ENGLISH 6
DEUTSCH 25
FRANÇAIS 46
ITALIANO 66
NEDERLANDS 86
SC1982, SC1981
6
ENGLISH
Introduction
Congratulations on your purchase and welcome to Philips!
To benet fully from the support that Philips offers,
register your product at www.philips.com/lumea.
Intended use
This appliance is intended for the removal of unwanted
hair. It is able to deliver long-term reduction in the number
of hairs that regrow after treatment. You can use Philips
Lumea Comfort to remove unwanted body hair on all
areas below the cheekbones, including the face (upper
lip, chin and cheeks). This appliance has been specically
designed and optimised for use by women, but can be used
by men as well. It is designed for use by one person only.
Safety features
Integrated safety system
Philips Lumea Comfort has an integrated safety system
that protects the eyes. This system prevents unintentional
ashing without skin contact.
Skin colour sensor
Philips Lumea Comfort has a skin colour sensor that
prevents treatment if your skin colour is too dark.
The light exit window is recessed in the treatment surface.
This prevents direct contact between your skin and the
light exit window.
Benets
Intense Pulsed Light (IPL) technology for home use
Philips Lumea Comfort uses a light-based technology called
‘Intense Pulsed Light’ (IPL). IPL is one of the most effective
methods to remove unwanted body hair. It produces longlasting results because it reduces hair regrowth signicantly.
ENGLISH7
No replacement parts needed, no hidden costs
Philips Lumea Comfort is equipped with a highperformance lamp which does not require replacement.
This lamp can generate over 100,000 ashes. This enables
you to continuously maintain results for more than
5 years*, while saving money on expensive replacement
lamps.
*Based on average usage scenario and recommended
treatment regime for one user.
Working principle
- The appliance works by heating up the hair and root
beneath the skin. The melanin in the hair and hair root
absorbs the released light pulses. The darker the colour
of the hair, the more light can be absorbed. This process
stimulates the hair to go into the resting phase.
- In between treatments, hair sheds naturally and regrowth
is inhibited. Hairs can take one or two weeks to shed.
- Optimal hair removal cannot be obtained with a single
session, since only hairs in the growing phase are
susceptible to treatment with light. During a treatment,
hairs on the treated area are usually in different stages
of the hair growth cycle. To effectively treat all hairs you
have to repeat the treatment once every two weeks for
the rst two months.
ENGLISH8
Product overview (Fig. 4)
1 On/off/intensity button
2 Intensity lights
3 READY/skin colour warning light
4 Appliance socket
5 Skin contact surface with integrated safety system
6 Light exit window with integrated UV lter
7 Skin colour sensor
8 Flash button
9 Adapter
10 Small plug
Important safety information
Read this user manual carefully before you use the
appliance and save it for future reference.
Danger
- Keep the appliance and the adapter dry.
- Do not use the appliance in wet surroundings
(e.g. near a lled bath or swimming pool or in a
running shower).
- If the appliance is broken, do not touch any inner
part to avoid electric shock.
- Never insert any objects into the appliance.
Warning
- This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, unless they have been given
supervision or instruction concerning use of the
appliance by a person responsible for their safety.
- Children should be supervised to ensure that they
do not play with the appliance.
ENGLISH9
- The appliance is not intended for children under
the age of 15 years. Teenagers aged between
15 and 18 years can use the appliance with the
consent and/or assistance of their parents or
the persons who have parental authority over
them. Adults from 19 years and older can use the
appliance freely.
- Only use the adapter supplied.
- Do not use the appliance or the adapter if it is
damaged.
- The adapter contains a transformer. Do not cut off the adapter to replace it with another plug,
as this causes a hazardous situation.
- If the adapter is damaged, always have it replaced with
one of the original type in order to avoid a hazard.
- Do not use the appliance if the glass of the light
exit window is broken.
To prevent damage
- Make sure that nothing obstructs the air ow
through the ventilation slots.
- Never subject the appliance to heavy shocks and
do not shake or drop it.
- If you take the appliance from a very cold
environment to a very warm environment or vice
versa, wait approximately 3 hours before you use it.
