Calculite
®
HID Lensed Downlight C4T4GD-MHT4R
Page 1 of 4 4 1/2" Aperture, T4 Ceramic Metal Halide, Glasslite
Ceiling Cutout: 5 1/8” (130 mm) Dia.
For complete fixture order: Trim Kit (Glasslite) + Upper Reflector + Frame-In Kit. Sold Separately
Glasslite Trim Kit + Upper Reflector Frame-In Kit
C4T4GD +
MHT4RS (Spot Upper Reflector)
MHT4RNF (Narrow Flood Upper Reflector)
MHT4RF (Flood Upper Reflector)
C4A20BT5PGJ5E1
C4A20T4GU6 5EU
C4A20T4EU
C4A39T4GU65EU
C4A39T4E1
C4A39T4E2
C4A70 T4E1
C4A70 T4E2
Features
1. Upper Reflector: Specular faceted aluminum; select 12° Spot (MHT4RS) 25°
Narrow Flood (MHT4RNF) or 40° Flood (MHT4RF); interchangeable.
2. Glasslite Trim Kit: One piece borosilicate etched glass.
3. Lamp Holder: Unitized construction assures proper alignment of lamp to
optics for consistent optical performance.
4. Socket Housing: Galvanized steel, pre-wired with G8.5 pulse rated
socket. Snaps onto yoke for secure attachment without tools; unitized
construction assures proper alignment of lamp to optics for consistent optical
performance.
5. Frame Housing: Steel, 0.029" (22-Ga.), matte black finish. Removable cover
for top re-lamping.
6. Frame Vertical Adjustment Mechanism: Accommodates mounting to
virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT
tubing (by others). Single locking feature secures all adjustments. Alignment
holes and markings allow fixture to be pre-set prior to installation. Final
adjustment can be made from below from inside fixture.
7. Mounting Bars: Galvanized steel, 0.048" (18-ga.), pre-installed telescoping
bars extend to 30" long and lock securely into position. Built-in locking tabs
provide positive attachment to common T-bar systems. Self-centering feature
simplifies installation in 24" O.C. grid systems. Attaches to steel or wood
joists without accessories.
8. Retention Springs: Rust resistant springs secure trim for quick, tool-less
installation.
9. Ballast / Cover Assembly: Accessible from below and removable without
tools for inspection and ballast replacement .
10. Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90° C through branch circuit conductors. Allows inspection from below.
11. Optional Accessory Holder: Catalog # CAH4 Sold separately; die-formed
steel, matte black finish, slide-in installation. Accepts up to two 3 3/4" dia.
media.
Lamping (Ceramic Metal Halide)
Electronic 120V
Electronic 120V/277V
Electronic 120V/277V
Electronic 120V/277V
Electronic 120V
Electronic 277V
Electronic 120V
Electronic 277V
22W Philips MiniMasterColor
20W GE ConstantColor
20W T4.5
39W Philips MiniMasterColor
39W T4.5
39W T4.5
70W T4.5
70W T4.5
Features (continued)
12. Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high power factor, T.H.D.
<15%, thermally and transient protected, RMI/RFI complies with FCC Part 18
non-consumer limits, shut-down circuit at end of lamp life, sound rating “A”,
-5° F minimum starting temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
20W MH M156 120/277 0.21/0.10 23
39W MH M130 120/277 0.39/0.17 44
70W MH M139 120/277 0.67/0.29 78
Options and Accessories
Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Wet Locations), CSA, I.B.E.W.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609
Calculite
®
HID Lensed Downlight C4T4GD-MHT4R
