Philips Satinelle Depiladora User Manual [en, es, it]

HP6608
A
B
C
E
F
G
J
I
H
1
2 3 4
5 6 7
1098
131211
14 15 16
191817

ENGLISH

4203.000.4314.1
2/9
Introduction
Congratulations on your purchase and welcome to
Philips! To fully benet from the support that Philips offers,
register your product at www.philips.com/welcome. With your new epilator you can remove unwanted hair
quickly, easily and effectively. It is suitable for removing hair from your legs, underarms and bikini line.
The rotating discs catch even the shortest hairs (down to
0.5mm) and pull them out by the root. The hairs that grow back are soft and thin. Epilating with this new appliance leaves your skin smooth and hair-free for several weeks. This epilator comes with the following attachments:
Hair-lifting attachment with massage element
This attachment lifts at-lying hairs, even the shortest ones. Its massage element minimises the pulling sensation
and soothes the skin after the hairs have been removed.
Opti-start cap with massage element
The opti-start cap with massage element allows you to
epilate with optimal efciency and gentleness. It ensures
ideal contact with the skin and optimal positioning of the
appliance, so that hairs are removed effectively in one
stroke. The massage element gives you a relaxing and pleasant sensation during epilation.
Sensitive area cap
The sensitive area cap has been specially designed to
epilate sensitive areas, such as your underarms and bikini line. It minimises the pulling sensation of epilation in
sensitive areas with long-lasting results.
General description (Fig. 1)
A Hair-lifting attachment with massage element B Opti-star t cap with massage element C Sensitive area cap D Epilating discs E Epilating head F On/off slide
O = off
-
I = normal speed
-
II = high speed
-
G Socket for appliance plug H Small plug I Adapter J Cleaning brush
Important
Read this user manual carefully before you use the appliance and save it for future reference.
Danger
Keep the appliance and the adapter dry.
­Do not use the appliance near or over a washbasin
-
or bath lled with water (Fig. 2).
Do not use the appliance in the bath or in the
-
shower (Fig. 3). If you use the appliance in the bathroom, do not use
-
an extension cord (Fig. 4).
Warning
Only use the appliance in combination with the
­adapter supplied. Do not use the appliance or the adapter if it is
­damaged.
If the adapter is damaged, always have it replaced
­with one of the original type in order to avoid a hazard. The adapter contains a transformer. Do not cut
-
off the adapter to replace it with another plug, as
this causes a hazardous situation. This appliance is not intended for use by persons
-
(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they
­do not play with the appliance.
Caution
Only epilate the underarms and bikini line with the
­sensitive area cap attached. This appliance is only intended for removing women’s
-
body hair on areas below the neck: underarms, bikini
area and legs. Do not use it for any other purpose.
To prevent damage and injuries, keep the running
­appliance (with or without attachment) away
from scalp hair, eyebrows, eyelashes, clothes, threads, cords, brushes etc.
Do not use the appliance on irritated skin or skin
-
with varicose veins, rashes, spots, moles (with hairs) or wounds without consulting your doctor rst.
People with a reduced immune response or people
who suffer from diabetes mellitus, haemophilia or immunodeciency should also consult their doctor rst.
Your skin may become a little red and irritated the
-
rst few times you use the epilator. This phenomenon
is absolutely normal and quickly disappears. As
you use the appliance more often, your skin gets used to epilation, skin irritation decreases and regrowth becomes thinner and softer. If the irritation has not disappeared within three days, we advise you
to consult a doctor. Do not use the epilating head or attachments if they
-
are damaged or broken, as this may cause injury.
Electromagnetic elds (EMF)
This Philips appliance complies with all standards
regarding electromagnetic elds (EMF). If handled
properly and according to the instructions in this user
manual, the appliance is safe to use based on scientic
evidence available today.
Using the appliance
Note: Clean the epilating head before rst use.