- Store the appliance in its original box so that it
does not become dusty.
- Do not expose the appliance to temperatures
lower than 10°C or higher than 35°C during use.
- To prevent damage, do not expose the appliance
to direct sunlight or UV light for several hours.
- Do not ash against any other surface than the
skin. This can cause severe damage to the light exit
window or the skin colour sensor. Only ash when
the appliance is in contact with the skin.
ENGLISH10
Caution
- Never leave the appliance unattended when it is
switched on. Always switch off the appliance after use.
- Always return the appliance to a service centre
authorised by Philips for examination or repair.
Repair by unqualied people could cause an
extremely hazardous situation for the user.
- Use this appliance only at intensity levels suitable
for your skin colour (see the table in chapter
‘Preparing for use’, section ‘Skin colour and
light intensity’). Use at higher levels than those
recommended can increase the risk of skin
reactions and side effects.
- Do not use the appliance if any of the conditions
mentioned in chapter ‘Contraindications,
precautions and warnings’, section
‘Contraindications’ apply to you.
- This appliance is only intended for removing
unwanted body hair from areas below the
cheekbones. Do not use it for any other purpose.
Electromagnetic elds (EMF)
This Philips appliance complies with all applicable standards
and regulations regarding exposure to electromagnetic elds.
Contraindications, precautions and warnings
Contraindications
Philips Lumea Comfort is not designed for everyone.
Please read the sections below before use.
Do not use the appliance:
- If you are pregnant or nursing.
- If your skin was exposed to strong sunlight or articial
tanning during the past 2 weeks.
- If you have a naturally brownish black or darker skin. As a
safety precaution, the built-in skin colour sensor prevents
emission of ashes if your skin is too dark.
- Near or around the eyes.
ENGLISH 11
- On a tattoo or permanent makeup in the treatment area.
- On dark spots, such as large freckles, birthmarks, moles
or warts in the treatment area.
- If you have eczema, psoriasis, lesions, open wounds or
active infections in the treatment area.
- If you have a history of collagen disorder, including
kelodial scar formation or poor wound healing.
- If you have a known sensitivity to light or take
medication that makes your skin more sensitive to
light. Medicines known to have this effect include
non-steroidal anti-inammatory agents, (e.g., aspirins,
ibuprofens, acetaminophen), tetracyclines, phenothiazines,
thiazide, diuretics, sulfonylurates, sulfonamides, DTIC,
uorouracil, vinblastine and griseofulvin.
- If you are or were recently treated with Alpha-Hydroxi Acids
(AHAs), Beta-Hydroxi Acids (BHAs), Retin-A®, Accutane®
(isotretinoin), topical retinoids, azelaic acid or steroids.
- If you have abnormal skin conditions due to diabetes or
another systemic or metabolic disease.
- If you have a history of herpes outbreaks in the
treatment area, unless you have consulted your doctor
and received preventive treatment.
- If you have a disease that causes light sensitivity, such as
porphyria, polymorphic light eruption, lupus, solar urticaria, etc.
- If you suffer from epilepsy with ashlight sensitivity.
- If you have a history of skin cancer or potential
malignancies in the treatment area.
- If you have received radiation therapy or chemotherapy
within the past 3 months.
- If you have an implant, such as a pacemaker or insulin
pump, in the treatment area.
- Do not use the appliance on nipples, areolas, labia minora,
vagina, anus and the inside of the nostrils and ears.
- Men must not use it on the face or on the scrotum.
When to consult your doctor
If you take prescribed medication or receive regular
medical monitoring because of a certain condition, consult
your doctor before you use Philips Lumea Comfort. You
should also consult your doctor if you are not sure if the
appliance is suitable for you.
ENGLISH12
Precautions
To avoid adverse effects:
- Do not treat the same area of skin more than once
during a session.
- Always shave the treatment area before treatment and make
sure that the skin in the treatment area is clean and dry.
