Lytespan
®
Track Lighting System 22M W4
Page 1 of 2 Alcyon™ Micro Flood T4 12V
3
2
5 1/2 in
[138 mm]
Ordering Information
1 1/2 in
[40 mm]
1/2 in
[12 mm]
1
1 in
[24 mm]
4 1/2 in
[113 mm]
2 3/4 in
[72 mm]
4 3/4 in
[120 mm]
Catalog No. Finish Mounting Lamps
22MW4WH
22MW4BK
22MW4AL
Matte White
Matte Black
Metallic Aluminum
All Lytespan Track Systems.
Does not mount on ProSpec Track.
12V 50W Max. T4 2-pin GY6.35 base lamp. (Clear Only)
Use Philips or Sylvania lamps only, must be 1 3/4" MOL.
Transverse or C-6 filament recommended.
4
5
6
7
2 1/2 in
[63 mm]
Features
1. Transformer: Class two electronic transformer for 12v halogen lamps
2. Track At tachment Fitting: Molded polycarbonate; rotates into track
3. Brass Contact: Extends for connection to second circuit
(Advent Lytespan track only)
4. Horizontal Pivot: Wireless stem profile with infinite horizontal rotation
5. Vertical P ivot: 0-90° vertical adjustment
6. Socket: Bi-pin multipoint contact low voltage halogen socket
7. Housing: Die cast aluminum
8. Smoothing Lens: Meets UL standards for use with unshielded lamps
Finish
All Painted finishes are baked enamel.
Dimming
Use only dimmers specifically designed for use with electronic transformers.
Low voltage fixtures may produce audible sound when dimmed.
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2010 Philips Group • A0410
Accessories
Accessory Holder: None
Accessories: None
Lens: None
Louver: None
Snoot Accessory: None
Labels
UL, cUL
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:

Lytespan
®
Track Lighting System 22M W4
Page 2 of 2 Alcyon™ Micro Flood T4 12V
Lighting Data
Footcandles on wall:
La mp Information:
50W 12V T4
Lumens: 950
Rated Avg. life: 2,000 hrs.
EXAMPLE: With track located 2’ from wall and multiple units spaced
3’ on center and aimed 50˚ from horizontal, the illumination on wall 3’
from ceiling will be 25 f.c. beneath units and 24 f.c. between units.
Footcandles on Wall
Track 2 Feet From Wall Single Unit Multiple Units
0’ 1’ 2’ 3’ 4’
1’ 51 36 7 1 1
2’ 45 30 12 2 1
3’ 19 15 9 3 1
4’ 8 7 5 3 1
5’ 4 4 3 2 1
Distance From Ceiling
6’ 2 2 2 2 1
7’ 1 1 1 1 1
8’ 1 1 1 1 1
2’
Beam Center
50˚
2’
71 78 70
72 67 71
38 35 37
20 18 19
12 11 11
8 8 7
5 5 5
4 4 3
3’
58 45 58
52 44 52
25 24 25
13 13 13
8 8 8
6 5 6
4 4 4
3 3 3
56 15 56
49 24 49
20 18 20
10 10 10
6 6 6
4 4 4
3 3 3
2 2 2
4’
Track 3 Feet From Wall Single Unit Multiple Units
0’ 1’ 2’ 3’ 4’
1’ 23 21 11 3 1
2’ 23 17 11 4 1
3’ 20 16 11 5 2
4’ 12 10 8 5 2
5’ 6 5 4 3 2
Distance From Ceiling
6’ 3 3 3 2 2
7’ 2 2 2 2 1
8’ 1 1 1 1 1
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2010 Philips Group • A0410
3’
Beam Center
50˚
3’
28 33 28
31 31 31
32 30 32
22 21 23
13 13 14
9 8 9
6 6 6
4 5 4
24 23 24
25 22 25
24 23 24
17 16 17
10 10 10
7 6 7
5 5 5
4 4 4
Job Information Type:
4’ 5’
23 14 23
23 16 23
22 17 22
14 13 14
8 8 8
5 5 5
4 4 4
3 3 3