Epilation tips
When you use the appliance for the rst time, we
­advise you to try it out on an area with only light hair growth to get accustomed to the epilation process. Epilation is easier just after taking a bath or shower.
-
Make sure your skin is completely dry when you
start epilating.
Make sure your skin is clean, entirely dry and free
­from grease. Do not use any cream before you start epilating. Epilation is easier and more comfortable when the
-
hair has the optimum length of 3–4 mm. If the hairs are longer, we recommend that you shave rst and epilate the shorter regrowing hairs after 1 or 2
weeks.
When you epilate for the rst time, we advise you to
-
epilate in the evening, so that any reddening that
develops can disappear overnight. While epilating stretch your skin with your free hand.
­This lifts up the hairs and helps to minimise the pulling sensation.
For optimal performance, place the appliance on
­the skin at right angles (90°) with the on/off slide pointing in the direction in which you are going to move the appliance. Guide the appliance across the
skin against the direction of hair growth in a slow,
continuous movement without exerting any pressure.
On some areas, e.g. the underarms, hair may grow in
-
different directions. In this case, it may be helpful to
move the appliance in different directions to achieve optimal results.
To relax the skin, we advise you to apply a
­moisturising cream after epilation.
Fine hair that regrows might not grow up to the
­skin surface. The regular use of an exfoliating sponge or cream (e.g. during showering) helps to prevent ingrowing hair as the gentle scrubbing action
removes the upper skin layer and ne hair can get
through to the skin surface. When you use the hair-lifting attachment with
­massage element or the opti-start cap with massage
element, make sure that the massage element or
the comb always stays in contact with the skin. The massage element stimulates and relaxes the skin for a gentler epilation.
Connecting the appliance
1 Insert the appliance plug into the appliance (Fig. 5).
2 Insert the adapter into the wall socket.
Epilating the legs
We advise you to start epilating with the opti-start cap with massage element. The opti-start cap with massage element ensures maximum skin contact and allows you
to epilate your legs more quickly and efciently. After a
few sessions, you can use the epilating head with the hair-
lifting attachment with massage element. This attachment
ensures optimal hair lifting, relaxes the skin and minimises
the pulling sensation of epilation.
If you already have some experience with epilation, you
can simply use the epilating head without any attachment.
Only use the opti-start cap with massage element and the hair-lifting attachment with massage element on your legs.
1 Put the desired attachment (opti-start cap with
massage element or hair-lifting attachment with massage element) on the epilating head (Fig. 6).
The procedure for placing the attachments onto the appliance is the same for all attachments.
2 Select the desired speed to switch on the
appliance (Fig. 7).
Preferably use speed II. Switch to speed I for areas with little hair growth, for hard-to-reach areas and for areas where bones are located directly beneath the skin, such
as knees and ankles.
3 Stretch the skin with your free hand to make the
hairs stand upright.
4 Place the epilator perpendicularly onto the skin
with the on/off slide pointing in the direction in which you are going to move the appliance (Fig. 8).
5 Move the appliance slowly over the skin, against the
direction of hair growth.
Press the appliance lightly onto the skin.
Epilating the underarms and bikini line
Your epilator comes with a sensitive area cap that reduces the number of active epilating discs. This makes the appliance ideal for epilating the sensitive areas of the
body, such as the underarms and bikini line. The rst few times you use the appliance, these areas are particularly sensitive to pain, but after repeated use the pain sensation
diminishes.
Note: You get the best results in the most comfortable way when the hairs are not too long (approx. 4mm).
1 Thoroughly clean the area to be epilated to remove
any residues of deodorant, cream etc. Then dab the area dry.
2 Put the sensitive area cap on the epilating
head (Fig. 9).
3 Switch on the appliance.
Preferably use speed II. Switch to speed I for areas with
little hair growth and for hard-to-reach areas.
4 Stretch the skin with your free hand. When epilating
the underarms, raise your arm to stretch the skin.
5 Place the appliance perpendicularly onto your skin,
with the on/off slide pointing in the direction in which you are going to move the appliance.