- Do not clean the skin with ammable liquids, such as
alcohol or acetone, before you use the appliance
Warning about sun exposure and tanning
Sun exposure or articial tanning before
treatment
- Avoid sun exposure or exposure to tanning equipment
for 2 weeks before treatment. Tanned skin contains a lot
of pigment. If you use Philips Lumea Comfort on tanned
skin, this increases the risk of adverse side effects and
skin reactions.
Sun exposure or articial tanning after treatment
- After treatment, wait 48 hours before you expose your
skin to the sun or to articial tanning. Protect the skin
with a sunscreen with SPF30 or higher during the entire
hair-removal period and for at least 2 weeks after the
last treatment. If you used an articial tanning lotion to
get a tan, wait until this articial tan has disappeared
before you start the next treatment.
Possible side effects
If you use Philips Lumea Comfort according to the
instructions, the risk of serious side effects is small. Read the
sections below to learn more about the effects that may occur.
ENGLISH 13
Common side effects
- Your skin may show slight redness and/or may tingle
or feel warm. This reaction is absolutely harmless and
disappears quickly.
- A skin reaction similar to sunburn may occur on the
treated area for a short while. If this does not disappear
within 3 days, we advise you to consult a doctor.
- Dry skin and itching may occur due to shaving or a
combination of shaving and light treatment. This is
harmless and disappears within a few days. You can cool
the area with an ice pack or a wet facecloth. If dryness
persists, you can apply a non-scented moisturiser to the
skin 24 hours after the treatment.
Rare side effects
- Burns, excessive redness and swelling occur rarely and
are usually the result of using an intensity level that is
too high for your skin colour. If these reactions do not
disappear within 3 days, we advise you to consult a
doctor. Postpone the next treatment until the skin has
healed completely and use a lower intensity level.
- Skin discolouration occurs very rarely.
Skin discolouration manifests itself as either a darker or
lighter patch than the surrounding area. This may happen
if you use an intensity level that is too high for your skin
colour. If the discolouration does not disappear within
2 weeks, we advise you to consult a doctor.
Do not treat discoloured areas until the discolouration
has disappeared.
- Skin infection and inammation occur very rarely.
These reactions may occur when you use the appliance
on shaving wounds or cuts, on already existing wounds
or on ingrown hairs.
- Excessive pain may occur during or after treatment
if you use the appliance on unshaved skin, if you use
the appliance at an intensity level that is too high for
your skin colour, if you ash the same area more than
once, and if you use the appliance on open wounds,
inammations, infections, tattoos, burns, etc. See chapter
‘Contraindications, precautions and warnings’ for more
information.
ENGLISH14
Preparing for use
Preparing treatment areas
1 Before each treatment, shave the areas you intend to
treat as long as hairs continue to grow back.
Note: Do not use depilatory creams instead of shaving.
If you remove the hairs by the root with another depilation
method (e.g. waxing or an epilator), you can start treatment
immediately.
2 Make sure that your skin is dry, clean and free from
deodorants, creams, lotions or perfumes.
3 Check the light exit window and the skin colour
sensor for hairs, dust and bres. If necessary,
clean the light exit window and the skin colour
sensor with a dry, soft dry lint-free cloth.
Note: When the hairs no longer grow back, you can stop
shaving.
Skin colour and light intensity
Philips Lumea Comfort has ve different intensity levels.
Check the table below for the intensity level that suits
your skin and hair colour. ‘x’ means that the appliance is
not suitable for you. If your skin is too dark, the skin colour
sensor prevents the emission of ashes.
ENGLISH 15
Skin colour /
Body hair
colour
Black4/54/53/41/2/3xx
Dark brown4/54/53/41/2/3xx
Brown4/54/53/41/2/3xx
Dark blond /
light brown
White/grey/
red/light
blond
WhiteBeigeLight
brown
4/54/53/41/2/3xx
xxxxxx
Performing a skin test
Before your rst treatment, perform a skin test to establish
the appropriate intensity level for each body part.
1 Insert the small plug into the appliance socket and
insert the adapter into a wall socket.
2 Press the on/off/intensity button. The light of
intensity level 1 goes on and the fan inside the
appliance starts.
