Philips SC1995/80 Usage notes [zh]

Lumea
SC1995
2
Hair color table / 毛发颜色表
3
5
9
8
2 3
4
13
14
7
6
11
10
1
12
1
English 6
简体中文
25
6
English

Welcome

Welcome to the beauty world of Lumea! You are only a few weeks away from silky-smooth skin.
Philips Lumea uses Intense Pulsed Light (IPL) technology, known as one of the most effective methods to continuously prevent hair regrowth. In close cooperation with licensed dermatologists we adapted this light-based technology, originally used in professional beauty salons, for easy and effective use in the safety of your home. Philips Lumea is gentle and offers convenient and effective treatment at a light intensity that you find comfortable. Unwanted hairs are finally a thing of the past. Enjoy the feeling of being hair-free and look and feel amazing every day.
To fully benefit from the support that Philips offers, register your product at
www.philips.com/welcome. For further information, please go to www.philips.com/lumea to find our experts' advice, tutorial videos and
FAQs and make the most of your Lumea.

Device overview (Fig. 1)

1 Light exit window with integrated UV filter 2 Body attachment 3 Reflector inside the attachment 4 Integrated safety system 5 Electronic contacts 6 Flash button 7 Opening for electronic contacts 8 On/off button 9 Intensity lights (1-5) 10 'Ready to flash' light 11 Air vents 12 Device socket 13 Adapter 14 Small plug 15 Pouch (not shown)

Who should not use Lumea? Contraindication

General conditions

-
Never use the device if you have skin type V or VI (You rarely to never sunburn, very dark tanning). In this case you run a high risk of developing skin reactions, such as hyperpigmentation and hypopigmentation, strong redness or burns.
Note: To check if your skin type allows usage of the device, consult the skin tone table with number 2 on the foldout page.
English
-
Never use the device if you are pregnant or breastfeeding as the device was not tested on pregnant or breastfeeding women.
-
Never use the device if you have any active implants such as a pacemaker, neurostimulator, insulin pump etc.

Medications/History

Never use the device if you take any of the medications listed below:
-
If your skin is currently being treated with or has recently been treated in the past week with Alpha-Hydroxy Acids (AHAs), Beta­Hydroxy Acids (BHAs), topical isotretinoin and azelaic acid.
-
If you have taken any form of isotretinoin Accutane or Roaccutane in the last six months. This treatment can make skin more susceptible to tears, wounds and irritations.
-
If you are taking photosensitizing agents or medications, check the package insert of your medicine and never use the device if it is stated that it can cause photo-allergic reactions, photo-toxic reactions or if you have to avoid sun when taking this medicine.
-
If you take anticoagulation medications, including heavy use of aspirin, in a manner which does not allow for a minimum 1-week washout period prior to each treatment.
7
Never use the device:
-
If you have received radiation therapy or chemotherapy within the past 3 months.
-
If you are on painkillers which reduce the skin's sensitivity to heat.
-
If you take immunosuppressive medications.
-
If you have had surgery in the areas to be treated in the last 3 weeks.

Pathologies/Disorders

Never use the device:
-
If you have diabetes or other systemic or metabolic diseases.
8
English
-
If you have congestive heart disease.
-
If you have a disease related to photosensitivity, such as polymorphic light eruption (PMLE), solar urticaria, porphyria etc.
-
If you have a history of collagen disorder, including a history of keloid scar formation or a history of poor wound healing.
-
If you have epilepsy with flashlight sensitivity.
-
If your skin is sensitive to light and easily develops a rash or an allergic reaction.
-
If you have a skin disease such as active skin cancer, you have a history of skin cancer or any other localized cancer in the areas to be treated.
-
If you have a history of vascular disorder, such as the presence of varicose veins or vascular ectasia in the areas to be treated.
-
If you have any bleeding disorder.
-
If you have a history of immunosuppressive disease (including HIV infection or AIDS).

Skin condition

Never use the device:
-
If you have infections, eczema, burns, inflammation of hair follicles, open lacerations, abrasions, herpes simplex (cold sores), wounds or lesions and haematomas in the areas to be treated.
-
On irritated (red or cut), sunburned, recently tanned or fake­tanned skin.
-
On the following areas without consulting your doctor first: moles, freckles, large veins, darker pigmented areas, scars and skin anomalies. This can result in a burn and a change in skin color, which makes it potentially harder to identify skin-related diseases.
-
On following areas: warts, tattoos or permanent make-up.

Location/areas

Never use the device on the following areas:
English
-
Around the eyes and on or near the eyebrows.
-
On the lips, nipples, areolas, labia minora, vagina, anus and the inside of the nostrils and ears.
-
Men must not use the device on the face and neck including all beard-growing areas, nor on the whole genital area.
-
On areas where you use long-lasting deodorants. This can result in skin reactions.
-
Over or near anything artificial like silicone implants, subcutaneous injection ports (for instance an insulin dispenser) or piercings.
Note: This list is not exhaustive. If you are not sure whether you can use the device, we advise you to consult your doctor.

Important

9

Danger

-
Keep the device and the adapter dry.
-
If the device is broken, do not touch any inner part to avoid electric shock.
-
Water and electricity are a dangerous combination. Do not use this appliance in wet surroundings (e.g. near a filled bath, a running shower or a filled swimming pool).

Warning

-
This device is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, unless they have been given supervision or instruction concerning use of the device by a person responsible for their safety.
10
English
-
Children should be supervised to ensure that they do not play with the device.
-
The device is not intended for children under the age of 15 years. Teenagers aged between 15 and 18 years can use the device with the consent and/or assistance of their parents or the persons who have parental authority over them.Adults of 18 years and older can use the device freely.
-
Always check the device before you use it. Do not use the device or adapter if it is damaged.
-
Do not use the device if the UV filter of the light exit window is broken.
-
Do not modify or cut off any part of the adapter or the cord, as this causes a hazardous situation.
-
Do not use any pencil or pen to mark the areas to be treated. This may cause burns on your skin.
-
Hair removal by intense pulsed light sources can cause increased hair growth in some individuals. Based upon currently available data, the highest risk groups for this response are females of Mediterranean, Middle Eastern and South Asian heritage treated on the face and neck.
-
The light exit window can become very hot after use. Do not touch the inner part of the light exit window before it has cooled down.
-
This appliance runs on electric power. You need to leave the adapter connected to a wall socket to operate the appliance. This adapter provides extra features to ensure safe operation and shall not be replaced by another type of adapter. Only use the detachable supply unit (S036NV2400150) provided with this appliance (see symbol).
Note: If you notice a skin tone has changed since the last treatment (e.g. due to tanning), we recommend that you perform a skin test and to wait 30 minutes before your next treatment.
English

To prevent damage

-
Make sure that nothing obstructs the airflow through the ventilation slots of the device.
-
Never subject the device to heavy shocks and do not shake or drop it.
-
If you take the device from a very cold environment to a very warm environment or vice versa, wait approximately 3 hours before you use it.
-
Store the device in a dust free and dry place.
-
Do not expose the device to temperatures lower than 15°C or higher than 35°C during use.
-
To prevent damage, do not expose the device to direct sunlight or UV light for several hours.

