4. Insulated liner : .040” wall, high temperature extruded thermoplastic.
5. Toggle Bolts and Screws: furnished with track unit.
6. Dead End Cap: molded thermoplastic.
7. Feed Track.
8. Plain Track.
9. Standoff Mounti ng Clip: 1/16” extruded aluminum, one screw mounting,
one screw tightening. 3/8” gap helps to compensate for ceiling irregularities.
Provides rigid support for dense loading of track.
10. Feed-in Connector Module: included with feed track.
11. Removable Hole Plug: for surface feed 3/8” or 1/2” trade size connector.
12. KO: accepts, 3/8” or 1/2” trade connector for feed.
13. Wire Cover: molded thermoplastic.
Mechanical
Track units plug together and lock securely to prevent accidental separation.
ProSpec track fixtures can be attached at any point along the track. Track units
may be field cut.
Electrical
(2) circuits. Each circuit is 120V, 60Hz, 20 AMP compatible. Each circuit has
dedicated neutral for maximum control flexibility. Track units are continuously
grounded throughout. Electrical conductors are concealed in an insulated liner
in the track. Intended for wiring to branch circuit building wire with ground, in
accordance with National and local codes.
Mounting
Surface: ProSpec track can be surface mounted either flush to a surface or
with clips
1/16” clips are provided with the track and space the track 1/16” from the
ceiling.
3/8” standoff clips can be ordered separately. These space the track 3/8” from
the ceiling, provide a rigid support and a pleasing appearance on uneven ceilings.
Stem: ProSpec track can also be suspended from horizontal surfaces or sloped
surfaces. Stems can be field cut to provide any length from a surface with a
maximum length of 3”.
A sloped surface (ceiling) adapter is available to allow the track to hang vertically with the track opening horizontal to the floor.
3/8” Standof f Clips, order separately. Recommended
2 clips per 4’, 3 clips per 8’, 4 clips per 12’ track units.
Use additional clips for more suppor t in high load
applications. Toggle bolts are included.
Not recommended for wall mounting.
26478 WH Matte White (4) per pack.
26478BK Matte Black (4) per pack.
3/8"
Direct Mounting
Toggle bolts and nylon insulators are furnished with
Track, two per 2’ and 4’ track, three per 8’ and (4) for
12’ track. Mount through existing holes in track. Top
of track sits flush to ceiling.
Recommended for wall and ceiling mounting.
Toggle Bolt
Nylon Spacer
Screw
1/16” Flush Mount C lips
Nylon coated spring steel included with track units.
Spaces track 1/16” from ceiling. Recommended 2 per
4’, 3 per 8’, and 4 per 12’ track sections. Use additional clips for more support when track is heavily
loaded. Clips may be ordered separated.
Not recommended for wall mounting.
56451WH Matte White (set of 10)
56451BK Matte BK (set of 10)
Grid Ceiling Mounting Clips
Square Edge Panels and 9/16” - 15/16” T-Bars Clip
is supplied assembled. Mounts easily onto T-Bars by
rotating clips. Use t wo per 4’ track, three per 8’ and
12” track.
6089 (9) Clips
T-Runner
Square
Edge Panel
9/16" - 15/16"
Regres sed Edge Panels
9/16” - 15/16” T-Bars
Clips os supplied assembled. Mounts easily onto
T-Bars by rotating clips. Use two per 4’ track, three
per 8’ and 12’ track.
6087 (9) Clips
T-Runner
Regressed
Edge Panel
9/16" 15/16"
6088 (9) Clips
1/4" 9/16"
Slotted Grid
Runner
5/16"
Grid Ceiling Canopy Kit (End & Floating)
For mounting the track to grid suspended ceilings.
Mounts to ceiling types shown above using clips
6087, 6088, or 6089 which are ordered separately.
Includes a special outlet box to fit onto runners.
Power can be fed to Feed Track, Live End, “L”, “T”,
“X”, and In-Line connectors. Mounts along runner or
at the intersection of runners.
4" Octagon
Outlet Box
(by others)
Surface Canopy Kit (End & Floating Feed)
Canopy can be mounted directly over the end of the
feed track, power extension, in-line, ‘L’, ‘T’, and ‘X’
connectors. Canopy also can be positioned anywhere
on the track up to 4’ from the edge of the track extrusion (floating feed, wire cover included). Power can
be fed into feed track, power extension, in-line, ‘L’,
‘T’, and ‘X’ connectors when utilizing the floating
feed option. Canopy mounts to a 4” octagonal outlet
box. Use 1/16” flush mounting clips (supplied with
track) or direct mount to ceiling or wall.
