Philips Semiconductors Linear Products Product specification
NE/SA5234
Matched quad high-performance low-voltage
operational amplifier
August 31, 1994
160
ABSOLUTE MAXIMUM RATINGS
SYMBOL PARAMETER RATING UNITS
V
CC
Single supply voltage 7 V
V
ESD
ESD protection voltage at any pin
5
human body model
robot model
2000
200
V
V
V
S
Dual supply voltage +3.5 V
V
DP
Voltage at any device pin
1
VS + 0.5 V
I
DP
Current into any device pin
1
+ 50 mA
V
IN
Differential input voltage
2
0.5 V
V
CM
Common-mode input voltage (positive) VCC + 0.5 V
V
CM
Common-mode input voltage (negative) VEE - 0.5 V
P
D
Power dissipation
3
500 mW
T
J
Operating junction temperature
3
+150
°C
V
SC
Supply voltage allowing indefinite output short circuit to either rail
3,4
7 V
T
STG
Storage temperature range -65 to +150
°C
T
SOLD
Lead soldering temperature (10sec max) +300
°C
θ
JA
Thermal impedance
14 pin Plastic DIP 80
°C/W
14 pin Plastic SO 115
°C/W
NOTES:
1. Each pin is protected by ESD diodes. The voltage at any pin is limited by the ESD diodes.
2. The differential input of each amplifier is limited by two internal diodes, connected in parallel and opposite to each other . For more differential input range, use differential resistors in series with the input pins.
3. The maximum operating junction temperature is +150
°C. At elevated temperatures, devices must be derated according to the package
thermal resistance and device mounting conditions. Derates above +25
°C: F package at 6.7mW/°C; N package at 9.5mW/°C; D package
at 6.25mW/
°C.
4. Simultaneous short circuits of two or more amplifiers to the positive or negative rail can exceed the power dissipation ratings and cause
eventual destruction of the device.
5. Guaranteed by design.
RECOMMENDED OPERATING CONDITIONS
SYMBOL PARAMETER RATING UNITS
V
CC
Single supply voltage +2 to +5.5 V
V
S
Dual supply voltage +1 to +2.75 V
V
CM
Common-mode input voltage (positive) VCC + 0.25 V
V
CM
Common-mode input voltage (negative) VEE - 0.25 V
T
A
Temperature
NE 0 to +70
°C
SA -40 to +85
°C