Caution

-
This device is only intended for removing unwanted body hair from areas below the cheekbone. Do not use it for any other purpose.Doing so may expose you to a hazardous situation.Men most not use it on the face and neck including all beard-growing areas and the whole genital area.
11
-
This device is not washable. Never immerse the device in water and do not rinse it under the tap.
-
For hygienic reasons, the device should only be used by one person.
-
Use the device only at settings suitable for your skin type. Use at higher settings than those recommended can increase the risk of skin reactions and side effects.
-
Never use compressed air, scouring pads, abrasive cleaning agents or aggressive liquids such as petrol or acetone to clean the device.
12
English
-
The scattered light produced by the device is harmless to your eyes. Do not look at the flash while using the device. It is not necessary to wear goggles during use. Use the device in a well-lit room so that the light is less glaring to your eyes.
-
Always return the device to a service center authorized by Philips for examination or repair. Repair by unqualified people could cause an extremelyhazardous situation for the user.
-
Never leave the device unattended when it is switched on. Always switch off the device after use.
-
Do not use the device if any of the conditions mentioned in chapter ‘Who should not use Lumea? Contraindication' apply to you.
-
Tanning with natural or artificial sunlight might influence the sensitivity and color of your skin. Perform a skin test to determine the appropriate light intensity setting.
-
Before you use Lumea, you should clean your skin and make sure it is hair-free, entirely dry and free from oily substances.
-
Do not treat the same skin area more than once during a session. This does not improve the effectiveness of the treatment, but increases the risk of skin reactions.
-
Lumea should never be painful. If you experience discomfort, reduce the light intensity setting.

Electromagnetic fields (EMF)

This Philips device complies with all applicable standards and regulations regarding exposure to electromagnetic fields.

How IPL works

With IPL technology, gentle pulses of light are applied to the skin and absorbed by the hairroot. The darker the hair, the better the pulses of light are absorbed.
The pulses of light stimulate the hair follicle to go into a resting phase. As a consequence, the hair sheds naturally and hair regrowth is prevented, leaving your skin continuously silky-smooth.
The cycle of hair growth consists of different phases. IPL technology is only effective when the hair is in its growing phase.Not all hairs are in the growing phase at the same time. This is why we recommend an 8-week treatment schedule followed by touch-ups to make sure all hairs are effectively treated in the growing phase..
Note: Treatment with Lumea is not effective if you have blond or light blond hairs, as light hairs do not absorb enough light. Below you can see the hair colors for which Lumea is suitable and effective.

Suitable body hair colors

Note: To check if your body hair color allows usage of the device, consult the hair color table with number 3 on the foldout page.
English
13

What to expect

Immediately after the 1st treatment

Afterthe first treatment, it can take 1 to 2 weeks for the hairs to fall out. In the first weeks following the initial treatments, you still see some hairs growing.These are likely to be hairs that were not in their growing phase during the first treatments.

After 2-3 treatments

After 2-3 treatments, you should see a noticeable reduction in hair growth. However, to effectively treat all hairs, it is important to keep on treating according to the recommended treatment schedule.

After 4-5 treatments

After 4-5 treatments, you should see a significant reduction of hair growth in the areas that you treated with Lumea. A reduction of hair density should be visible as well. Keep on treating with frequent touch-ups (every 4-8 weeks)to maintain the result.
14
English

Tanning advice

Tanning with natural or artificial sunlight

Intentionally exposing your skin to natural or artificial sunlight with the aim of developing a tan influences the sensitivity and color of your skin. Therefore the following is important:
-
After each treatment, wait at least 48 hours before tanning. Even after 48 hours, make sure that the treated skin does not show any redness from the treatment anymore.
-
In case of exposing your skin to the sun (without tanning intentionally) in the 48 hours after treatment, use a sunblock SPF 50+ on the treated areas. After this period, you can use a sunblock SPF 30+ for two weeks.
-
After tanning, wait at least 2 weeks before you use Lumea. Perform a skin test to determine the appropriate light intensity setting.
-
Do not use Lumea on sunburned body areas. Note: Occasional and indirect sun exposure does not qualify as tanning.

Tanning with creams

If you have used an artificial tanning lotion, wait until the artificial tan has disappeared completely before you use the device.

Before you use your Lumea

Pretreating your skin

Before you use Lumea, you should pretreat your skinby removing hairs on the surface of your skin. This allows the light to beabsorbed by the hair parts below the skin surface to ensure effective treatment. You can either shave, short-trim, epilate or wax. Do not use depilatory creams, as chemicals may cause skin reactions.
If you chose to wax, please wait 24 hours before using Lumea to let your skin rest.We recommend that you take a shower before the treatment to ensure that all possible residue of wax has been removed from your skin.
1 Pretreat the areas you intend to treat with Lumea. 2 Clean your skin and make sure it is hair-free, entirely dry and free from
oily substances. Note: Once the hairs stop growing back, which usually happens after 4-5
treatments, you no longer have to pretreat your skin before you use the device.

Skin test

When you use Lumea for the first time or after recent tanning, perform a skin test on each area to be treated. The skin test is necessary to check your skin's reaction to the treatment and to determine the correct light intensity setting for each bodyarea.
1 Choose an area close to the area you intend to treat. 2 Switch on the device. Make sure you select setting 1. 3 Put the device against your skin and press the flash button to release a
flash.
4 Slide the device over the skin to the next area to be treated. 5 Increase the setting by one level, apply a flash and slide the device to the
next area. Repeat this for all levels within the recommended range for your skin type.
6 After the skin test, wait 24 hours and check your skin for any reaction. If
your skin shows reactions, choose the highest setting that did not result in any skin reaction for subsequent use. The skin test should be performed in all the areas you want to treat.

