Philips P-2055-D User Manual

hilips White SON
P Pressure Sodium Lamps
I lighting and downli ghting
®
H
igh
Incandescent-like color performance
PhilipsWhite SON®High Pressure Sodium Lamps
produce warm, incandescent-like color with exceptional
WHITE SON
®
brightness and color rendering properties
Energy efficient
• Three times the efficacy and five times the life of incandescent lamps
Excellent lumen maintenance
• Long life and reliable stable color performance
Choice of ED-17 or T-10 lamps
• ED-17 diffuse coated medium screw base lamp offers low source brightness for downlighting applications
• T-10 clear lamp with PG-12 prefocus base provides precise optical control for accent and display lighting applications
Low ultraviolet output
• Minimizes fading of materials
Rated for use in open fixtures
PhilipsWhite SON®Lamps
Ordering Data
Lamp
Product Lamp Lamp Current ANSI Initial Mean Number Ordering Code Watts Volts (Amps) Code Lumens1Lumens
Oper. Approx. Approx
31344-5 SDW-50W/LV/D 50 45 1.4 S104 2350 2000
1346-0 SDW-100W/LV/D 100 52 2.5 S105 4900 4170
3
0229-9 SDW-T50W/LV 50 45 1.4 S104AF-50 2300 2070
3
0228-1 SDW-T100W/LV 100 52 2.5 S105NZ-100 5000 4250
3
) Based on photometry of 100-hour lamps in vertical position at rated watts. Lumen output rating applies to all operating positions.
1
) Lumen output at 50% rated life.
2
) Based on survival of at least 50% of the lamps, operated under specified test.
3
) 90% sur vival at 5000 hour s.
4
Electrical and Technical Data
Lamp Current Crest Factor (Maximum) ————1.8 Warm-up to 80% Full Brightness ———3–4 minutes RestrikeTime for Hot Lamps ———— 1–2 minutes Starter Pulse Voltage—Peak ——————3500-4900 Pulse Width @ 90% Peak —0.5 Micro Sec. Minimum Pulse per Cycle (Minimum) ——————————1
Operating Characteristics
Rated Average Life, Hours.
3,4
———————10,000 Color Rendering Index (CRI)—————————85 Color Temperature ———————————2700K
Operating Position
niversal
U
Physical Characteristics
Bulb ——————————————ED-17 (SDW)
———————————————T-10 (SDW-T)
ulb Finish ———————————Diffuse (SDW)
B
——————————————— Clear (SDW-T)
Base —————————————Medium (SDW)
———————————————PG-12 (SDW-T)
Max. Overall Length (MOL) —5.438'' (xxmm) (SDW)
———————————5.875" (XXmm) (SDW-T)
Light Center Length (LCL) —3.438'' (xxmm) (SDW)
———————————3.563" (XXmm) (SDW-T)
Arc Length —————————0.X'' (7mm) (50W)
———————————— 0.XX" (9mm) (100W)
Max. Bulb Temp. ————350ºC (XXXºF) (50W T-10)
————— 400˚C (XXX˚F) (50W & 100W ED-17) ————————— 450˚C (XXX˚F) (100W T-10)
Max. Base Temp. ———————150° C (50W T-10)
—————————190° C (50W & 100W ED-17) ————————————— 180° C (100W T-10)
Standard Package Quantity ————————— 12
WHITE SON
ECOMMENDED WARNINGS, CAUTIONS AND
R
PERATING INSTRUCTIONS
O
WARNING:These lamps must be operated in fixtures
esigned for use with High Pressure Sodium lamps. The
R
d
xture wattage rating must match the wattage indicated on the
2
uter glass bulb. Do not scratch the outer bulb or subject it to
o pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if the glass is struck. Operating the lamp improperly may result in PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
1. If the outer glass bulb is broken, shut off power immediately and remove the lamp after it has cooled.
2. Use only auxiliary equipment meeting Philips and/or ANSI
tandards. Use within voltage limits recommended by
s
allast manufacturer.
b
. Operate lamp only within specified limits of operation.
A
. For total supply load refer to ballast manufacturers
B
lectrical data.
e
. Protect lamp base, socket and wiring against moisture,
3
corrosive atmospheres and excessive heat.
4. Replace the lamp if the outer glass bulb has been scratched, cracked or damaged in any way.
5. If a lamp bulb support is used, be sure to insulate the support electrically so as to avoid possible decomposition of the bulb glass.
6. Do not use this lamp in a fixture which redirects a substantial portion of the energy toward the arc tube and its immediate
icinity,as this may lead to very early lamp failure.
v
7. Take care in handling and disposing of lamps. If arc tube is broken, avoid skin contact with any of the contents or fragments.
8. The arc tube of this lamp contains sodium and mercury. Dispose of lamp in accordance with federal,state and local requirements.
®
Above specifications subject to change without notice.
© 2007 Philips Lighting Company.All rights reserved. Printed in USA 06/07
P-2055-D
www.philips.com
Printed on chlorine free paper from Sappi Fine Paper mills, who are accredited with EMAS environmental certification. Sappi claims that the pulp used in the manufacture of Magno Dull paper is derived from environmentally certified forests.
C.I.E. Color Coordinates X Y
50 Watt .462 .414
100 Watt .461 .410
Maximum Color Shift:
-250K (7500 hours)
Philips Lighting Company 200 Franklin Square Drive P.O. Box 6800 Somerset, NJ 08875-6800 1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050
A Division of Philips Electronics Ltd.
Loading...