Philips T8 Lamps featuring
ALTO II™Technology
Ideal for applications
requiring maximum
maintained light output
T8 COLLECTION
ALTO II™means 50%
less mercury than the
original ALTOT8 lamps
†
Extra low mercury
Philips T8 lamps are environmentally responsible.
Extended life
• Reduce maintenance costs by extending the relamping cycle
• Warranty period: 30 months
Outstanding lumen performance
• 95% lumen maintenance and reduced lamp-end blackening
Better for the environment
• Only 1.7mg of mercury withALTO II™Technology
• Reduced impact on the environment without sacrificing performance
Original 2', 3' and 4' T8 lamps featuringALTO
†
LampTechnology had 3.5mg of mercury. New 2',3'
and 4' T8 lamps featuring ALTO II
ave 1.7mg of mercury.
h
™
Technology
®
PhilipsT8 Lamps featuring ALTO II™Technology
0 10,000 20,000 30,000 40,000 50,000 0 10,000 20,000 30,000 40,000 50,000
Rated Average Life in HoursRated Average Life in Hours
BASED ON 3 HOURS PER START
4
Programmed Start BallastInstant Start Ballast
24,000
30,000
30,000
36,000
BASED ON 12 HOURS PER START
1
0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,0000 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000
100%
98%
96%
94%
92%
90%
100%
98%
96%
94%
92%
90%
Lamp Operating HoursLamp Operating Hours
Light Output (%)Light Output (%)
rdering, Electrical andTechnical Data
O
olor Nom. RatedAverage Life (hrs)
roduct Ordering Pack. Temp. Length 12-hr on 12-hr on Initial Design Lumen
P
umber Code Watts Qty. (Kelvin) (In.) Ins.Start Prog.Start Lumens
N
6787-0 F17T8/TL830/ALTO 17 25 3000 24 30,000 36,000 1400 1330 85 95%
3
*
6791-2 F17T8/TL835/ALTO 17 25 3500 24 30,000 36,000 1400 1330 85 95%
3
*
6793-8 F17T8/TL841/ALTO 17 25 4100 24 30,000 36,000 1400 1330 85 95%
3
*
14123-4 F17T8/TL850/ALTO 17 25 5000 24 30,000 36,000 1325 1260 82 95%
*
36807-6 F17T8/TL730/ALTO 17 25 3000 24 30,000 36,000 1325 1260 78 95%
*
36808-4 F17T8/TL735/ALTO 17 25 3500 24 30,000 36,000 1325 1260 78 95%
*
6812-6 F17T8/TL741/ALTO 17 25 4100 24 30,000 36,000 1325 1260 78 95%
3
*
6813-4 F25T8/TL830/ALTO 25 25 3000 36 30,000 36,000 2225 2115 85 95%
3
*
6814-2 F25T8/TL835/ALTO 25 25 3500 36 30,000 36,000 2225 2115 85 95%
3
*
6825-8 F25T8/TL841/ALTO 25 25 4100 36 30,000 36,000 2225 2115 85 95%
3
*
14124-2 F25T8/TL850/ALTO 25 25 5000 36 30,000 36,000 2150 2040 82 95%
*
36826-6 F25T8/TL730/ALTO 25 25 3000 36 30,000 36,000 2125 2020 78 95%
*
6828-2 F25T8/TL735/ALTO 25 25 3500 36 30,000 36,000 2125 2020 78 95%
3
*
6829-0 F25T8/TL741/ALTO 25 25 4100 36 30,000 36,000 2125 2020 78 95%
3
*
E
4667-8 F32T8/TL830/ALTO 32 25 3000 48 30,000 36,000 2950 2800 85 95%
2
E
24670-2 F32T8/TL835/ALTO 32 25 3500 48 30,000 36,000 2950 2800 85 95%
E
24671-0 F32T8/TL841/ALTO 32 25 4100 48 30,000 36,000 2950 2800 85 95%
E
27229-4 F32T8/TL850/ALTO 32 25 5000 48 30,000 36,000 2850 2700 82 95%
E
27252-6 F32T8/TL730 ALTO 32 25 3000 48 30,000 36,000 2800 2660 78 95%
*
E
7249-2 F32T8/TL735/ALTO 32 25 3500 48 30,000 36,000 2800 2660 78 95%
2
*
E
27248-4 F32T8/TL741/ALTO 32 25 4100 48 30,000 36,000 2800 2660 78 95%
*
E
38351-3 F32T8/TL741/ALTO 32 10 4100 48 30,000 36,000 2800 2660 78 95%
*
E
27268-2 F32T8/TL750/ALTO 32 25 5000 48 30,000 36,000 2700 2565 78 95%
*
1) Average life under engineering data with lamps turned off and restarted once every 12 operating hours.
2) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory
onditions. For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The ballast factor is a
c
multiplier applied to the designated lamp lumen output.
3) Design lumens are the approximate lamp lumen output at 40% of the lamp’s r ated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under
tandard laboratory conditions.
s
It’s anticipated that lamp will be available Quar ter 1, 2008.
*
E
Lamp meets US Federal Minimum Efficiency Standards.
This lamp is better for the environment because of its reduced mercury content. All Philips ALTO II
nd local regulations.
a
C
™
lamps give you end-of-life options which can simplify and reduce your lamp disposal costs depending on your state
1
pprox.
A
2
umens
L
3
C
RI Maint.
95% Lumen Maintenance
Philips T8 Lamps
Specifications are subject to change without notice.
© 2007 Philips Lighting Company.All rights reserved.
Printed in USA 06/07
P-5338-G
www.philips.com
Printed on chlorine free paper from Sappi Fine Paper mills, who are accredited with EMAS environmental cer tification.
Sappi claims that the pulp used in the manufacture of Magno Dull paper is derived from environmentally certified forests.
Rated Average Life
Philips T8 Lamps
4) Average life under specified test conditions with lamps turned off
and restarted no more frequently than once every 3 operating hours.
Lamp life is appreciably longer if lamps are star ted less frequently.
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.