Using your Philips Lumea

Placing and removing

To place the attachment, simply snap it onto the light exit window.
English
15
To remove the attachment, pull it off the light exit window.

Selecting the right light intensity

Lumea provides 5 different light intensities. Depending on your skin type and the light intensity level you find comfortable, you can select the right light intensity setting.
1 Consult the table below to select the right setting.
16
English
2 To adjust the light intensity setting,press the on/off button one or more
times until you have reached the required setting. The corresponding intensity light lights up white.
3 Lumea should never be painful. If you experience discomfort, reduce the
light intensity setting.
4 After recent tanning, perform a skin test to determine the right light
intensity setting.
Skin type
I White; You always sunburn,
II Beige; You easily sunburn, tan
III Light brown; You sunburn easily,
IV Mid brown; You rarely sunburn,
V Dark brown; You rarely sunburn,
VI
Note: To check if your skin type allows usage of the device, consult the skin tone table with number 2 on the foldout page.
Note:Your skin may react differently on different days/occasions for a number of reasons.
Skin tone Light intensity setting
never tan.
minimally.
tan slowlyto light brown.
tan easily.
tan very easily.
Brownish black or darker; You rarelyor never sunburn, very dark tanning.

Handling the device

1 Before use, clean the attachment and the light exit window. 2 Put the small plug in the device and put the adapter in the wall socket. 3 Switch on the device and select the right light intensity for your skin tone.
4/5
4/5
4/5
3/4
You cannot use the device
You cannot use the device
English
4 Place the device at a 90° angle on the skin so that the attachment and
the integrated safety system are in contact with your skin. The integrated safety system prevents unintentional flashingwithout skin
contact..
5 Press the devicefirmly onto your skin to ensureproper skin contact. The
‘ready to flash light’on the back of the device lights up green to indicate that you can proceed with the treatment.
6 Press the flash button to release a flash.You should feel a warm
sensation because of the flash. Note:The light produced by the device is harmless to your eyes. It is not
necessary to wear goggles during use. Use the device in a well-lit roomso that the light is less glaring to your eyes.
7 Place the device on the next area to be treated. After each flash, it takes
up to 3.5 seconds until the device is ready to flash again. You can release a flash when the 'ready to flash' light lights up again.
17
8 To make sure that you have treated all areas, release the flashes close to
each other. Effective light only comes out of the light exit window, therefore there should be some overlap.However, make sure you flash the same area only once. Flashing the same area twice doesn't improve the effectiveness of the treatment, but increases the risk of skin reactions.
9 When you have finished the treatment, press and hold the on/off button
for 2 seconds to switch off the device.

Treatment modes: Stamp & Flash and Slide & Flash

Philips Lumea has two treatment modes for more convenient use on different body areas:
-
The Stamp & Flash mode (available for SC1995, SC1993) is ideal to treat small orcurvy areas like knees and underarms. Simply press and releasethe flash button to release a single flash.
-
The Slide & Flash mode (only available for SC1995) offers convenient use on larger areas like legs. Keep the flash button pressed while you slide the device over your skinto release several flashes in a row.
18
English

Recommended treatment schedule

Initial phase

For the first 4 to 5 treatments, we advise you to use Philips Lumea once every two weeks to ensure that all hairs are treated.

Touch-up phase

After the initial treatment phase (4-5 treatments), we recommend touch-ups every 4 to 8 weeks,when you see hairs growing back. This is to maintain results and enjoy smooth skin for months.The time between treatments may vary based on your individual hair regrowth and also across different body areas.

Treatment time per area

1 2 3
2
1
8 min.
1 min.
3
1 14 min.
1
1
4 min.
1 min.
English
19

After use

Common skin reactions

Your skin may show slight redness and/or may prickle, tingle or feel warm. This reaction is absolutely harmless and disappears quickly.
Dry skin and itching may occur due to shaving or a combination of shaving and light treatment. You can cool the area with an ice pack
20
English
or a wet face cloth. If dryness persists, you can apply a non-scented moisturizer on the treated area 24 hours after the treatment.

Rare side effects

-
Burns, excessive redness (e.g. around hair follicles) and swelling: these reactions occur rarely. They are the result of using a light intensity that is too high for your skin tone. If these reactions do not disappear within 3 days, we advise you to consult a doctor. Wait with the next treatment until the skin has healed completely and make sure you use a lower light intensity.
-
Skin discoloration: this occurs very rarely. Skin discoloration manifests itself as either a darker patch (hyperpigmentation) or a lighter patch (hypopigmentation) than the surrounding area. This is the result of using a light intensity that is too high for your skin tone. If the discoloration does not disappear within 2 weeks, we advise you to consult a doctor. Do not treat discolored areas until the discoloration has disappeared and your skin has regained its normal skin tone.
-
Skin infection is very rare but is a possible risk following a (micro)wound, a skin burn, skin irritation etc.
-
Epidermal heating (a sharply defined brownish area which often occurs with darker skin tones and is not accompanied with skin dryness): This reaction occurs very rarely. In case this reaction does not disappear within 1 week, we advise you to consult a doctor. Wait with the next treatment until the skin has healed completely and make sure you use a lower light intensity.
-
Blistering (looks like small bubbles on the surface of the skin): this occurs very rarely. In case this reaction does not disappear within 1 month or when the skin gets infected, we advise you to consult a doctor. Wait with the next treatment until the skin has healed completely and make sure you use a lower light intensity.
-
Scarring: often the secondary effect of a burn, which can take longer than a month to heal.
English
-
Folliculitis (swelling around hair follicles combined with pustule formation): this reaction occurs very rarely and is the result of bacteria penetrating the damaged skin. In case this reaction occurs, we advise you to consult a doctor as folliculitis may need antibiotic ointment.
-
Excessive pain: this can occur during or after treatment if you have used the device on skin that is not hair-free, if you use the device at a light intensity that is too high for your skin tone, if you flash the same area more than once and if you use the device on open wounds, inflammations, infections, tattoos, burns, etc.

Aftercare

After use, you can safely apply lotions, creams, deodorant, moisturizer or cosmetics to the treated areas. If you experience skin irritation or skin redness after treatment, wait until it disappears before applying any product to your skin. If you experience skin irritation after applying a product to your skin, wash it off with water.
Note: when following all instructions you may still get skin reactions. In this case stop using the device and contact the consumer care center in your country.
21

Cleaning & storage

1 After use, switch off the device, unplug it and let it cool down. 2 Remove the attachment.
3 Moisten the soft cloth supplied with the device with a few drops of water
4 Let all parts air dry thoroughly. 5 Store the device in a dust-free and dry place at a temperature between
and use it to clean the following parts:
-
the light exit window
-
the outside surface of the attachment
-
the reflector inside the attachment
-25 °C and 60 °C.
22
English

Warranty and support

If you need information or support, please visit www.philips.com/support or read the international warranty leaflet.