Mid
brown
Dark
brown
Brownish
black and
darker
3 Place the skin contact surface on the skin. Press the
ash button to release one ash at intensity level 1.
ENGLISH16
4 Move the appliance to another area and release a
ash at level 2. Continue to increase the intensity by
one level before releasing each next ash. Do not
release more than one ash in the same spot. Do not
increase the intensity beyond the maximum intensity
for your skin colour (see section ‘Skin colour and
light intensity’ in this chapter).
5 As soon as you experience any discomfort, reduce
the intensity level to the highest level at which there
was no discomfort.
6 Stop testing. Wait for 24 hours and then check your
skin for any reactions. If you see no skin reactions,
you can use the intensity level last used at your next
treatment of this body part.
Note: If your skin shows a reaction, wait for the reaction to
disappear. Then treat the body part at the intensity level below
the one that produced a reaction, wait for 24 hours and check
for skin reactions again.
7 Perform steps 1 to 5 for each body part you intend
to treat.
Using the appliance
Always perform a skin test (see chapter ‘Preparing for
use’) before you start using the appliance according to the
instructions below.
1 Insert the small plug into the appliance socket and
insert the adapter into a wall socket.
2 Press the on/off/intensity button. The light of
intensity level 1 goes on and the fan inside the
appliance starts.
ENGLISH 17
3 After about 1 second, the READY/skin colour
warning light comes on. This shows that the appliance
is ready to release a ash.
4 Press the on/off/intensity button one or more
times to choose the intensity level suitable for the
treatment area and your skin colour.
5 Make sure that the treatment area is clean,
dry and properly shaved. Place the skin contact
surface on the skin. When the skin contact surface is
in full contact with the skin, the READY/skin colour
warning light starts blinking slowly.
6 Press the ash button. The skin colour sensor checks
the colour of your skin. If the skin colour allows safe
treatment, the READY/skin colour warning light goes
off. The appliance delivers a ash to the skin and
makes a soft popping sound.
Note: If the appliance releases no ash and the READY/skin
colour warning light blinks rapidly, your skin colour is too dark
for safe treatment. If you have recently tanned skin, wait for
2 weeks (see chapter ‘Contraindications, precautions and
warnings’, section ‘Warning about sun exposure and tanning’).
ENGLISH18
7 The appliance immediately recharges for the next ash.
Depending on the intensity level selected, the READY/
skin colour warning light comes on after a few seconds.
This indicates that the appliance is ready for the next
ash. Choose one of the ash delivery methods and
continue to treat the areas you want to treat.
Note: If the treatment becomes painful at any point in time,
reduce the intensity level until the treatment is comfortable again.
If you notice skin reactions stronger than slight redness, stop the
treatment immediately and read chapter ‘Possible side effects’.
Flash delivery methods
Slide & Flash
- Keep the ash button pressed. The appliance releases
one ash after another as long as the skin contact
surface is in full contact with the skin. After each ash,
slide the appliance to the next area. Continue to press
the skin contact surface onto the skin. This Slide & Flash
mode is especially convenient for treating larger areas
like the legs.
Step & Flash
- Let go of the ash button after each ash. For the next
ash, place the appliance on the area right next to the
area just treated. Make sure that the skin contact surface
is fully pressed onto the skin. This Step & Flash mode
guarantees a precise treatment of e.g. the knees or
ankles .
Note: Do not treat the same area twice during a treatment.
If you treat an area more than once, this increases the risk of
adverse effects.
Note: To avoid untreated areas, always make sure that there
is some overlap with the previously treated area when you
slide the appliance over the skin.The effective light only comes
out of the light exit window. Make sure that the ashes are
emitted close to each other.
ENGLISH 19
How to achieve optimal results
First two months
- It is normal that hairs are still visible after the rst few
treatments (see chapter ‘Introduction’, section ‘Working
principle’ for more information).
- To remove all hairs successfully and prevent the hair
follicle from becoming active again, the treatments have
to be repeated once every two weeks for the rst two
months. Your skin should be smooth by then.
Please read section ‘Maintenance phase’ to nd out how
you can keep these results.