Page 2 of 4 4 1/2" Aperture, T4.5 Ceramic Metal Halide, Glasslite
39W T4.5 Ceramic MH, Narrow Flood Upper Reflector, Philips, Lumen Rating = 3400 LMS., Aromat Electronic Ballast
ANGLE MEAN CP LUMENS
0 8996
5 7584
2,250
4,500
6,750
9,000
** Efficiency = 46.7% ** SC = .3 Certified Test Report No. 18678FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**
10 4322
15 2225
20 1047
60°
25 452
30 169
35 81
40 53
45 39
50 32
55 26
60 20
65 12
70 7
75 5
80 3
85 0
30°
90 0
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 7690
55 6459
65 3966
75 2612
85 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 1459 42.92 91.95
0-40 1515 44.58 95.5
0-60 1569 46.16 98.88
0-90 1587 46.68 100
40-90 71 2.1 4.5
60-90 17 0.52 1.12
90-180 0 0 0
0-180 1587 46.68 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .56 .56 .56 .56 .54 .54 .52 .52 .50 .50 .47
1 .54 .53 .52 .51 .52 .51 .50 .49 .48 .48 .46
2 .52 .51 .50 .49 .50 .48 .49 .47 .47 .46 .44
3 .51 .49 .48 .47 .48 .46 .47 .46 .46 .45 .44
4 .50 .48 .46 .45 .47 .45 .46 .44 .45 .44 .43
5 .49 .46 .45 .43 .46 .43 .45 .43 .44 .42 .42
6 .48 .45 .43 .42 .45 .42 .44 .42 .44 .42 .41
7 .46 .44 .42 .41 .44 .41 .43 .41 .43 .41 .40
8 .46 .43 .41 .40 .43 .40 .42 .40 .42 .40 .39
9 .45 .42 .41 .39 .42 .39 .42 .39 .41 .39 .39
10 .44 .41 .40 .38 .41 .38 .41 .38 .40 .38 .38
LUMINAIRE INPUT WATTS = 44
70W T4.5 Ceramic MH, Narrow Flood Upper Reflector, Philips, Lumen Rating = 6200 LMS., Aromat Electronic Ballast
ANGLE MEAN CP LUMENS
0 13659
5 11121 915
3,750
7,500
11,250
15,000
** Efficiency = 42.4% ** SC = .3 Certified Test Report No.18753FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**
10 6556
15 3509 990
20 1859
60°
25 942 441
30 400
35 177 125
40 105
45 78 62
50 65
55 55 49
60 43
65 29 30
70 20
75 11 12
80 6
85 1 2
30°
90 0
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 15547
55 13566
65 9819
75 6013
85 2289
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 2346 37.85 89.35
0-40 2471 39.87 94.11
0-60 2582 41.65 98.32
0-90 2626 42.36 100
40-90 154 2.49 5.89
60-90 44 0.71 1.68
90-180 0 0 0
0-180 2626 42.36 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .50 .50 .50 .50 .49 .49 .47 .47 .45 .45 .42
1 .49 .48 .47 .46 .47 .46 .45 .44 .44 .43 .41
2 .47 .46 .45 .44 .45 .43 .44 .42 .43 .41 .40
3 .46 .44 .43 .42 .44 .41 .43 .41 .42 .40 .39
4 .45 .43 .41 .40 .42 .40 .41 .39 .41 .39 .38
5 .44 .41 .40 .39 .41 .38 .40 .38 .40 .38 .37
6 .43 .40 .39 .37 .40 .37 .39 .37 .39 .37 .36
7 .41 .39 .37 .36 .39 .36 .38 .36 .38 .36 .35
8 .41 .38 .36 .35 .38 .35 .37 .35 .37 .35 .34
9 .40 .37 .36 .34 .37 .34 .37 .34 .36 .34 .34
10 .39 .36 .35 .34 .36 .34 .36 .34 .36 .33 .33
LUMINAIRE INPUT WATTS = 78
39W T4.5 Ceramic MH, Flood Upper Reflector, Philips, Lumen Rating = 3400 LMS. Aromat Electronic Ballast
ANGLE MEAN CP LUMENS
0 1992
5 1944 184
500
1,000
1,500
2,000
** Efficiency = 33.1% ** SC = .7 Certified Test Report No.18679FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**
10 1822
15 1660 444
20 1226
60°
25 706 322
30 315
35 139 95
40 66
45 36 31
50 30
55 26 23
60 21
65 16 16
70 11
75 7 8
80 4
85 1 2
30°
90 0
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 7192
55 6459
65 5333
75 3973
85 2101
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 949 27.94 84.42
0-40 1045 30.74 92.9