Recycling

-
This symbol means that this product shall not be disposed of with normal household waste (2012/19/EU).
-
Follow your country's rules for the separate collection of electrical and electronic products. Correct disposal helps prevent negative consequences for the environment and human health.

Technical specifications

SC1995, SC1993
Rated voltage 100 V-240 V
Rated frequency 50 Hz-60 Hz
Rated input 36 W
Protection against electric shock Class II
Protections rating IP 30 (EN 60529)
Operating conditions Temperature:+15 °C to 35°C
Storage conditions temperature -25 °C to 70 °C
Storage conditions humidity
Operating pressure 700 hPa - 1060 hPa
Altitude Max. 3000 m
Emitted wavelengths 530 nm - 1400 nm
Optical exposure 2.5 - 5.0 J/cm², depending on chosen setting
Maximum optical energy 20 J
Pulse duration
Repetition time 1-3.5 s, depending on chosen setting
Optical homogeneity
Less than 90% (non condensing)
<1.5 ms
Max. +/- 20% deviation from average optical exposure in treatment area

Troubleshooting

This chapter summarizes the most common problems you could encounter with the device. If you are unable to solve the problem with the information below, visit www.philips.com/support for a list of frequently asked questions or contact the Consumer Care Center in your country.
Problem Possible cause Solution
English
23
The device/adapter becomes warm during use
The 'ready to flash light' doesn't light up when I place the attachment on my skin, but the cooling fan works.
The 'ready to flash light' lights up green but the device does not produce a flash when I press the flash button.
I cannot increase or decrease the light intensity settings/All intensity lights are blinking alternately
strange smell.
The skin feels more sensitive than usual during treatment/ I experience discomfort when I use the device.
This is normal. No action required.
The overheat protection has been activated.
The device needs to be reset. To reset the device, switch it off and
The device needs to be reset. To reset the device, switch it off and
The attachment or the filter glass is dirty.
You have not removed the hairs on the area to be treated properly. These hairs may get burned and can cause the smell.
The light intensity setting you use is too high.
You did not remove the hairs on the areas to be treated.
When the overheat protection has been activated, the fan still works. Do not switch off the device, but let it cool down for approx.15 minutes before you continue to use it.
switch it on again.
switch it on again.
Clean the attachment carefully.The device produces a
Pretreat your skin before you use Lumea.
Check if you have selected the right light intensity setting. If necessary, select a lower setting.
Pretreat your skin before you use Lumea.
The UV filter of the light exit window is broken.
You treated an area for which the device is not intended.
If the UV filter is broken, do not use the device anymore. Contact the Consumer Care Center in your country, your Philips dealer or a Philips service center.
Never use the device on the following areas:the face, inner labia, anus, nipples, areolas, lips,inside the nostrils and ears, around the eyes and near the eyebrows. Men must not use it on the face, neck or on the scrotum.
24
English
Problem Possible cause Solution
The skin reaction after treatment lasts longer than usual.
The results of the treatment are not satisfactory.
My body attachment does not have an integrated glass/filter/window.
The device is not suitable for your skin tone.
You have used a light intensity setting which is too high for you.
You have used a light intensity setting which is too low for you.
You did not flash an area adjacent to an area you treated before.
The device is not effective on your body hair color.
You do not use the appliance as often as recommended.
You respond more slowly to IPL treatment.
This is normal. The body attachment does not contain a
Do not use the device if you have skin type VI or V, a brownish black or darker skin tone.
Select a lower intensity next time.Seechapter 'Using your Philips Lumea', section 'Selecting the right light intensity'.
Select a higher setting next time.
You have to release the flashes close to each other.
If you have light blond, blond, or red hair, the treatment is not effective.
To remove all hairs successfully, we advice you to follow the recommended treatment schedule. You can reduce the time between treatments, but do not treat more often than once every two weeks.
Continue using the device for at least 6 months, as hair regrowth can still decrease over the course of this period.
glass/filter/window.
欢迎
欢迎来到 Lumea 的美容世界! 只需几周您就能获得如丝般光滑的皮肤。 飞利浦 Lumea 采用强脉冲光 (IPL) 技术,这是一种为我们所知的最有效的持续防
止毛发再生的方法之一。 通过与执业皮肤科专家密切合作,我们对这种最初用于 专业美容沙龙的光学技术进行了改进,使您可以在自己的家中安全、便捷、有效地 使用这种技术。 飞利浦 Lumea 光照柔和,照射便捷、有效,光强让人感觉非常舒 适。 让您尽享摆脱毛发的愉悦感受,每天焕发迷人光彩。
为了您能充分享受飞利浦提供的支持,请在下面的页面注册您的产品 www.philips.com/welcome。 有关具体信息,请转到 www.philips.com/lumea 查 阅专家建议、教学视频和常见问题解答,了解如何充分利用您的 Lumea。
设备概述(图 1)
1 带集成式紫外线滤光器的透光窗口 2 身体修剪附件 3 附件内部的反光镜 4 集成式安全系统 5 电子触点 6 闪光按钮 7 电子触点开口 8 开/关按钮 9 光强 (1-5) 10 闪光指示灯 11 透气孔 12 设备插座 13 适配器 14 小插头 15 软袋(未显示)
简体中文
25

哪些人不应使用 Lumea? 禁忌

一般状况

-
如果您是 V 型或 VI 型皮肤(极少甚至从不晒伤,美黑得很深),切勿使 用本设备。 在这种情况下,发生皮肤反应的风险非常高,例如色素沉着 和色素减退、严重发红或灼伤。
注意: 如需确认您的皮肤类型是否适合使用本设备,请查阅插页中的 2 号 肤色表。
-
由于本设备未针对孕妇或哺乳期妇女进行测试,切勿对这类人使用本设 备。
26
简体中文
-
如果您体内植入了任何有源植入式装置(如心脏起搏器、神经刺激器或 胰岛素泵等),切勿使用本设备。