Maintenance phase
- To ensure that your skin stays smooth, we advise you
to repeat the treatment every 4 to 8 weeks. The time
between treatments may vary based on your individual
hair regrowth and also across different body areas.
If too many hairs grow back between treatments,
simply shorten the treatment interval again, but do not
treat any area more often than once every two weeks.
When you use the appliance more frequently than
recommended, you do not increase the effectiveness but
you do increase the risk of skin reactions.
After use
- Press and hold the on/off/intensity button to switch off
the appliance. Pull the adapter out of the wall socket.
- Clean the skin contact surface (see chapter ‘Cleaning and
maintenance’).
- Store the appliance in a safe and dry place in its original box.
- Do not apply any perfumed cosmetics to treated
skin immediately after treatment.
- Do not use deodorant immediately after treatment
of the underarms. Wait until any skin redness has
disappeared.
- See chapter ‘Contraindications, precautions and
warnings’, section ‘Warning about sun exposure and
articial tanning’ for information on sun exposure and
articial tanning.
ENGLISH20
Cleaning and maintenance
To ensure optimal hair removal results, clean the appliance
after each use.
Never clean the appliance or any of its parts under the tap.
Never use scouring pads, abrasive cleaning agents or
aggressive liquids such as petrol or acetone to clean the
skin contact surface.
1 Switch off the appliance and unplug it.
2 If necessary, clean the outside of the appliance with a
soft cleaning cloth.
3 Moisten a soft lint-free cloth with a few drops of
water and clean the skin contact surface and the light
exit window.
Environment
- Do not throw away the appliance with the normal
household waste at the end of its life, but hand it in at an
ofcial collection point for recycling. By doing this,
you help to preserve the environment.
Charging time/Power sourceContinuous operation
Time needed to treat lower leg11 minutes
Safety during operationIntegrated safety system to prevent
Package size180 x 180 x 100mm
Product weight200g
AdapterModel: KSA24A1200150HU
- rated100-240V; 50-60Hz; 0.5A
Package size180 x 180 x 100mm
Operating conditions
Temperature+10°C to +35°C
Relative humidity30% to 75% rH
Atmospheric pressure700 to 1060hPa
unintentional ashing. Skin colour sensor to
prevent treatment if skin colour is too dark.
Storage and transport conditions
Temperature-40°C to +70°C
Relative humidity10% to 90% rH
Atmospheric pressure500 to 1060hPa
ENGLISH22
Labelling
These symbols may appear on the appliance.
SymbolDescription
This symbol indicates that this appliance is double insulated (Class II).
This symbol means: Do not throw away with the normal
household waste. For further instructions, see chapter
‘Environment’.
This symbol means: Conforms to EC Directives. CE stands
for ‘Conformité Européenne’.
This symbol means: Read the user manual before you start
using the appliance.
This is the CSA mark for the USA and Canada.
Troubleshooting
This chapter summarises the most common problems you could
encounter with the appliance. If you are unable to solve the
problem with the information below, visit
www.philips.com/support for a list of frequently asked
questions or contact the Consumer Care Centre in your country.
ProblemPossible cause Solution
I have pressed
the on/off/intensity button, but
the appliance
does not switch
on.
The appliance
does not emit
a ash when I
press the ash
button.
You have not
plugged in
the appliance
properly.
Your skin
colour is not
suitable for
treatment
with this
appliance.
The READY/
skin colour
warning light
continues
to light up
steadily.
The READY/
skin colour
warning
light and the
intensity lights
are all on.
Make sure that you insert the small plug into
the appliance socket properly. Check if you
have inserted the adapter into a live wall
socket properly.
The READY/skin colour warning light blinks
rapidly. This indicates that the skin colour
sensor measured a skin colour that is too
dark for safe treatment. You can try the
appliance on a different area where the skin
is lighter. If your dark skin colour is due to
recent sunbathing or tanning, wait for
2 weeks and then try again. If the dark skin
colour is your natural colour, please check
the table in chapter ‘Preparing for use’,
section ‘Skin colour and light intensity’ to see
if the appliance is suitable for you at all.
