Philips Respironics InnoSpire Mini Instructions Manual

InnoSpire Mini
InnoSpire Mini
Compressor nebulizer system
CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician
or licensed healthcare professional.
Système de nébuliseur à compresseur
MISE EN GARDE : Aux États-Unis, la loi fédérale limite la vente de ce dispositif aux
médecins ou autres professionnels de la santé dûment agréés, ou sur leur ordonnance.
PRECAUCIÓN: Las leyes federales (EE.UU.) limitan la venta de este dispositivo a un
médico o profesional sanitario con licencia o bajo sus órdenes.
1114277_InnoSpireMini_Compressor_IFU_13AA.indd 1 12/19/13 10:21 PM
2 3
Index
English EN 4 Français FR 16 Español ES 28 EMC data sheets (EN) 40
1114277_InnoSpireMini_Compressor_IFU_13AA.indd 2-3 12/19/13 10:21 PM
4 5
ENGLISH
Read these instructions before using this compressor. If you do not understand any portion of these instructions, contact your healthcare provider or call Philips Respironics Customer Service at 1-800-345-6443 or 1-724-387-4000.
Intended use statement
The Innospire Mini is intended to provide a source of compressed air for medical purposes. It is to be used with a pneumatic (jet) nebulizer to produce aerosol particles of medication for respiratory therapy for both children and adults.
Unpacking your InnoSpire Mini system
When you unpack your InnoSpire Mini from its shipping case:
Carefully examine the contents against items listed and for damage. Make sure you have all the
content items listed and that they are not damaged.
Save these Instructions for use for reference.
Report anything missing or damaged to Philips Respironics.
Note: Retain carton and packing materials for storing the unit or for product returns.
Read these warnings and cautions before using your InnoSpire Mini
Warnings and cautions
It is recommended to have a backup device (e.g. MDI) for respiratory delivery in case a situation arises when your nebulizer cannot be used (e.g. during a power outage or if your compressor and/or battery becomes inoperable for any reason).
DANGER –To reduce the risk of electrocution:
Always unplug this compressor immediately after using.
Do not place or store product where it can fall or be pulled into a tub or sink.
Do not place in or drop into water or other liquid.
Do not reach for product that has fallen into water. Unplug immediately.
Electromagnetic information: Portable and RF communication devices such as cellular phones, pagers, etc. can interrupt operation of electrical medical equipment. For this reason, your compressor must be placed far enough away from these devices to prevent interference. This device meets the IEC60601-1-2 Standard for Electromagnetic Compatibility (EMC). EMC data sheets are available upon request from Philips Respironics Customer Service at 1-800-345-6443 or 1-724-387-4000. The CE mark on the product denotes compliance with all applicable EU
InnoSpire Mini
InnoSpire Mini compressor
(back view)
ON/OFF switch
Filter holder
Air outlet
Compressor AC power plug-in
12V DC (car) adapter
Rechargeable lithium
ion battery pack
AC power adapter (100-240v)
Air filters – 4 pcs.
Neb holder (front view)
InnoSpire Mini
SideStream Plus nebulizer
Carrying caseTubing
Filter cap
1114277_InnoSpireMini_Compressor_IFU_13AA.indd 4-5 12/19/13 10:21 PM
6 7
ENGLISH
Do not use the compressor on a bed/blanket to avoid overheating.
In case of accidental spillage of water or any liquid, dry the compressor immediately, and then
allow any residual moisture to dry completely before operating.
Save these instructions
How to use your InnoSpire Mini
1
Check the nebulizer and compressor for damage. Read the nebulizer instructions prior to use.
2
Place your InnoSpire Mini compressor on a firm, flat surface near an electrical outlet (if using
AC power) and where you can be seated comfortably during your treatment. Do not hold the compressor in hand during treatment.
3
To use the compressor with the AC power adapter, connect the AC power adapter into
the power plug-in on the back of the compressor. Then connect the other end into the electrical outlet.
4
Alternatively the unit can be used with the rechargeable battery pack or 12V DC (car)
adapter. Read the section relating to the rechargeable batter y pack carefully. Use only with 12V vehicle electrical system.
5
Do not operate the unit without the filter or with a clogged (dirty) or wet filter. Operating
the unit with a dirty filter can impair proper operation and cause damage that is not covered by the warranty.
6
Wash your hands before beginning your treatment.
7
Assemble your nebulizer and add your prescribed medicine following your prescription and
the separate nebulizer instructions.