用药情况/病史

使用下列任何药物的人员切勿使用本设备:
-
皮肤目前或在过去一周内使用了果酸 (AHA)、水杨酸 (BHA)、外用异维 A 酸和杜鹃花酸。
-
在最近六个月内曾使用任何形式的异维 A Accutane Roaccutane 此照射会使皮肤更容易裂开、损伤及刺痛。
-
如果您正在服用光敏剂或光敏药物,请检查药物的包装说明书,如果其 中明确指出该药物可能造成光过敏反应、光毒性反应或在服药期间要避 免日晒,请切勿使用本设备。
-
如果使用抗凝血药物,包括大量使用阿司匹林,要求在每次处理前至少 1 周不得冲洗伤口。
在以下条件下切勿使用本设备:
-
如果您在过去 3 个月内曾接受过放疗或化疗。
-
如果您服用了会降低皮肤对热的敏感性的止痛药。
-
服用了免疫抑制药。
-
需要照射的部位在最近 3 周内动过手术。

病理/病症

在以下条件下切勿使用本设备:
-
患有糖尿病或其他全身性或代谢性疾病。
-
患有充血性心脏病。
-
患有与光过敏相关的疾病,如多形性日光疹 (PMLE)、日光性荨麻疹、 卟啉症等。
-
曾患有胶原代谢紊乱,包括癍痕瘤形成史或伤口愈合不良史。
-
患有闪光过敏性癫痫症。
-
您的皮肤对光敏感且容易产生皮疹或过敏反应。
-
需要照射的部位患有皮肤病(如活性皮肤癌),或曾患有皮肤癌或任何 其他局部癌症。
-
曾患有血管疾病,如在照射部位患有静脉曲张或血管扩张症。
-
患有任何出血病症。
简体中文
-
曾患有抑制免疫反应疾病(包括 HIV 感染或艾滋病)。

皮肤状况

在以下条件下切勿使用本设备:
-
需要照射的部位患有感染、湿疹、烧伤、毛囊发炎、开放性撕裂伤、擦 伤、单纯疱疹(唇疱疹)、伤口或病变和血肿。
-
在过敏(红肿或破损)、晒伤、近期做过美黑或伪美黑的皮肤上使用。
-
在未先行咨询医生的情况下,在以下区域使用: 痣、雀斑、大静脉、色 素较深的部位、疤痕和皮肤异常的部位。 这可能会引起皮肤灼伤和肤色 改变,从而可能会更难确诊皮肤相关疾病。
-
在以下区域使用: 疣体、纹身或永久性妆饰上使用。

区域/部位

切勿在以下部位使用本设备:
27
-
双眼周围和眉毛之上或附近。
-
嘴唇、乳头、乳晕、小阴唇、阴道和肛门上以及鼻孔和耳朵内侧。
-
男士切勿在面部和颈部(包括所有长胡须的部位)和整个生殖部位使用 本设备。
-
在使用了长效香体液的部位使用。 这可能造成皮肤反应。
-
在任何人造植入物之上或附近,如硅胶植入物、皮下注射针头(例如胰 岛素分配器)或穿洞。
注意: 此列表并不详尽。 如果您不确定是否可以使用本设备,建议您咨询 医生。
28
简体中文

注意事项

危险
-
使本设备和适配器保持干燥。
-
警告符号注释:禁止在洗澡或淋浴时使用。
-
警告:不要在盛水的浴缸、淋浴、洗脸盆或其他器皿附近使用本器具。
-
一旦设备损坏,请勿触摸任何内部部件,以免触电。
-
水与电接触极其危险。 请勿在潮湿环境中(如盛满水的浴缸、开着的淋 浴器或注满水的游泳池附近)使用本产品。
警告
-
本设备不打算由肢体不健全、感官或精神有障碍的人(包括儿童)使用 ,除非有负责他们安全的人对他们使用本设备进行监督或指导。
-
应照看好儿童,确保他们不摆弄本设备。
-
本设备不适合 15 周岁以下儿童使用。 15 18 周岁的青少年可以在得到 其父母或监护人的同意和/或协助的情况下使用本产品。18 周岁及以上 的成年人可以自主使用本设备。
-
使用前,请务必检查设备。 如果本设备或适配器发生损坏,请勿再使用 。
-
如果透光窗口的紫外线滤光器损坏,请勿再使用本设备。
-
请勿改装或切割适配器的任何部件或线缆,因为这会导致严重后果。
-
请勿使用任何铅笔或钢笔标记要照射的部位。 这可能会导致皮肤烧伤。
-
如果您的肤色较深,那么在照射完肤色较浅部位后立即照射肤色较深部 位时请务必当心。 肤色传感器可能不会立即阻止对肤色较深部位的照射 。
-
通过激光或强脉冲光源脱毛可能会导致某些人毛发增生。 根据最近的数 据来看,可能会出现此反应的最高风险人群是具有地中海、中东和南亚 血统的女性(照射面部和颈部)。
-
透光窗口在使用后会变得滚烫。 在透光窗口冷却之前,切勿触摸透光窗 口的内部部件。
简体中文
29
注意: 如果您发现肤色在上一次照射(例如进行美黑)之后发生了改变, 我们建议您进行皮肤测试并等待 30 分钟后再进行下一次照射。

为防止损坏,请遵循以下几点

-
确保设备通风槽气流畅通无阻。
-
请勿猛烈撞击、摇晃或跌落本设备。
-
如果将本设备从低温环境转移到高温的环境,请等待约 3 小时后再使用 ,反之亦然。
-
将本设备存放在无尘、干燥的地方。
-
在使用过程中,切勿将本设备置于低于 5°C 或高于 35°C 的环境中。
-
请勿将本设备直接曝晒于阳光下或紫外线下长达数小时,以免损坏。
警告
-
本设备仅适用于除去颧骨以下部位的多余体毛。 请勿将本设备用于其他 目的,否则可能会让您遭遇危险。男士切勿在面部和颈部(包括所有长 胡须的部位)和整个生殖部位使用本设备。
-
本设备不可水洗。 请勿将设备浸入水中,也不要在水龙头下冲洗。
-
警告符号注释:禁止用在打开的水龙头下进行清洗。
-
出于卫生考虑,此设备只应供一人使用。
-
请只在适合您皮肤类型的设置下使用本设备。 使用高于推荐设置的设置 可能增加皮肤反应和副作用的风险。
-
切勿使用压缩气体、钢丝绒、研磨性清洁剂或汽油、丙酮等腐蚀性液体 清洁本设备。
-
本设备发出的散射光对眼睛无害。 使用本设备时,请勿直视闪光。 使用 时无需佩戴护目镜。 请在光照条件良好的房间内使用本设备,以减少光 线对眼睛造成的眩目感。
-
本设备应送往由飞利浦授权的服务中心检查或维修。 由不合格人员进行 维修可能将用户置于极度危险的境地。
-
打开电源后,本产品不得无人看管。 使用后,务必关闭产品电源。
-
如果您存在“禁忌、注意事项和警告”一章中“禁忌”部分提及的任一身体状况,请勿使用产品。
-
自然光或人造光美黑可能会影响皮肤的敏感度和颜色。 应进行皮肤测试以确定合适的光强设置。
30
简体中文
-
在使用 Lumea 前,应清洁皮肤,确保皮肤上没有毛发、完全干燥且没有任何油性物质。
-
照射期间,请勿在相同皮肤区域照射多次。 这样并不会提高照射的效果,反而会增加皮肤反应的风险。
-
在使用 Lumea 时不应有任何痛苦的感觉。 如果您感觉不舒适,应降低光强设置。