0-60 1099 32.34 97.74
0-90 1125 33.09 100
40-90 79 2.35 7.1
60-90 25 0.75 2.26
90-180 0 0 0
0-180 1125 33.09 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .39 .39 .39 .39 .37 .38 .38 .38 .35 .35 .33
1 .38 .37 .37 .36 .35 .37 .37 .35 .34 .33 .32
2 .37 .35 .34 .33 .33 .36 .35 .33 .33 .32 .30
3 .35 .34 .33 .31 .32 .35 .33 .31 .32 .30 .29
4 .34 .32 .31 .30 .30 .34 .32 .30 .31 .29 .28
5 .33 .31 .30 .28 .29 .33 .31 .28 .30 .28 .27
6 .32 .30 .28 .27 .28 .32 .30 .27 .29 .27 .26
7 .31 .29 .27 .26 .27 .31 .29 .26 .28 .26 .25
8 .30 .28 .26 .25 .26 .30 .27 .25 .27 .25 .25
9 .29 .27 .25 .24 .25 .29 .27 .24 .26 .24 .24
10 .28 .26 .24 .23 .24 .28 .26 .23 .25 .23 .23
LUMINAIRE INPUT WATTS = 44
70W T4.5 Ceramic MH, Flood Upper Reflector, Philips, Lumen Rating = 6200 LMS., Aromat Electronic Ballast
ANGLE MEAN CP LUMENS
0 3172
5 3144 303
750
1,500
2,250
3,000
** Efficiency = 32.6% ** SC = .7 Certified Test Report No.18755FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**
10 3054
15 2810 763
20 2215
60°
25 1361 618
30 668
35 279 194
40 125
45 67 57
50 55
55 47 42
60 39
65 29 29
70 20
75 13 14
80 8
85 3 3
30°
90 0
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 13385
55 11655
65 9620
75 7313
85 4282
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 1684 27.16 83.2
0-40 1878 30.29 92.79
0-60 1977 31.9 97.71
0-90 2024 32.65 100
40-90 145 2.35 7.21
60-90 46 0.75 2.29
90-180 0 0 0
0-180 2024 32.65 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .39 .39 .39 .39 .38 .38 .36 .36 .35 .35 .33
1 .37 .37 .36 .35 .36 .35 .35 .34 .33 .33 .31
2 .36 .35 .34 .33 .34 .32 .33 .32 .32 .31 .30
3 .35 .33 .32 .31 .33 .31 .32 .30 .31 .30 .29
4 .34 .32 .30 .29 .31 .29 .31 .29 .30 .29 .28
5 .32 .30 .29 .28 .30 .28 .30 .28 .29 .27 .27
6 .31 .29 .28 .27 .29 .27 .29 .27 .28 .26 .26
7 .30 .28 .27 .26 .28 .25 .27 .25 .27 .25 .25
8 .29 .27 .26 .25 .27 .24 .27 .24 .26 .24 .24
9 .28 .26 .25 .24 .26 .24 .26 .23 .25 .23 .23
10 .28 .25 .24 .23 .25 .23 .25 .23 .25 .23 .22
LUMINAIRE INPUT WATTS = 78
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609
Job Information Type:
Calculite
®
HID Lensed Downlight C4T4GD-MHT4R
Page 3 of 4 4 1/2" Aperture, PGJ5 Glasslite
22W PGJ5 Philips MiniMastercolor CMH Lamp, Narrow Flood Upper Reflector, Lumen Rating = 1650 lms, Aromat Electronic Ballast
Angle Mean CP Lumens
0 5817
5 5387 471
1500
3000
4500
6000
** Efficiency = 62.1% ** SC = .4 Certified Test Report No. 3951FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
10 3158
15 1324 435
60°
20 339
25 107 69
30 45
35 29 19
40 18
45 16 12
50 13
55 11 10
60 8
65 6 6
30°
70 3
75 2 2
80 1
85 0 0
90 0
Luminance Summary
Angle Mean CD/SQ M
45 2252
55 1858
65 1354
75 762
85 0
Zonal Lumens and Percentages
Zone Lumens %Lamp %Luminaire
0-30 975 59.15 95.24
0-40 994 60.3 97.09
0-60 1016 61.63 99.23
0-90 1024 62.11 100
40-90 29 1.81 2.91
60-90 7 0.48 0.77
90-180 0 0 0
0-180 1024 62.11 100
Coefficients of Utilization
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .74 .74 .74 .74 .72 .72 .6 9 . 69 .6 6 .66 .62
1 .72 .71 .70 .69 .70 .68 .67 .66 .6 5 .64 .61
2 .70 . 68 .67 . 66 .6 7 .65 .65 . 63 .6 4 .62 .60
3 .68 . 66 .65 . 63 .6 5 .63 .64 . 62 .6 3 .61 .59
4 .67 . 65 .63 . 61 .6 4 .61 .63 . 60 .6 2 .60 .58
5 .66 . 63 .61 . 60 .6 2 .59 .61 . 59 .61 .58 .57