6 Move the appliance slowly over the skin, against the
direction of the hair growth.
Epilate your bikini line as shown in the gure (Fig. 10).
-
Epilate your underarms as shown in the gure. Move
-
the appliance in different directions (Fig. 11).
Cleaning and maintenance
Note: Make sure the appliance is switched off and unplugged before you start to clean it.
Never use scouring pads, abrasive cleaning agents or aggressive liquids such as petrol or acetone to clean the appliance.
Never rinse the appliance or the adapter under the
-
tap (Fig. 12). Keep the appliance and the adapter dry (Fig. 13).
-
Cleaning the attachments
1 Remove any attachment (sensitive area cap,
opti-start cap with massage element, hair-lifting attachment with massage element) from the epilating head (Fig. 14).
2 Remove loose hairs from the attachment with the
cleaning brush.
3 Rinse the attachment under the tap while turning it.
4 Dry the attachment before you use or store it.
Cleaning the epilating head
4203.000.4314.1
3/9
1 Push the epilating head in the direction of the
arrows on the back of the appliance (1) and remove it (2) (Fig. 15).
2 Remove loose hairs with the cleaning
brush (Fig. 16).
3 Rinse the epilating head under the tap for 5-10
seconds while turning it (Fig. 17).
4 Shaketheepilatingheadrmly(Fig.18).
Dry the epilating head thoroughly with a tea towel.
Note: Make sure the epilating head is completely dry before you place it back onto the appliance.
Replacement
All parts of the appliance can be replaced. If you need to replace one or more of the following parts, go to your
Philips dealer or an authorised Philips service centre:
appliance itself
­epilating head
­sensitive area cap
­opti-start cap with massage element
­hair-lifting attachment with massage element
­cleaning brush
­adapter
-
Environment
Do not throw away the appliance with the normal
-
household waste at the end of its life, but hand it in at an ofcial collection point for recycling. By doing this, you help to preserve the environment (Fig. 19).
Guarantee & service
If you need service or information or if you have a problem, please visit the Philips website at
www.philips.com or contact the Philips Consumer Care
Centre in your country (you nd its phone number in the worldwide guarantee leaet). If there is no Consumer Care Centre in your country, go to your local Philips
dealer.
Troubleshooting
This chapter summarises the most common problems
you could encounter with the appliance. If you are unable to solve the problem with the information below, contact
the Consumer Care Centre in your country.
Problem Cause Solution
Poor epilating results.
You move the appliance in the wrong direction.
You place the epilating head on the skin at the wrong angle.
You used a (depilatory) cream prior to epilation.
The hairs are too short.
Move the appliance
against the direction of
hair growth, with the
on/off slide pointing in the direction in which you move the appliance.
Make sure that you
place the appliance on the skin at an angle of 90° (see chapter ‘Using the appliance’).
Make sure your skin is clean, entirely dry
and free from grease. Do not use any cream before you start epilating.
Sometimes hairs are too short to be caught. The optimal length for easy removal of the hairs is
3-4mm. The hairs that
are not caught during this session will be long enough to be removed when you epilate the next time. You can also try to catch the hairs by moving the appliance across the skin a few more times.
Problem Cause Solution
The appliance does not work.
I cannot
remove the epilating head from the appliance.
The sensitive area cap is on the epilating head when you epilate your legs.
The socket to which the appliance is connected is not live.
You try to pull it straight off.
Do not use the sensitive area cap when you
epilate your legs, as the
cap reduces the number of active epilating
discs. NB: Never use
the epilator without the sensitive area cap when you epilate your underarms or bikini line.
Make sure the socket is live. If you have
connected the epilator to the socket in a
bathroom cabinet, you
may need to switch on the bathroom light to activate the socket.
Push the epilating head in the direction of the arrows on the back of the appliance before you pull it off the appliance (see chapter ‘Cleaning and maintenance’).
Loading...