电磁场 (EMF)

本飞利浦设备符合所有有关暴露于电磁场的适用标准和法规。

IPL 工作原理

在 IPL 技术的作用下,柔和的光脉冲照射在皮肤上并被发根吸收。 毛发越黑,光 脉冲的吸收就越好。
光脉冲能刺激毛囊进入休眠期。 因此,毛发会自然脱落,从而防止毛发再生,让 您的皮肤始终如丝般光滑。

适用的毛发颜色

毛发生长周期包含不同的阶段。 IPL 技术仅在毛发处于生长阶段有效。并非所有 毛发都同时处于生长阶段。 为此,我们建议采用一个 8 周的照射方案,然后进行 修剪以确保所有毛发在生长阶段得到有效照射。.
注意: 如果您的毛发为淡金色,使用 Lumea 照射不会有效果,因为浅色毛发不能 吸收足够的光。 下面列出了适合使用 Lumea 并有效果的毛发颜色。
注意: 如需确认您的毛发颜色是否适合使用本设备,请查阅插页中的 3 号毛发颜 色表。

预期效果

第一次照射后的即时效果

第一次照射后,可能需要 1 到 2 周毛发才会脱落。 在初次照射后的前几周内, 您仍会看到一些毛发在生长。这些有可能是在第一次照射时未处于生长阶段的毛 发。

照射 2-3 次后

照射 2-3 次后,您应该会看到毛发生长明显减少。 但是,为有效地照射所有毛 发,一定要根据推荐的照射方案持续照射。

照射 4-5 次后

照射 4-5 次后,您应该会看到用 Lumea 照射的部位毛发生长显著减少。 还应看到 毛发密度降低。 在不断照射的同时应经常修剪(每隔 4-8 周)以保持效果。

美黑建议

自然光或人造光美黑

如果为了得到美黑效果而有意将皮肤暴露在自然光或人造光之下,可能影响皮肤的 敏感度和颜色。 因此,以下做法非常重要:
-
每次照射后等待 48 小时再进行美黑。 即便在 48 小时后,也应确保照射后的皮 肤不再因照射而发红。
-
如果需要在照射后 48 小时内将皮肤暴露在阳光下(并非有意美黑),可以在 照射部位涂抹 SPF 50+ 防晒霜。 在这段时间过后,可以涂抹 SPF 30+ 防晒霜 两周。
-
美黑后应至少等待 2 周再使用 Lumea。 应进行皮肤测试以确定合适的光强设 置。
-
请勿在晒伤的身体部位使用 Lumea。 注意: 偶尔和间接性的暴露在阳光下不应算是美黑。
简体中文
31

乳霜美黑

如果您使用了人造美黑霜,应等到人造美黑霜完全消失后再使用本设备。
32
简体中文

在使用 Lumea 前

皮肤预处理

在使用 Lumea 前,应对皮肤进行预处理,除去皮肤表面的毛发。 这可以让皮肤表 面下的毛发部分吸收光照以确保照射效果。 您可以剃毛、剪短、脱毛或用蜡除 毛。 请勿使用脱毛膏,因为化学制剂可能引起皮肤反应。
如果您选择用蜡脱毛,请等待 24 小时后再使用 Lumea,以便让皮肤得到休息。 我们建议您在照射前先洗澡,以确保去除皮肤上所有可能残留的蜡。
1 对您希望使用 Lumea 照射的部位进行预处理。 2 清洁皮肤,确保皮肤上没有毛发、完全干燥且没有任何油性物质。
注意: 当毛发停止再生后(通常在 4 到 5 次照射之后),使用本设备之前无需 再对皮肤进行预处理。

皮肤测试

如果是首次使用 Lumea 或近期进行过美黑,应对每个准备照射的部位进行皮肤测 试。 之所以需要进行皮肤测试,是为了检查皮肤对照射是否存在反应,并确定每 个身体部位的正确光强设置。
1 在待照射部位附近选择一个部位。 2 打开设备。 确保选择设置 1。 3 将设备放在皮肤上,按下闪光按钮发出闪光。 4 将设备贴着皮肤滑动至下一个需要照射的部位。 5 将设置提高一级,发出一次闪光,然后将设备滑动至下一个部位。 对自己皮肤
类型的推荐光强范围内的所有级别重复此操作。
6 皮肤测试后,等待 24 小时,检查您的皮肤是否发生任何反应。 如果您的皮肤
出现反应,此后使用时请选择不会导致皮肤反应的最高设置。

使用飞利浦 Lumea

安装和取下

若要安装附件,只需将其按到透光窗口上即可。
若要取下附件,将其从透光窗口上拉下。
选择合适的光强
Lumea 提供 5 种不同的光强。 您可以根据自己的皮肤类型和感觉舒适的光强级别 选择适合的光强设置。
1 请参照下表选择合适的设置。 2 若要调节光强设置,请按开/关按钮一次或多次,直至达到所需的设置。 相应
的光强指示灯将亮起并发出白光。
3 在使用 Lumea 时不应有任何痛苦的感觉。 如果您感觉不舒适,应降低光强设
置。
4 如果近期做过美黑,应进行皮肤测试以确定合适的光强设置。
简体中文
33
皮肤类型
I 白色;总是被晒伤,不会变黑。 4/5
II 米色;容易被晒伤,会变成很浅的
III 浅褐色;容易被晒伤,美黑速度较
IV 中褐色;很少被晒伤,美黑较容易。3/4
肤色 光强设置
4/5
黑色。
4/5
慢,会变为浅褐色。
34
简体中文
V 深褐色;很少被晒伤,美黑非常容易。您无法使用本设备
VI

