Philips P-5781-B User Manual

Ceramalux®High Pressure Sodium Non-Cycling Lamps featuring ALTO Lamp Technology
Ideal for street and roadway lighting, parking lots and garages, warehouses and manufacturing facilities where lower maintenance costs are desired
HIGH PRESSURE SODIUM
®
† This lamp is better for the environment because of
its reduced mercury content.All Philips ALTO lamps give you end-of-life options which can simplify and reduce your lamp disposal costs depending on your state and local regulations.
Reduce maintenance costs
Philips Ceramalux®High Pressure Sodium Non-Cycling Lamps
are a better value than standard high pressure sodium lamps, with longer life and reduced maintenance cost.
Rated average life of 30,000 hours
• 65% lamp survival at 30,000 hours rated average life
• 80% lamp survival at 24,000 hours rated average life
• 25% longer life than standard HPS lamps
Reduces maintenance costs
• Lamp goes out—stays out
• Eliminates unnecessary service trips to replace lamp
• More resistant to outages caused by vibration and line voltage fluctuations
*
®
Environmentally responsible
• Passes the US EPAs TCLP for non hazardous waste
• Sustainable lighting solution: Up to 90% less mercury than standard Philips Ceramalux®High Pressure Sodium Lamps and lead free
Direct replacement for standard HPS lamps
• Offers higher lumen output for most wattages
• 90% lumen maintenance
• Operates on HPS ballasts of similar wattages
(*,†,See back page for footnotes)
0
60
8
0
70
90
100
%
Percent – Approx. Survival
0 20 40 60 80 100 (0) (6,000) (12,000) (18,000) (24,000) (30,000)
0 20 40 60 80 100 (0) (6,000) (12,000) (18,000) (24,000) (30,000)
Percent of Rated Average Life
(Lamp Operating Hours)
Percent of Rated Average Life
(Lamp Operating Hours)
0
60
80
70
90
100
%
Percent – Approx. Survival
0 20 40 60 80 100 (0) (6,000) (12,000) (18,000) (24,000) (30,000)
0 20 40 60 80 100 (0) (6,000) (12,000) (18,000) (24,000) (30,000)
Percent of Rated Average Life
(Lamp Operating Hours)
Percent of Rated Average Life
(Lamp Operating Hours)
Ceramalux®High Pressure Sodium Non-Cycling Lamps featuring ALTO®Lamp Technology
Ordering, Electrical and Technical Data
Product ANSI Nom. Pkg. Bulb LCL MOL Avg.Life Initial Mean Temp.
Rated Approx Approx Color
Number Ordering Code Code Watts Bulb Base Qty. Finish (In.) (In.) (Hrs.)1Lumens2Lumens3(Kelvin)
20224-2 C50S68/ALTO NC HPS S68 50 ED231⁄2 Mogul 20 Clear 5 73⁄4 30,000 4000 3600 2100 14739-7 C70S62/ALTO NC HPS S62 70 ED23 14740-5 C100S54/ALTO NC HPS S54 100 ED23 14741-3 C150S55/ALTO NC HPS S55 150 ED23 15725-5 C200S66/ALTO NC HPS S66 200 ED18 Mogul 12 Clear 5 14742-1 C250S50/ALTO NC HPS S50 250 ED18 Mogul 12 Clear 5 14743-9 C400S51/ALTO NC HPS S51 400 ED18 Mogul 12 Clear 5 15726-3 C1000S52/ALTO NC HPS S52 1000 ED25 Mogul 6 Clear 8
1) Rated average life is the life obtained, on the average, from large representative groups of lamps in laborator y tests under controlled conditions at 10 or more operating hours per start. It is based on sur vival of 65% of the lamps and allows for individual lamps or groups of lamps to var y considerably from the average.
2) Approximate lumen values listed are for ver tical or horizontal operation of lamp.
3) Approximate mean lumen output at 40% of lamp rated average life.
4) Approximate color temperature in Kelvin degrees.
1
2 Mogul 12 Clear 5 73⁄4 30,000 6300 5670 2100
1
2 Mogul 12 Clear 5 73⁄4 30,000 10,000 9000 2100
1
2 Mogul 12 Clear 5 73⁄4 30,000 16,000 14,400 2100
3
4 93⁄4 30,000 22,000 19,800 2100
3
4 93⁄4 30,000 28,500 25,650 2100
3
4 93⁄4 30,000 50,000 45,000 2100
3
4 151⁄16 30,000 130,000 117,000 2100
Above specifications subject to change without notice.
Approximate Lumen Maintenance
Ceramalux®High Pressure Sodium Non-Cycling
Approximate Survival Curve
Ceramalux®High Pressure Sodium Non-Cycling
4
Footnotes from front:
* Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start.
It is based on sur vival of 65% of the lamps and allows for individual lamps or groups of lamps to var y considerably from the average.
† The TCLP is the US EPA’sToxicity Characteristic Leaching Procedure. Check state and local regulations regarding non-hazardous waste .
Higher lumen output for 50, 100, 150, 200, and 250 watts and equivalent for 400W, and less for 1000W.
RECOMMENDEDWARNINGS, CAUTIONS,AND OPERATING INSTRUCTIONS
“WARNING:
R
lamps.The fixture wattage rating must match the wattage indicated on the outer glass bulb. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter.A par tial vacuum in the outer bulb may cause glass to fly if the glass is struck. Operating the lamp improperly may result in
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
1) If the outer glass bulb is broken, shut off power immediately and remove the lamp after it has cooled.
2) Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended
by ballast manufacturer.
A. Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers electrical data.
These lamps must be operated in fixtures designed for use with High Pressure Sodium
© 2008 Philips Lighting Company.All rights reserved. Printed in USA 2/08
P-5781-B
www.philips.com
3) Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.
4) Replace the lamp if the outer glass bulb has been scratched, cracked or damaged in any way.
5) If a lamp bulb support is used, be sure to insulate the support electrically so as to avoid possible decomposition of the bulb glass.
6) Do not use this lamp in a fixture which redirects a substantial por tion of the energy toward the arc tube and its immediate vicinity, as this may lead to ver y early lamp failure.
7) Take care in handling and disposing of lamps. If arc tube is broken, avoid skin contact with any of the contents or fragments.
8) The arc tube of this lamp contains sodium and mercury. Dispose of in accordance with federal, state and local requirements.
Philips Lighting Company 200 Franklin Square Drive P.O. Box 6800 Somerset, NJ 08875-6800 1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050
A Division of Philips Electronics Ltd.