Make sure that the skin contact surface is
in full contact with the skin. When it is, the
READY/skin colour warning light starts blinking slowly and you can press the ash button
to release a ash.
The appliance has a system error. Switch
off the appliance, unplug it and then try to
switch it on again. If the problem persists,
visit www.philips.com/support or contact the
Philips Consumer Care Centre.
ENGLISH 23
I experience
unacceptable
skin discomfort
when I use the
appliance.
You did not
shave the
treatment
areas.
Shave the treatment areas before you use
the appliance. If shaving causes skin irritation,
trim hairs as shor t as possible and use the
appliance at a comfortable setting.
ENGLISH24
ProblemPossible cause Solution
Your skin
was recently
exposed to
the sun or
to tanning
equipment.
You have
used an
intensity level
that is too
high for you.
You must not use the appliance on recently
tanned skin. Avoid exposure to the sun or
to tanning equipment for 2 weeks before
treatment.
Reduce the intensity to a level that is comfortable for you.
DEUTSCH
Einführung
Herzlichen Glückwunsch zu Ihrem Kauf und willkommen
bei Philips! Um die Unterstützung von Philips optimal
nutzen zu können, registrieren Sie Ihr Produkt bitte unter
www.philips.com/lumea.
Verwendungszweck
Dieses Gerät ist zum Entfernen von unerwünschtem Haar
vorgesehen. Es kann die Anzahl der nach der Behandlung
nachwachsenden Haare langfristig reduzieren.
Mit Philips Lumea Comfort können Sie unerwünschte
Haare an allen Körperpartien unterhalb der
Wangenknochen entfernen, einschließlich des Gesichts
(Oberlippe, Kinn und Wangen).
Dieses Gerät wurde speziell für Frauen entwickelt und
optimiert, kann jedoch ebenso von Männern verwendet
werden. Es sollte nur von einer Person benutzt werden.
Philips Lumea Comfort verfügt über ein integrier tes
Sicherheitssystem, das die Augen schützt. Dieses System
verhindert unbeabsichtigte Lichtimpulse, wenn kein
Hautkontakt besteht.
Sensor für Hautfarbe
Philips Lumea Comfort verfügt über einen Sensor für
die Hautfarbe, der keine Behandlung zulässt, wenn Ihr
Hautton zu dunkel ist. Das Lichtaustrittsfenster ist in der
Behandlungsäche versenkt. Dadurch wird der direkte
Kontakt zwischen Ihrer Haut und dem Lichtaustrittsfenster
verhindert.
Vorteile
25
IPL-Technologie (“Intense Pulsed Light”) für die
Verwendung zu Hause
Philips Lumea Comfort arbeitet mit einer lichtbasier ten
Technologie namens “Intense Pulsed Light” (IPL). IPL ist
eine der wirksamsten Methoden zur Entfernung von
unerwünschtem Körperhaar und sorgt für dauerhafte
Ergebnisse, da das Haarwachstum deutlich verringert wird.
DEUTSCH26
Keine Ersatzteile erforderlich, keine versteckten
Kosten
Philips Lumea Comfort ist mit einer Hochleistungslampe
ausgestattet, die nicht ausgetauscht werden muss. Diese
Lampe kann über 100.000 Lichtimpulse erzeugen. Damit
erzielen Sie mehr als 5 Jahre* lang gute Ergebnisse und
sparen gleichzeitig Geld für teure Ersatzlampen.
*Bei normalem Gebrauch und empfohlener Behandlung für
einen Benutzer.
Funktionsprinzip
- Zum Entfernen von Haaren erhitzt das Gerät das
Haar und die Wurzel unter der Haut. Das Melanin im
Haar und in der Haarwurzel absorbiert die vom Gerät
produzierten Lichtimpulse. Je dunkler das Haar, desto
mehr Licht kann aufgenommen werden. Dieser Vorgang
regt das Haar an, in die Ruhephase überzugehen.
- Zwischen den Behandlungen fallen die Haare aus, und
das Nachwachsen neuer Haare wird verhindert. Es kann
bis zu zwei Wochen dauern, bis die Haare ausfallen.