处理设备

棕黑色或更深的颜色;很少或从不 会被晒伤,深黑色。
注意: 如需确认您的皮肤类型是否适合使用本设备,请查阅插页中的 2 号肤色 表。
注意:由于各种原因的存在,您的皮肤可能因不同的照射天数/场合出现不同的反 应。
1 使用前请清洁附件和透光窗口。 2 将小插头插入设备,然后将适配器插入墙上插座。 3 打开设备,根据您的肤色选择合适的光强。
4 将设备成 90°角放在皮肤上,使附件和集成式安全系统与皮肤接触。.
集成式安全系统可防止在未与皮肤接触时意外地闪光。.
您无法使用本设备
5 将设备紧靠在皮肤上,以确保与皮肤可靠地接触。 当设备背面的“准备闪
光”指示灯亮起并呈绿色时,表明您可以进行照射了。

推荐照射方案

简体中文
6 按下闪光按钮发出一次闪光。由于闪光的缘故,您会感觉到微热。
注意:本设备发出的光对眼睛无害。 使用时无需佩戴眼睛。 请在光照条件良好 的房间内使用本设备,以减少光线对眼睛造成的眩目感。
7 将设备置于下一个需要照射的部位。 每次闪光后,设备需要 3.5 秒的时间才可
以再次闪光。 当“准备闪光”指示灯再次亮起时,您就可以发出闪光了。
8 为确保照射到所有部位,应在相互靠近的部位发出闪光。 由于只有透光窗口中
发出的光有效,因此应有一定的重叠。但是,应确保对同一部位只闪一次光。 对同一部位闪两次光并不会提高照射的效果,反而会增加皮肤反应的风险。
9 完成照射后,按住开/关按钮 2 秒钟关闭设备。
35

护理模式: 标记和闪光,以及滑动和闪光

飞利浦 Lumea 具有两种照射模式,可以更加方便地在不同的身体部位上使用:
-
标记和闪光模式(SC1995、SC1993 配备)非常适合于照射膝盖和腋下等较小 或曲面部位。 只需按下再松开闪光按钮即可发出一次闪光。
-
滑动和闪光模式(仅 SC1995 配备)可以方便地用于腿部等较大面积部位。 在 皮肤上滑动设备时按住闪光按钮即可发出一连串闪光。

初始阶段

在进行前 4 到 5 次照射时,建议您每两周使用一次飞利浦 Lumea,以确保所有毛 发得到照射。

修剪阶段

初始照射阶段(4-5 次照射)结束后,如果看到毛发重新生长,建议每隔 4 到 8 周 进行修剪。 这是为了保持效果并让皮肤数月保持光滑。照射的间隔时间可以根据 个人毛发再生速度和不同的身体部位进行调整。
1 2 3
2
1
8 min.
1 min.
3
1 14 min.
1
1
4 min.
1 min.
36
简体中文

每个部位的照射时间

使用后

常见的皮肤反应

皮肤可能会轻微发红和/或感到刺痒、刺痛或温热。 这种反应对身体完全无害,很 快就会消失。
剃毛或剃毛和光子脱毛结合进行可能出现皮肤干燥和发痒。 您可以使用冰袋或湿 毛巾冷却此部位。 如果干燥现象持续不消退,在照射 24 小时后可以在照射部位涂 抹无香味润肤霜。

罕见副作用

简体中文
-
灼伤、严重变红(例如在毛囊附近)和胀痛: 这些反应极少出现, 这是由使用 对肤色而言过高的光照强度造成的。 如果三天内这些反应仍未消失,建议您咨 询医生。 请等到皮肤痊愈后再进行第二次照射,并确保使用较低的光照强度。
-
皮肤变色: 这种现象极少发生。 皮肤变色通常表现为比周围区域更暗(色素沉 着)或更亮(色素减退)。 这是由使用对肤色而言过高的光照强度造成的。 如 果两周内皮肤变色反应仍未消失,建议您咨询医生。 请等到皮肤变色反应消失 且恢复正常肤色后再对变色部位进行照射。
-
皮肤感染现象极少出现,但可能会在(小)伤口、皮肤烧伤、皮肤过敏后发 生。
-
表皮发热(边缘清晰的褐色区域,通常表现为较深的肤色且不会伴随皮肤干燥 现象): 这种现象极少发生。 如果一周内表皮发热现象仍未消失,建议您咨询 医生。 请等到皮肤痊愈后再进行第二次照射,并确保使用较低的光照强度。
-
起泡(在皮肤表面看起来像一些小泡泡): 这种现象极少发生。 如果一个月内 起泡现象仍未消失或皮肤发生感染,建议您咨询医生。 请等到皮肤痊愈后再进 行第二次照射,并确保使用较低的光照强度。
-
结疤: 通常是皮肤烧伤的副效应,可能至少需要一个月才能痊愈。
-
毛囊炎(毛囊周围肿胀并伴有化脓现象): 这种现象极少发生,通常是由于细 菌渗入受损的皮肤而导致的。 如果发生这种现象,建议您咨询医生,因为毛囊 炎治疗可能需要使用抗生素软膏。
-
极度疼痛: 如果您在未剃毛的皮肤上或在对肤色而言过高的光照强度下使用本 设备,或者在同一皮肤区域闪光多次,或者在开放性伤口、发炎、感染、纹身 或灼伤等部位使用本设备,则可能在照射期间或之后产生此反应。
37

后期护理

清洁和存放

在照射后,您可以在照射部位放心涂抹乳液、乳霜、香体液、润肤霜或化妆品。 如果您在照射后发生皮肤过敏或皮肤发红现象,应等到症状消除后再在皮肤上涂抹 美容制品。 如果在皮肤上涂抹美容制品后发生皮肤过敏现象,应用水进行冲洗。
注意: 即便遵守了所有的指示,您仍有可能发生皮肤反应。 在这种情况下,请停 止使用本设备,并联系您所在国家/地区的客户服务中心。
1 使用后应关闭设备,拔下电源插头,并使其冷却。 2 取下附件。
38
简体中文
3 用少许水将设备随附的软布沾湿,然后用它清洁以下部件:
-
透光窗口
-
附件的外表面
-
附件内部的反射镜 4 让所有部件彻底晾干。 5 将本设备存放在无尘、干燥的地方,温度应介于 -25°C 和 60°C 之间。

