Philips Lytespan 22MW4, Lightolier Lytespan 22MW4 Specification

®
Track Lighting System  22M W4
Page 1 of 2 Alcyon™ Micro Flood T4 12V
3
2
5 1/2 in
[138 mm]
Ordering Information
1 1/2 in
[40 mm]
1/2 in
[12 mm]
1
1 in
[24 mm]
4 1/2 in
[113 mm]
2 3/4 in
[72 mm]
4 3/4 in
[120 mm]
Catalog No. Finish Mounting Lamps
22MW4WH 22MW4BK 22MW4AL
Matte White Matte Black Metallic Aluminum
All Lytespan Track Systems. Does not mount on ProSpec Track.
12V 50W Max. T4 2-pin GY6.35 base lamp. (Clear Only) Use Philips or Sylvania lamps only, must be 1 3/4" MOL. Transverse or C-6 filament recommended.
4
5
6
7
2 1/2 in
[63 mm]
Features
1.  Transformer: Class two electronic transformer for 12v halogen lamps
2.  Track At tachment Fitting: Molded polycarbonate; rotates into track
3.  Brass Contact: Extends for connection to second circuit
(Advent Lytespan track only)
4.  Horizontal Pivot: Wireless stem profile with infinite horizontal rotation
5.  Vertical P ivot: 0-90° vertical adjustment
6.  Socket: Bi-pin multipoint contact low voltage halogen socket
7.  Housing: Die cast aluminum
8.  Smoothing Lens: Meets UL standards for use with unshielded lamps
Finish
All Painted finishes are baked enamel.
Dimming
Use only dimmers specifically designed for use with electronic transformers. Low voltage fixtures may produce audible sound when dimmed.
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2010 Philips Group • A0410
Accessories
Accessory Holder:   None Accessories:  None Lens:  None Louver:  None Snoot Accessory:  None
Labels
UL, cUL
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
®
Track Lighting System  22M W4
Page 2 of 2 Alcyon™ Micro Flood T4 12V
Lighting Data
Footcandles on wall:
La mp Information:
50W 12V T4 Lumens: 950 Rated Avg. life: 2,000 hrs.
EXAMPLE:  With track located 2’ from wall and multiple units spaced  3’ on center and aimed 50˚ from horizontal, the illumination on wall 3’  from ceiling will be 25 f.c. beneath units and 24 f.c. between units.
Footcandles on Wall
  Track 2 Feet From Wall  Single Unit  Multiple  Units
0’ 1’ 2’ 3’ 4’
1’ 51 36 7 1 1 2’ 45 30 12 2 1 3’ 19 15 9 3 1 4’ 8 7 5 3 1 5’ 4 4 3 2 1
Distance From Ceiling
6’ 2 2 2 2 1 7’ 1 1 1 1 1 8’ 1 1 1 1 1
2’
Beam Center
50˚
2’
71 78 70 72 67 71 38 35 37 20 18 19 12 11 11 8 8 7 5 5 5 4 4 3
3’
58 45 58 52 44 52 25 24 25 13 13 13 8 8 8 6 5 6 4 4 4 3 3 3
56 15 56 49 24 49 20 18 20 10 10 10 6 6 6 4 4 4 3 3 3 2 2 2
4’
  Track 3 Feet From Wall  Single Unit  Multiple  Units
0’ 1’ 2’ 3’ 4’
1’ 23 21 11 3 1 2’ 23 17 11 4 1 3’ 20 16 11 5 2 4’ 12 10 8 5 2 5’ 6 5 4 3 2
Distance From Ceiling
6’ 3 3 3 2 2 7’ 2 2 2 2 1 8’ 1 1 1 1 1
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2010 Philips Group • A0410
3’
Beam Center
50˚
3’
28 33 28 31 31 31 32 30 32 22 21 23 13 13 14 9 8 9 6 6 6 4 5 4
24 23 24 25 22 25 24 23 24 17 16 17 10 10 10 7 6 7 5 5 5 4 4 4
Job Information Type:
4’ 5’
23 14 23 23 16 23 22 17 22 14 13 14 8 8 8 5 5 5 4 4 4 3 3 3