- Eine optimale Haarentfernung kann nicht durch eine
einzige Behandlung erzielt werden, da nur Haare in der
Wachstumsphase auf die Lichtbehandlung reagieren
und sich die Haare im behandelten Körperbereich
normalerweise in verschiedenen Wachstumsphasen
benden. Zur effektiven Behandlung aller Haare sollten
Sie die Behandlung in den ersten zwei Monaten alle zwei
Wochen wiederholen.
DEUTSCH 27
Produktübersicht (Abb. 4)
1 Ein-/Aus-/Intensitätstaste
2 Intensitätsanzeigen
3 READY-/Hauttonwarnanzeige
4 Buchse für Gerätestecker
5 Hautkontaktäche mit integriertem Sicherheitssystem
6 Lichtaustrittsfenster mit integriertem UV-Filter
7 Sensor für Hautfarbe
8 Blitztaste
9 Adapter
10 Gerätestecker
Wichtige Sicherheitshinweise
Lesen Sie diese Bedienungsanleitung vor dem
Gebrauch des Geräts aufmerksam durch, und
bewahren Sie sie für eine spätere Verwendung auf.
Gefahr
- Gerät und Adapter dürfen nicht nass werden.
- Verwenden Sie das Gerät nicht in feuchter
Umgebung (z. B. in der Nähe einer gefüllten
Badewanne, eines Schwimmbeckens oder einer
laufenden Dusche).
- Berühren Sie keine inneren Komponenten, wenn
das Gerät beschädigt ist, um einen Stromschlag zu
vermeiden.
- Führen Sie keine Objekte in das Gerät ein.
Warnhinweis
- Dieses Gerät ist für Personen (einschl. Kinder) mit
eingeschränkten physischen, sensorischen oder
psychischen Fähigkeiten nur dann geeignet, wenn
eine angemessene Aufsicht oder ausführliche
Anleitung zur Benutzung des Geräts durch eine
verantwortliche Person sichergestellt ist.
- Achten Sie darauf, dass Kinder nicht mit dem
Gerät spielen.
DEUTSCH28
- Das Gerät ist nicht für Kinder unter 15 Jahren
geeignet. Teenager zwischen 15 und 18 Jahren
sollten es nur unter Aufsicht /Anleitung ihrer
Eltern oder Erziehungsberechtigten nutzen.
- Verwenden Sie ausschließlich den mitgelieferten
Adapter.
- Verwenden Sie das Gerät oder den Adapter nicht,
wenn Beschädigungen daran erkennbar sind.
- Der Adapter enthält einen Transformator. Ersetzen
Sie den Adapter keinesfalls durch einen anderen
Stecker, da dies möglicherweise den Benutzer
gefährden kann.
- Wenn der Adapter defekt oder beschädigt ist, darf
er nur durch ein Original-Ersatzteil ausgetauscht
werden, um Gefährdungen zu vermeiden.
- Verwenden Sie das Gerät nicht, wenn das Glas des
Lichtaustrittsfensters beschädigt ist.
So vermeiden Sie Beschädigungen:
- Achten Sie darauf, dass ein ungehinderter Luftstrom
durch die Lüftungsschlitze gewährleistet ist.
- Setzen Sie das Gerät keinen schweren Stößen aus,
schütteln Sie es nicht, und lassen Sie es nicht fallen.
- Wenn das Gerät extremen
Temperaturunterschieden ausgesetzt war, warten
Sie etwa 3 Stunden, bevor Sie es benutzen.
- Bewahren Sie das Gerät im Originalkarton auf, um
es vor Staub zu schützen.
- Setzen Sie das Gerät während des Gebrauchs
keinen Temperaturen unter 10 °C oder über
35 °C aus.
- Setzen Sie das Gerät nicht über mehrere Stunden
direktem Sonnen- oder UV-Licht aus, um Schäden
zu vermeiden.
DEUTSCH 29
- Richten Sie den Lichtimpuls auf keine anderen
Oberächen als die Haut. Andernfalls können
schwere Schäden am Lichtaustrittsfenster bzw.
dem Sensor für die Hautfarbe verursacht werden.