26060WH Matte White
26060BK Matte Black
4" Octagon
Outlet Box
(by others)
Square Canopy
Feed Track
or Connector
1/16" Flush
Mounting Clip
Standoff Canopy Kit (End & Floating Feed)
For use with 26478WH, BK 3/8” standoff mounting
clips (ordered separately). Canopy can be mounted
directly over the end of the feed track, power
extension, in-line ‘L’, ‘T’, and ‘X’ connectors. Canopy
also can be positioned any where on the track up
to 4’ from the edge of the track extrusion (floating
feed, wire cover included). Power can be fed into
feed track, power extension, in-line, ‘L’, ‘T’, and ‘X’
connectors when utilizing the floating feed option.
Canopy mounts to a 4” octagonal outlet box.
Mounts to a 4” Octagon outlet box. Use two per 4’
track, three per 8’ and 12’ track. When making a run
of track do not exceed 4’ between stems. Use additional stems for additional suppor t. Power is fed to
the track with the stem closest to the track feed-in
point. For power feed to Feed Track and Live End, “L”,
“T”, “X”, In-line connectors. Stem can be field cut.
Not recommended for wall mounting.
18” Stem 48” Stem
Actual length for ceiling to top of track:
17 3/8” 47 3/8”
Matte White 7584 7586
Matte Black 7683 7681
Swivel Stem Mounting Kits
Adjusts from 0° to 90°. Can be field cut. 48” stem.
7480 Matte White
7481 Mat te Black
3" or 4" Octagon
Outlet Box
(by others)
0ϒ - 90ϒ Ceiling
Slope
This end may be
field cut.
3" or 4" Octagon
Outlet Box
(by others)
This end may be
field cut.
Stem 1/4"-18
NPSM Thread
Clamp Set
Feed Track
Floating Invisible Feed
Can be mounted any where along the track at a
maximum distance of 4’ from edge of track extrusion.
Accepts conduit or cable with 3/8” or 1/2” electrical
connector (by others). Can be used with Feed Track,
Live End, “L”, “T”, “X”, and In-line connectors. Use
Track Mounting Clips to mount the track.
26082 Zinc Plated
Electrical
Fitting
(by others)
Wire Cover
Clamp Set
Feed Track
Stem Extension Kit
Mounts to any system kit to extend its length to 48”.
Replaces Dead End Cover at end of track to permit
power continuity around structural obstructions to
another track section. Not polarized. Can be fed
directly from surface or from ceiling using a 3/8”
or 1/2” electrical connector (by others).
Feed Connections for Surfac e and Stem Mo unted Pat terns
All connectors can be fed directly from above using a 3/ 8” or 1/2” electrical connector (by others).
“L” Connector
The “L” connector is pre-wired.
Not polarized.
26050WH Mat te White
26050B K Matte Black
“T ” Connector
The “T” connector is not pre-wired
or polarized. Used to make “T” pattern
with track. 12ga. copper jumper
wires supplied to make all
necessary connections.
26051WH Matte White
26051BK Mat te Black
4.18"
3.59"
5 1/4"
Extruded Aluminum Housing
3.59"
1/4"
Extrude d Aluminum Housing
See Detail A
Typ. for all Track
Connections
10 9/16"
3.59"
7 3/16"
NEUT
NEUT
See Detail A
Typ. for all
Connections
Mini-Coupler
Used to connect t wo pieces of track together
mechanically and electrically. Power cannot
be feed into the mini-coupler.
26049WH Matte White
26049BK Mat te Black
Line Joint
No Space
3 7/16"
Detail A
Use 12ga. solid copper wire for
feed connections including ground.
“X” Connector
The “X” connector is not pre-wired.
Used to make “X” pattern with track.
12ga. copper jumper wires supplied
to make all necessar y connections.
Not polarized.
7 3/16"
See Detail A
Typ. for all Track
Connections
10 9/16"
26052WH Matte White
26052BK Matte Black
In-Line Connector
Permits power feed-in between
track units in a straight run of track.
The “In-Line” connector is pre-wired.