8
Connect one end of the tubing to the bottom of the nebulizer and the other end of the
tubing to the air outlet on the compressor.
9
Turn the power on/off switch to begin your treatment. A green light appears indicating that
the unit is on.
10
When your treatment is complete, turn the power on/off switch and unplug the unit if using
AC power or 12V DC (car) adapter.
11
Clean the nebulizer according to its instructions.
Directives. Note that the Notified Body number does not apply to the RoHS (restriction of the use of certain hazardous substances in electrical and electronic equipment) Directive.
WARNING – To reduce the risk of burns, electrocution, fire or injury to persons:
Do not operate compressor while it is in carrying case.
A compressor should never be left unattended when plugged in.
Adult supervision is necessary when this product is used by, on, or near children or physically
challenged individuals.
Use this product only for its intended use as described in this manual. Failure to do so
may compromise performance. Do not use nebulizers or accessories not recommended by the manufacturer.
Never operate this product if it has a damaged cord or plug, if it is not working properly, if it
has been dropped or damaged, or dropped into water.
Do not use with an extension cord.
Do not use this device in-line in a ventilator circuit.
Keep the power cord away from heated surfaces.
This unit has been designed for intermittent use: 30 minutes ON / 30 minutes OFF. Failure
to operate appropriately may lead to device damage.
To avoid the risk of possible electrical shock, the compressor must be operated using the
specified power sources.
Do not remove the compressor housing or disassemble unit. There are no serviceable par ts.
Never use while sleeping or drowsy.
Do not use while operating a vehicle.
InnoSpire Mini and all its parts must be disposed of according to the local regulations in force.
Do not stack the compressor with other equipment.
Small parts can be inhaled, swallowed or dangerous. Cable, due to its length, may result in
provoking strangulation or asphyxiation. Do not leave the device alone with a small child or physically challenged individual or individual with learning difficulties.
People who require assistance might underestimate the risks involved, such as strangulation,
therefore they should be supervised.
Device should not be used around flammable substances, in an oxygen rich environment, or in
the presence of a flammable anaesthetic mixture with air, oxygen or nitrous oxide.
Use the product in a clean environment, one that is free from dirt, dust, pet hair etc.
1114277_InnoSpireMini_Compressor_IFU_13AA.indd 6-7 12/19/13 10:21 PM
8 9
ENGLISH
InnoSpire Mini
4
To remove the rechargeable lithium ion battery, lift the
front of the compressor off the battery while pressing the release button on the rechargeable lithium ion batter y.
InnoSpire Mini
3
Fit the front end of the compressor down until it engages
with a “click” into the front end of the rechargeable lithium ion battery.
1
Shift the contact cover on the bottom of the Innospire
Mini compressor so the battery contacts are uncovered.
Battery contacts on compressor
InnoSpire Mini
2
To attach the battery, align the back end of the Innospire
Mini compressor into the back end of the rechargeable lithium ion battery.
How to attach and detach the rechargeable lithium ion battery
AC power adapter plug-in
Indicator light
Battery contacts
Release button
Rechargeable lithium ion battery
InnoSpire Mini
Read these instructions before using this battery The battery will not charge when it is connected to the compressor
Read these warnings and cautions before using this battery
Warnings and cautions
Use only with Philips Respironics Innospire Mini compressor and power adapter.
Do not immerse in water.
Do not use battery if accidentally dropped in water.
Do not touch with wet or moist hands.
Do not dispose of in fire.
Do not expose to direct sunlight, chemicals, high temperatures or humidity.
Do not allow metal objects to touch metal parts of the battery as it may result in a short circuit.
Do not disassemble.
Do not tr y to operate the compressor while charging the batter y as the compressor will
not operate.
1114277_InnoSpireMini_Compressor_IFU_13AA.indd 8-9 12/19/13 10:21 PM
10 11
ENGLISH
CAUTION: Clean the device, according to instructions, between patients when used on multiple patients.
Care and cleaning of your InnoSpire Mini
CAUTION: To reduce risk of electric shock, DO NOT DISASSEMBLE and never submerge or place under running water.
1
Unplug the compressor before cleaning.
2
Use a damp cloth to wipe down the outside of the compressor as required. Do not use
abrasive cleaners.
3
Check the filter periodically and
replace the filter when dir ty.
4
To change the filter:
Use a coin to unscrew the filter holder (Note: Turn clockwise to unscrew).
Pull out filter and replace with new filter.
Screw filter holder back on by turning counter clockwise.