保修和支持

如需信息或支持,请访问 www.philips.com/support 或阅读国际保修卡。
回收
-
弃置本产品时,请不要将其与一般生活垃圾放在一起,应将其交给政府指定的 回收中心。 这样做将有利于环保。

技术规格

SC1995、SC1993
额定电压 100 V-240 V
额定频率 50 Hz-60 Hz
额定输入 36 瓦
防电击保护 II 类
保护等级 IP 30 (EN 60529)
使用条件 温度:+15°C 至 35°C
存放环境温度 -25°C 至 70°C
存放环境湿度
运行压力 700 hPa 至 1060 hPa
海拔 最大 3000 米
发射波长 530 nm 至 1400 nm
光学曝光 2.5 - 5.0 J/cm²,取决于所选设置
最大光能 20 J
脉冲持续时间
重复时间 1-3.5 s,取决于所选设置
光学均匀性
小于 90%(无冷凝)
<1.5 ms
照射区域的平均光学照射量偏差最大为 +/- 20%

故障处理方法

本章归纳了使用本设备时最常见的一些问题。 如果您无法根据以下信息解决问 题,请访问 www.philips.com/support 查阅常见问题列表,或联系您所在国家/地 区的客户服务中心。
问题 可能的原因 解决方法
设备/适配器在使用过程中发热这是正常的。 不需要采取措施。
简体中文
39
当我将附件放在皮肤上 时,“准备闪光”指示灯不 亮,但是冷却风扇仍在运转。
“准备闪光”指示灯呈绿色, 但当我按下闪光按钮时,设备 并没有闪光。
我无法增加或减小光强设 置/所有光强指示灯交替闪烁
我在照射期间觉得皮肤比平时 敏感/我在使用设备时感到不 适。
过热保护已被激活。 在过热保护被激活后,风扇仍在工作。 请勿
设备需要重置。 若要重置设备,先关闭设备,然后再重新打
设备需要重置。 若要重置设备,先关闭设备,然后再重新打
附件或滤光玻璃脏污。 小心地清洁附件。设备散发出一种奇怪的味道。
您没有很好地剃除待照射部位的 毛发。 这些毛发可能发生灼烧 而发出气味。
您使用的光强设置过高。 检查您选择的光强设置是否合适。 必要时选
您没有去除待照射部位的毛发。 在使用 Lumea 前对皮肤进行预处理。
透光窗口的紫外线滤光器损坏。 如果紫外线滤光器损坏,请勿再使用本设
所脱毛的部位不适合使用本设备。切勿在以下部位使用本设备:面部、内阴
本设备不适用于您的肤色。 如果您是 V 或 VI 皮肤类型(棕黑色或更深
关闭设备,而是让它冷却约 15 分钟,然后 再继续使用。
开。
开。
在使用 Lumea 前对皮肤进行预处理。
择较低的设置。
备。 请与您所在国家/地区的飞利浦客户服 务中心、飞利浦经销商或飞利浦服务中心联 系。
唇、肛门、乳头、乳晕、嘴唇、鼻孔和耳朵 内侧、眼睛周围和眉毛附近的区域。 男士不 得在面部、颈部或阴囊上使用本设备。
色的皮肤),请勿使用本设备。
照射后皮肤反应的持续时间比 平时要长。
您使用了对您而言过高的光强设置。下一次应选择低一些的光强。请参阅“使用
飞利浦 Lumea”一章中“选择合适的光 强”一节。
мȞġĈҴˀΙĀǩ؆Ӎߒʔ
ˌɫǩ؆
ĈҴˀΙ
(Pb)
(Hg)
(Cd)
ԣᲱ
(Cr (VI) )
Ġ⅑ԓ᧠
(PBB)
Ġ⅑ȕ᧠⓭
(PBDE)
ҒԜ،
O O X O O O
ʓƋៅ
X X X X X X
ϔ಴
O O O O O O
O O O X O O
ǕȪϜ֪֙5,6Āܪǭৠ뺯
OȪФ˽ĈҴˀΙć˽ˌɫǨĈߴΙࠒնġĀߒʔߴć)$6ܪǭĀՄʔđŘĪ뺯
XȪФ˽ĈҴˀΙψɺć˽ˌɫĀԚĂߴΙࠒնġĀߒʔɸŜ)$6ܪǭĀՄʔđ뺯
ݨŔӍȺԪ
মઐɫ
ЫӅ௚۸ݗї*%
*%ᇉᄳ
Ӆ௚ń٪৪௹ડԎܿຆ઴చ
ྜހń6&
ر׫׌࿦ń9
ر׫௘ń+]
ر׫ൿೊ׌ń$
ഷӅ಴௽ń౬ࡲӅ௚Ы฼
Ӆֽńྨ࿭৪
٪৪௹IJᇓݗij๫ራႹཏ܈භ
ഌݞ൫ࣥρ౹ൊހ$Ը
ಊݗܨڟ༄ಧཐ
40
简体中文
问题 可能的原因 解决方法
对照射的效果不满意。
我的身体附件没有集成式玻 璃/滤光器/窗口。
您使用了对于您而言过低的光强
下一次请选择较高的设置。
设置。
您没有在与之前照射过的部位邻
您必须在相互靠近的部位发出闪光。
近的部位发出闪光。
本设备对于您的毛发颜色没有效果。如果您是淡金色、金色或红色毛发,照射不
会有效果。
使用本产品的频率不足。 若要成功地去除所有毛发,我们建议您遵循
推荐的照射方案。 您可以缩短两次照射的间 隔时间,但照射频率不应超过每两周一次。
您对 IPL 照射的反应偏慢。 此设备应至少连续使用 6 个月,因为在此期
间仍然可以抑制毛发再生。
这是正常的。 此身体附件不含玻璃/滤光器/窗口。
-
该表格中所显示的“有害物质”在产品正常使用情况下不会对人身和环境产生 任何伤害。
-
该表格中所显示的“有害物质”及其存在的部件向消费者和回收处理从业者提 供相关物质的存在信息,有助于产品废弃时的妥善处理。
保留备用
发行日期: 15/3/2018
© 2018 Koninklijke Philips N.V. All rights reserved. Specications are subject to change without notice. Trademarks are the property of Koninklijke Philips N.V. (Royal Philips) or their respective owners.
www.philips.com
4222.100.4207.3
Loading...