Philips P-5562-B User Manual

hilips Protected Metal
P Halide “O” Rated Lamps
Ideal for manufacturing
acilities, retail establishments
f and warehouses
Shrouded Arc Tube for
“O” Open Fixture Rating
“O” rated for safe operation in open fixtures
Philips Protected Metal Halide“O” Rated Lamps
Protective quartz shroud provides extra level of safety
• Shrouded arc tube for "O" open fixture rating
No shut-off required
• Ideal for 24-hour a day, 7-day a week operations (relamp fixtures at or before the end of rated life)
Extended eyelet mogul base will operate in both standard and exclusionary sockets
Satisfies the 2005 NEC for use in open luminaires
* Relamp fixtures at or before end of rated average life.
† The 2005 NEC states that luminaires that use a metal halide lamp shall be provided with either a containment
barrier that encloses the lamp (historically referred to as an enclosed luminaire) or shall be provided with a means, typically a special lampholder, that will only accept ANSIType-O metal halide lamp. (Exception—this requirement will not apply to open luminaires with thick-glass parabolic reflector PAR lamps.) For more information regarding use ofType-O, S, and E metal halide systems, please refer to the NEMA white paper on this subject that is freely available at www.nema.org
Extended Eyelet Mogul (EEM) Base
(EX39 Exclusionary Mogul)
*
Philips Protected Metal Halide “O” Rated Lamps
Ordering Data
P
umber Ordering Code Watts Code Size Finish (In.) (In.) (Hrs.)
N
8119-6 MP175/BU 175 M57/O ED-28 CLEAR 8
2
8124-6 MP250/BU 250 M58/O ED-28 CLEAR 8
2 13067-4 MP360/BU/EW 360 M165/M59/O ED-37 CLEAR 11 13068-2 MP360/C/BU/EW 360 M165/M59/O ED-37 COATED 11 13332-2 MP400/BU 400 M59/O ED-37 CLEAR 11
3333-0 MP400/C/BU 400 M59/O ED-37 COATED 11
1
8118-8 MP1000/BU 1000 M47/O BT-56 CLEAR 15
2
ickel plated brass base
N
1) Rated average life is the life obtained,on the average, from large representative groups of lamps in labor atory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to var y considerably from the average. For lamps with a rated average life of 24,000 hours, life is based on sur vival of 67% of the lamps.
) Approximate lumen values listed are for ver tical operation of the lamp.
2
3) Approximate lumen output at 40% of lamp rated average life .
Above specifications subject to change without notice .
Electrical and Technical Data
RMS Lamp Operating Current (Amps) Nominal——————————— 1.5 (175W)
————————————————————————————— 2.1 (250W)
—————————————————————————————— 3.0 (360W) ————————————————————————————— 3.25 (400W)
————————————————————————————— 4.1 (1000W) Lamp Current Crest Factor (Maximum)——————————————————1.8 Warm-up to 80% Full Brightness ———————————————— 3–5 minutes Re-start Time for Hot Lamps —————————————————10–20 minutes
Protected Metal Halide Lamps, Open or Enclosed Fixtures, Base Up Operation,
15º Unless Otherwise Noted
±
Recommended Warnings, Cautions and Operating Instructions
WARNING:
ultraviolet radiation if outer envelope of the lamp is broken or punctured.Do not use where
R
people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.”This lamp complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30 Canada:SOR/DORS/80-381)
If the outer bulb is broken or punctured,turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if the envelope is struck.
WARNING:The arc-tube of metal halide lamps are designed to operate under high pressure
and at temperatures up to 1000º C and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment.If such a rupture were to happen,THERE IS A RISK OF PERSONAL
INJURY, PROPERTY DAMAGE,BURNSAND FIRE.
These lamps are designed to retain all the glass particles should an arc tube rupture occur.The following operating instructions are recommended to minimize these occurrences.
RELAMP FIXTURESAT OR BEFORETHE END OF RATED LIFE.Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.
CAUTION:TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURETHE FOLLOWING
LAMP OPERATING INSTRUCTIONS
These lamps can cause serious skin burn and eye inflammation from shortwave
MUST BE FOLLOWED:
ulb
B
ulb MOL LCL Avg.Life Initial Mean
B
5
6
1
5
5
6
1
5
1
2 7 20,000 34,200 23,940 65 4000K
1
2 20,000 31,700 20,605 68 3600K
1
2 7 20,000 38,000 26,600 65 4000K
1
2
3
.5 12,000 107,000 75,000 65 3900K
8 9
1
umens Lumens CRI CCT
L
10,000 15,000 12,000 65 3800K 10,000 22,000 16,500 62 3800K
20,000 34,500 22,425 67 3700K
Physical Characteristics
Bulb Temperature (Maximum)————————————————— 400°C (752°F)
ase Temperature (Maximum)————————————————— 210°C (410°F)
B Base —————————————————————————— EX39 Excl. Mog. Operating Position ————————————————————— Base-up ± 15° Luminaire ——————————————————————— Open or Enclosed
tandard Package Quantity —————————————————12 (175W, 250W)
S
———————————————————————— 6 (360W, 400W, 1000W)
LAMP OPERATING INSTRUCTIONS:
1.RELAMP FIXTURESAT OR BEFORETHE END OF RATED LIFE.Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.
2. Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards.
3. Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer.
A. Operate lamp only within specified limits of operation. B. For total supply load refer to ballast manufacturers electrical data.
4.Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage.
5. If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass.
6.Protect lamp base,socket and wiring against moisture,corrosive atmospheres and excessive heat.
7. Time should be allowed for lamps to stabilize in color when turned on for the first time. This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock, and color appearance may vary between individual lamps.
8. Lamps may require 10 to 20 minutes to re-light if there is a power interruption.
9. Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents or fragments.
10. Do not use this lamp:
A. In a fixture that contains a Pulse Start metal halide ballast. B. In a fixture that is specifically designed for use with Pulse Start metal halide lamps.
Operation of these lamps on Pulse Start Metal Halide systems may increase the chance of an outer bulb rupture and pieces of extremely hot glass might be discharged into the surrounding environment.If such a rupture were to happen,THERE IS A RISK OF PERSONAL INJURY,PROPERTY DAMAGE, BURNSAND FIRE.
roduct Nom. ANSI
Rated
About Metal Halide Lamp Classifications
Every metal halide lamp is classified under one of the following three American National Standards Institute (ANSI) classifications:
E-Type are to be used in only suitably rated enclosed luminaries. S-Type may be used in open luminaries, when operated in the near vertical position.This category of lamps is limited only to certain lamps in a 350 to 1000 watt range. O-Type comply with ANSI Standard C78.387 for containment test and may be used in open luminaries.
For more information on “Best Practices for Metal Halide Lighting Systems,” please visit www.nema.org and search for document number LSD 25-2000.
© 2007 Philips Lighting Company.All rights reserved. Printed in USA 06/07
P-5562-B
www.philips.com
Printed on chlorine free paper from Sappi Fine Paper mills,who are accredited with EMAS environmental certification. Sappi claims that the pulp used in the manufacture of Magno Dull paper is derived from environmentally certified forests.
Philips Lighting Company 200 Franklin Square Drive P.O. Box 6800 Somerset, NJ 08875-6800 1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050
A Division of Philips Electronics Ltd.
Loading...