Your electric breast pump will help you breast-feed longer. You can express and store your milk so that - whether you are out for a few hours, taking a well deserved rest, or back at work - your baby can still enjoy the
benets of your breast milk, even if
you cannot be there to give it yourself. As the pump is easy to assemble, silent and discreet, you can take it with you anywhere, allowing you to express milk at your own convenience and maintain your milk supply.
- 5 -

Overview

g
h
i
c
b ae df
n
j
k
Silicone tube
a
Cap
b
Silicone diaphragm
c
Pump body
d
Massage cushion
e
Pump cover
f
Valve (x2) (one for back up)
g
l
Dormal cap
h
Screw ring
i
Teat (0 m+)
j
Sealing disc
k
Bottle (125 ml)
l
Power adapter
m
Pump motor
n
- 6 -
m

Control panel

A
B C D
E
F
G
A Timer counting indicator H Level up button
B Stimulation indicator I Pause/play button
C Level 2 indicator J Level 4 indicator
D Level 1 indicator K Level 3 indicator
E Mode selection button (selecting
the stimulation and expression mode)
F Level down button M Battery indicator
G Power button
L Expression indicator
M
L K J
I
H
Note
The battery indicator ashes only when in low battery. We recomend you to
change the battery as soon as possible.