GENERAL DESCRIPTION

The SAA3008 transmitter IC is designed for infrared remote control systems. It has a capacity for 1280 commands arranged in 20 sub-system address groups of 64 commands each. The subsystem address may be selected by press-button, slider switches or be hard-wired.
Commands are transmitted in patterns which are pulse distance coded. Modulated pulse transmissions allow a narrow-band receiver to be used for improved noise rejection. The modulation frequency of the SAA3008 is 38 kHz which is1⁄12 of the oscillator frequency of 455 kHz (typical).

Features

Modulated transmission
Ceramic resonator controlled frequency
Data-word-start with reference time of unique start pattern
Supply voltage range 2 V to 6.5 V
40 mA output current capability
Very low standby current (< 4 µA at V
Up to 20 subsystem address groups; up to 1280 commands
Up to 64 commands per subsystem address; up to 1280 commands
Requires few additional components
DD
= 6 V)

PACKAGE OUTLINES

SAA3008P: 20-lead DIL; plastic (SOT146); SOT146-1; 1996 December 6. SAA3008T: 20-lead mini-pack; plastic (SO20; SOT163A); SOT163-1; 1996 December 6.
Philips Semiconductors Preliminary specification
Infrared remote control transmitter (RECS 80 low voltage)
SAA3008
Fig.2 Pinning diagram.
Fig.1 SAA3008 application example.

PINNING

1 REMO remote data output 2 SEN6N 3 SEN5N 4 SEN4N 5 SEN3N 6 SEN2N 7 SEN1N 8 SEN0N 9 ADRM address/mode control input 10 V 11 OSCI oscillator input 12 OSCO oscillator output 13 DRV0N 14 DRV1N 15 DRV2N 16 DRV3N 17 DRV4N 18 DRV5N 19 DRV6N 20 V
SS
DD
sense inputs from key matrix
ground (0 V)
drive outputs to key matrix
positive supply voltage
Philips Semiconductors Preliminary specification
Infrared remote control transmitter (RECS 80 low voltage)
FUNCTIONAL DESCRIPTION Key matrix (DRV0N -DRV6N and SEN0N-SEN6N)
The transmitter keyboard is arranged as a scanned matrix with seven driver outputs (DRV0N to DRV6N) and seven sensing inputs (SEN0N to SEN6N) as shown in Fig.1. The driver outputs are open-drain n-channel transistors which are conductive in the stand-by mode. The sensing inputs enable the generation of 56 command codes. With two external diodes connected (or triple contact), as in Fig.1, all 64 commands are addressable. The sense lines have p-channel pull-up transistors, so that they are HIGH until pulled LOW by connecting them to an output via a key depression to initiate a code transmission. The maximum allowable value of contact series resistance for keyboard switches in the ON-state is 7 k.

Address/mode input (ADRM)

Subsystem addresses are defined by connecting one or two of the key matrix driver lines (DRV0N to DRV6N) to the ADRM input. This allows up to 20 subsystem addresses to be generated for the REMO output (bits S3, S2, S1 and S0) as shown in Table 1 and Fig.3.
The transmission mode is defined by the DRV6N to ADRM connection as follows:
Mode 1 DRV6N not connected to ADRM
Mode 2 DRV6N connected to ADRM
In Mode 1 the reference time REF equals 3To, this may be used as a reference time for the decoding sequence. In Mode 2 an additional modulated pulse has been inserted into the middle of the reference time, therefore, these pulses are now separated by 1.5To. This unique start pattern START uses the detection of a beginning word (see Fig.3). When more than one connection is made to ADRM then all connections should be decoupled using diodes.
SAA3008
while the command key is pressed. A chance of the subsystem address does not start a transmission.
In a multiple keystroke sequence (Fig.6) the second word B might be transmitted with subsystem address 18 or 19 instead of the preselected subsystem address (Table 1). This is only relevant for systems decoding subsystem address 18 or 19.

Remote control signal output (REMO) The REMO output driver stage incorporates a bipolar

emitter-follower which allows a high output current in the output active (HIGH) state (Fig.7). The information is defined by the distance ‘t leading edges of the modulated pulses (Fig.4). The distance tbis a multiple of the basic unit To(Table 3) which equals 1152 periods of the oscillator frequency f (Table 3). The pulses are modulated with 6 periods of1⁄ of the oscillator frequency (38 kHz).
The format of the output data is illustrated in Figs 3 and 4. A data word starts with the reference time and toggle bit T0 and is followed by the definition bits for the subsystem address S3, S2, S1 and S0 (bit S3 is transmitted only for subsystem addresses 8 to 20). The selected command key is defined by bits F, E, D, C, B and A as shown in Table 2. The toggle bit T0 acts as an indication for the decoder whether the next instruction should be considered as a new command or not. The codes for the subsystem address and the selected key are given in Table 3.
’ between the
b
osc
12
The ADRM input has switched pull-up and pull-down loads. In the stand-by mode only pull-down load is active and ADRM input is held LOW (this condition is independent of the ADRM circuit configuration and minimizes power loss in the standby mode). When a key is pressed the transmitter becomes active pull-down is switched OFF, pull-up is switched ON) and the driver line signals are sensed for the subsystem address coding.
The subsystem address is sensed only within the first scan cycle, whereas the command code is sensed in every scan. The transmitted subsystem address remains unchanged if the subsystem address selection is changed
Philips Semiconductors Preliminary specification
Infrared remote control transmitter (RECS 80 low voltage)
(b) Transmission with start-pattern and subsystem address 8 to 20.
Where:
Reference time start pattern T0 toggle bit S3, S2, S1, S0 subsystem address A to F command bits
t
W word length
binary values determined by pulse spacing
SAA3008
Fig.3 Data format of remote control signal (REMO).
Fig.4 Waveform for one pulse period at REMO output; for timing values see Table 3.

Oscillator (OSCI, OSCO) The external components for the oscillator circuit are connected to OSCI and OSCO. The oscillator operates with a

ceramic resonator in the frequency range 350 kHz to 500 kHz, as defined by the resonator. When operating at a supply voltage of below 3 V a 270 kHz resistor should be connected in parallel with the resonator.
Philips Semiconductors Preliminary specification
Infrared remote control transmitter
SAA3008
(RECS 80 low voltage)
Table 1 Definition of subsystem addresses
address driver line(s) subsystem address number connected to ADRM S3 S2 S1 S0
1 no connection 11 1 2 DRV0N 00 0 3 DRV1N 00 1 4 DRV2N 01 0 5 DRV3N 01 1 6 DRV4N 10 0 7 DRV5N 10 1 8 DRV0N and DRV2N 0 0 0 0
9 DRV0N and DRV3N 1 0 0 0 10 DRV0N and DRV4N 0 1 0 0 11 DRV0N and DRV5N 1 1 0 0 12 DRV1N and DRV2N 0 0 0 1 13 DRV1N and DRV3N 1 0 0 1 14 DRV1N and DRV4N 0 1 0 1 15 DRV1N and DRV5N 1 1 0 1 16 DRV2N and DRV3N 1 0 1 0 17 DRV2N and DRV4N 0 1 1 0 18 DRV2N and DRV5N 1 1 1 0 19 DRV3N and DRV4N 0 1 1 1 20 DRV3N and DRV5N 1 1 1 1