Aktivieren Sie den Lichtimpuls nur, wenn das
Gerät in Kontakt mit der Haut ist.
Achtung
- Lassen Sie das Gerät nicht unbeaufsichtigt, solange
es eingeschaltet ist, und schalten Sie es nach
Gebrauch immer aus.
- Wenden Sie sich zur Prüfung oder zur Reparatur
des Geräts immer an ein Philips Service-Center.
Unsachgemäß ausgeführte Reparaturen gefährden
den Benutzer.
- Verwenden Sie dieses Gerät nur mit
Intensitätsstufen, die sich für Ihren Hautton
eignen (siehe Tabelle im Kapitel “Für den
Gebrauch vorbereiten”, Abschnitt “Hautton und
Lichtintensität”). Eine höhere Intensität kann zu
Hautirritationen und Nebenwirkungen führen.
- Verwenden Sie das Gerät nicht, wenn Situationen,
die im Kapitel “Gegenanzeigen, Sicherheitshinweise
und Warnungen”, Abschnitt “Gegenanzeigen”
beschrieben werden, auf Sie zutreffen.
- Das Gerät ist ausschließlich zum Entfernen
von unerwünschtem Körperhaar unterhalb der
Wangenknochen vorgesehen. Verwenden Sie es
nicht für andere Zwecke.
Elektromagnetische Felder
Dieses Philips Gerät erfüllt sämtliche Normen
und Regelungen bezüglich der Exposition in
elektromagnetischen Feldern.
DEUTSCH30
Gegenanzeigen, Sicherheitshinweise und Warnungen
Wichtige Hinweise
Philips Lumea Comfort ist nicht für jeden geeignet. Lesen Sie
die folgenden Abschnitte vor dem Gebrauch sorgfältig durch.
Verwenden Sie das Gerät nicht in folgenden Fällen:
- Wenn Sie schwanger sind oder stillen.
- Wenn Ihre Haut in den letzten zwei Wochen starkem
Sonnenlicht oder künstlichen Bräunungsmethoden
ausgesetzt war.
- Wenn Sie von Natur aus über einen braun-schwarzen
oder dunkleren Hautton verfügen.
Als Sicherheitsmaßnahme verhindert der eingebaute
Sensor für die Hautfarbe die Abgabe von Lichtimpulsen,
wenn Ihre Haut zu dunkel ist.
- In der Nähe oder um die Augen.
- Auf einer Tätowierung oder auf permanentem Make-up
im Behandlungsbereich.
- Auf dunklen Flecken, wie zum Beispiel großen
Sommersprossen, Leberecken, Muttermalen oder
Warzen im Behandlungsbereich.
- Bei Ekzemen, Schuppenechte, Läsionen,
offenen Wunden oder akuten Infektionen im
Behandlungsbereich.
- Wenn Sie unter Collagenstörungen leiden, einschließlich der
Bildung von Wulstnarben oder schlechter Wundheilung.
- Wenn Sie an Lichtempndlichkeit leiden oder
Medikamente einnehmen, die die Lichtempndlichkeit
erhöhen. Zu den bekannten Medikamenten mit dieser
Wirkung gehören nichtsteroidale Antirheumatika
(z. B. Aspirin, Ibuprofen, Paracetamol), Tetracycline,
Phenothiazine, Thiaziddiuretika, Sulfonylharnstoffe,
Sulfonamide, DTIC, Fluoruracil, Vinblastin und Griseofulvin.
- Wenn Sie derzeit oder kürzlich mit AlphaHydroxycarbonsäure (Alpha-Hydroxy Acids, AHAs),
Beta-Hydroxycarbonsäure (Beta-Hydroxy Acids, BHAs),
®
Retin-A
, Accutane® (Isotretinoin), lokal angewendeten
Retinoiden, Azelainsäure oder Steroiden behandelt wurden.
- Bei Hautkrankheiten aufgrund von Diabetes oder einer
anderen systemischen oder Stoffwechselkrankheit.
Loading...
+ 80 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.