5
After each cleaning, check that the unit is working properly by verifying that air still
comes out of the nozzle when the unit is turned to the “on” position and that the unit’s noise level has not increased. (Increased noise indicates improper filter positioning.)
6
The compressor is oil-free. Do not lubricate.
InnoSpire Mini compressor (back view)
In
noSpi r e
M i n
i
Indicator light
Battery indicator lights
1
The battery indicator light will turn orange when the
battery is being charged.
2
The battery indicator light will turn green when the
battery is fully charged while still connected to charging source.
3
The battery indicator light will blink orange when the
battery is almost exhausted/drained.
4
The light is off under the following conditions:
– when the battery has charge and is not connected to a charging source – when battery is fully discharged – when battery enters a fault condition
Charging the battery
1
Charge the battery pack fully prior to first use.
2
Connect the AC or 12V DC car adapter to the power adapter plug-in
on the front side of the battery.
3
Plug the other end of the AC or DC car adapter into the wall outlet
or 12V DC car outlet.
4
The battery indicator light will turn orange.
5
Charge the battery until the battery indicator turns green. It may take up to 6 hours to
fully charge the batter y.
6
Unplug the power adapter from both the batter y power plug-in and the wall outlet or
12V DC car outlet.
Storing the battery
1
Store the batter y fully charged in a cool dry place.
2
Every 1-2 months, fully charge the battery to maintain maximum battery capacity.
3
It may take up to 5 charge/discharge cycles to return the battery to maximum capacity after
prolonged storage.
1114277_InnoSpireMini_Compressor_IFU_13AA.indd 10-11 12/19/13 10:21 PM
12 13
ENGLISH
The thermal protector has been activated due to: a. The device operating outside the conditions outlined in this
manual.
b. The device has been operating near heat sources or in hot
environments.
Allow the compressor to cool down for a minimum of 40 minutes. Wait until the red light turns off before turning the compressor on again.
Troubleshooting
Problems Solutions
Compressor overheats. The compressor has an internal thermal protector to prevent the device from overheating. If the internal temperature reaches the preset level, the unit will automatically shut down, and the ON/OFF button light will turn red.
The compressor does not operate.
Check all power sources to the compressor. Push the ON/OFF button again.
The device is noisy.
Should the device still not operate properly after checking the unit as indicated above, contact Philips Respironics Customer Service at 1-800-345-6443 or 1-724-387-4000.
Check that the filter cover is correctly positioned.
Medication does not nebulize properly.
Check for proper connection of the tubing adapter. Make sure the nebulizer is not empty. Clean the nebulizer as described in the manual. Replace the nebulizer. Check the intake filter and replace it if it is dirty.
Make sure battery contacts cover is removed Check the assembly of the battery pack to compressor Compressor is disabled when battery is charging. Remove
charger from battery to operate the compressor. Ensure battery pack has adequate charge. Recharge battery. Short circuit protection may have been activated. This fault
condition can be re-set by charging the battery pack.
The compressor does not operate when connected to battery.
Specifications
Power supply See adapter rating label Weight 0.93 lbs. Size 4.5” x 3.5” x 2.1” (114.3 mm x 88.9 mm x 53.3 mm) Noise level 50+/_ 4dBA Average flow rate 3.4 LPM @12.7 psi Maximum pressure 30 psi Maximum flow rate ~ 8 LPM Mode of operation Intermittent use 30 min ON / 30 min OFF
Class II device (double safety insulation). Type BF device (device with specific protection against electrical hazards).
Certification
Electric safety standards EN 60601-1 Electromagnetic compatibility according to EN 60601-1-2
Storage conditions
Temperature MIN -4° F MAX 140°F (MIN -20° C MAX +60° C) Humidity MIN 10% RH –MAX 95% RH Atmospheric pressure Performance may vary depending on altitude above sea level, barometric pressure and temperature
Operating conditions
Temperature MIN 41° F MAX 104°F (MIN +5° C MAX +40°C) Humidity MIN 10% RH –MAX 95% RH Atmospheric pressure Performance may vary depending on altitude above sea level, barometric pressure and temperature
Expected service life
Compressor 3 years from date of purchase Battery 6 months from date of purchase
Replacement parts and accessories
Filter 1109488 AC power/battery charger 1109441 12V DC (car) adapter 1109455 Rechargeable lithium ion battery 1110726
1114277_InnoSpireMini_Compressor_IFU_13AA.indd 12-13 12/19/13 10:21 PM