4 Ft.
FC=2188
ø=8 in.
CDM-R111
35000 MBCP
10
º
3000K Spot
FC=972 ø=13 in.
FC=547 ø=17 in.
FC=350 ø=21 in.
FC=243
ø=25 in.
FC=179
ø=29 in.
FC=137
ø=34 in.
FC=88
ø=42 in.
6 Ft.
8 Ft.
10 Ft.
12 Ft.
14 Ft.
16 Ft.
20 Ft.
112 mm (4.4") MAX
95 mm (3.74") MAX
MasterColor®Ceramic Metal Halide 38Watt R111 Reflector Spot Lamp
with FadeBlock™UV Filtering
Ordering Information
Ordering Code CDM-R 11135W/830 10DG ANSI Designation M130/O Product Number 13554- 1 Description MasterColor Ceramic
Package Quantity 6
Physical Characteristics
Base/NeckTransition 150ºC (302ºF) Neck/Reflector 200ºC (392ºF) TopAnti-glare Cap 350ºC (662ºF)
Metal Halide
Beam spread at 50% Maximum Beam Candlepower—0º primary angle FC=Footcandles at mounting height ø=Beam diameter at mounting height
Operating Characteristics (Photometric)
Approx.Initial Lumens Approx.Mean Lumens RatedAverage Life, Hours Correlated ColorTemperature (CCT) 3000 K CIE ChromaticityApproximate x-.433,y-.402 Color Rendering Index (CRI) 81 Efficacy (lpw) 37 MBCP (Maximum Beam Candlepower) 35,000 BeamAngle (at 50% of MBCP) 10º
1
2
3
1400 900 11,000
Operating Position
Universal
Note: Operate lamp only on approved thermally
protected electronic ballast.
Philips Lighting Company 200 Franklin Square Drive P.O.Box 6800 Somerset, NJ 08875-6800 1-800-555-0050
Division of Philips Electronics North America Corporation
A
pdated 6/07 TDS-135541
U
www.philips.com
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050
A Division of Philips Electronics Ltd.
MasterColor®Ceramic Metal Halide 38 Watt R111 Reflector Spot Lamp with FadeBlock
Electrical Data (
Subject to change without notice)
LampWatts (Nominal) . . . . . . . . . . . . . . . . . .. . . . . . . . . . . 38
Lamp OperatingVoltage (rms) (Nominal)4. . . . . . . . . . . . . 88
Initial LampVoltage Range (rms)5. . . . . . . . . . . . . . . . . . .. . 80-100
Lamp Operating Current (Amps) (rms) (Nominal) . . . . . 0.53
Lamp Current Crest Factor (Maximum) . . . .. .. . . . . . . . 1.8
Warm-upTime to 80% of Output . . . . . . . . . . . . . . . . .. . 3 Minutes
Re-strikeTime for Hot Lamp. . . . . . . . . . . .. .. . . . . . . . . . 4-8 Minutes
BallastType (Electronic Only). .. .. . . . . . . . . . . . . . . . . . .. ANSI M130/O
Ballast Open CircuitVoltage (Minimum). .. . . . . . . . . . . . . 198
Pulse Peak Volts . .. . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . 3000 Min.,4000 Max.
PulseWidth @ 90% Peak . .. .. . . . . . . . . . . . . . . . . . .. . . . 2 Micro Second Minimum
Pulse Repetition Rate (Minimum)
6
. . . . . . . . . . . . . . . . . . .. 1 per Half Cycle
Minimum OperatingTemperature . . . .. . . . . . . . . . . . . . . . -30ºC (-22ºF)
) Measured at 100 hrs.life. Approximate lumen values listed are for vertical operation of the lamp.
1
) Approximate lumen output at 40% of lamp rated average life.
2
3) Rated average life is the life obtained,on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based onsurvival of at least 50% of the lamps andallows for individual lamps or groups of lamps to vary considerably fromthe average.
4) Measured at rated lamp watts on a linear reactor.LPW does not include ballast losses.
5) Measured with thelamp operating at rated watts.
) Option-Pulse Width @ 90% Peak, 1 micro second minimum with 2 pulses per half cycle.
6
Warnings,Cautions and Operating Instructions
“WARNING:These lamps can cause serious skin burn and eye inflammation
R
from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used.Certain lamps that willautomatically extinguish when the outer envelope is broken or punctured are commerciallyavailable.” This lamp complies with FDA radiation performance standard 21 CFR subchapterJ. (USA:21CFR 1040.30 Canada:SOR/DORS/80-381)
If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if the envelope is struck.
WARNING: The arc-tube of metal halide lamps are designed to operate under high
pressure and at temperatures up to 1000º C and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment.If such a rupture were to happen,THERE
IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE,BURNS AND FIRE. These lamps are designed to retain all the glass particles should an arc tube rupture occur.The following operating instructions are recommended to minimize these occurrences.
RELAMPFIXTURESAT OR BEFORETHE END OF RATED LIFE.Allowing lamps to operate untiltheyfailis not advised and may increase the possibility of inner arc tube rupture.
This lamp contains an arc tube with a filling gas containing less than 10 nCi of Kr-85 and is distributed by Philips Lighting Company,a division of Philips Electronics North America Corporation, Somerset,New Jersey,08875.
CAUTION:TO REDUCETHE RISK OF PERSONAL INJURY, PROPERTY DAMAGE,
BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURE THE FOLLOWING
LAMP OPERATING INSTRUCTIONS
MUST BE FOLLOWED:
LAMP OPERATING INSTRUCTIONS:
1. RELAMP FIXTURESAT OR BEFORETHE END OF RATED LIFE.Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.
2. Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards.
3. Use only auxiliary equipment meeting Philips and/orANSI standards.Use within voltage limits recommended by ballast manufacturer.
A.Operate lamp only within specified limits of operation. B. For total supply load refer to ballast manufacturers electrical data.
C.Operate 39W PAR-20 and PAR-30L lamps only on thermally
protected ballast.
D.OperateCDM-R111lamp only on approved thermally protected
electronic ballast.
4. Periodically inspect the outer envelope.Replace any lamps that show scratches, cracks or damage.
5. If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass.
6. Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.
7. Time should be allowed for lamps to stabilize in color when turned on for the first time. This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock,and color appearance may vary between individual lamps.
8.Lamps may require up to10 minutes(4–8 minutes for CDM-R111) to re-light if there is a power interruption.
9. Take care in handling and disposing of lamps. If an arc tube is broken,avoid skin contact with any of the contents or fragments.
10.For proper installation and removal, lamp should be handled by the sides of the reflector
and not by the aluminum front anti-glare cap.