6 .65 . 62 .60 . 58 .61 .58 .61 .58 .6 0 .58 .57
7 .63 . 61 .59 . 57 .6 0 .57 .59 . 57 .5 9 .56 .56
8 .63 . 59 .57 . 56 .5 9 .56 .59 . 56 .5 8 .56 .55
9 .61 . 58 .57 . 55 .5 8 .55 .58 . 55 .57 .55 .54
10 .61 . 57 .56 .5 4 .57 .54 .57 .54 .5 7 .54 .54
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
22W PGJ5 Philips MiniMastercolor CMH Lamp, Flood Upper Reflector, Lumen Rating = 1650 lms, Aromat Electronic Ballast
Angle Mean CP Lumens
0 1632
5 1513 140
400
800
1200
1600
** Efficiency = 40.0% ** SC = .5 Certified Test Report No. 3935FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
39W PGJ5 Philips MiniMastercolor CMH Lamp, Narrow Flood Upper Reflector, Lumen Rating = 3000 lms, Aromat Electronic Ballast
2500
5000
7500
10000
** Efficiency = 54.7% ** SC = .4 Certified Test Report No. 3950FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
39W PGJ5 Philips MiniMastercolor CMH Lamp, Flood Upper Reflector, Lumen Rating = 3000 lms, Aromat Electronic Ballast
600
1200
1800
2400
** Efficiency = 34.6% ** SC = .6 Certified Test Report No. 3937FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
10 1222
15 875 251
60°
20 565
25 325 159
30 162
35 78 56
40 36
45 24 21
50 22
55 19 16
60 15
30°
65 11 11
70 7
75 4 5
80 2
85 0 1
90 0
Angle Mean CP Lumens
0 9527
5 8449 749
10 4953
15 2214 710
60°
20 632
25 181 123
30 72
35 41 29
40 28
45 24 17
50 14
55 14 11
60 6
65 1 2
70 0
30°
75 0 0
80 0
85 0 0
90 0
Angle Mean CP Lumens
0 2404
5 2257 210
10 1901
15 1439 406
60°
20 955
25 549 269
30 270
35 125 90
40 55
45 33 29
50 29
55 24 21
60 17
65 11 11
30°
70 5
75 1 2
80 0
85 0 0
90 0
Luminance Summary
Angle Mean CD/SQ M
45 3360
55 3162
65 2446
75 1685
85 360
Zonal Lumens and Percentages
Zone Lumens %Lamp %Luminaire
0-30 550 33.36 83.46
0-40 606 36.73 91.9
0-60 643 38.98 97.52
0-90 659 39.97 100
40-90 53 3.24 8.1
60-90 16 0.99 2.48
90-180 0 0 0
0-180 659 39.97 100
Luminance Summary
Angle Mean CD/SQ M
45 3285
55 2340
65 325
75 0
85 0
Zonal Lumens and Percentages
Zone Lumens %Lamp %Luminaire
0-30 1581 52.72 96.4
0-40 1610 53.68 98.14
0-60 1638 54.61 99.85
0-90 1640 54.69 100
40-90 30 1.02 1.86
60-90 2 0.08 0.15
90-180 0 0 0
0-180 1640 54.69 100
Luminance Summary
Angle Mean CD/SQ M
45 4621
55 4069
65 2546
75 329
85 0
Zonal Lumens and Percentages
Zone Lumens %Lamp %Luminaire
0-30 885 29.52 85.24
0-40 976 32.53 93.94
0-60 1026 34.21 98.79
0-90 1038 34.63 100
40-90 62 2.1 6.06
60-90 12 0.42 1.21
90-180 0 0 0
0-180 1038 34.63 100
Coefficients of Utilization
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .48 . 48 .48 .4 8 .46 .46 .4 4 .44 .43 .43 . 40
1 .46 . 45 .44 .4 4 .4 4 .43 .43 .4 2 .41 .40 .39
2 .44 . 43 .42 .41 . 42 .40 .41 .39 .40 .38 .37
3 .43 . 41 .39 . 38 .40 .38 .3 9 .37 .39 . 37 .3 6
4 .41 . 39 .38 . 36 .3 9 .36 .38 . 36 .3 7 .35 .34
5 .40 . 38 .36 . 35 .3 7 .34 .37 . 34 .3 6 .34 .33
6 .39 . 36 .35 . 33 .3 6 .33 .35 . 33 .3 5 .33 .32
7 .38 . 35 .33 . 32 .3 5 .32 .34 . 32 .3 4 .32 .31
8 .37 . 34 .32 . 31 .3 3 .31 .33 . 31 .3 3 .31 .30
9 .35 . 33 .31 . 30 .3 2 .30 .32 . 30 .3 2 .29 .29
10 .34 . 32 .30 . 29 .31 .29 .31 .29 .31 .29 .28
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
Coefficients of Utilization
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .65 . 65 .65 . 65 .6 4 .64 .61 . 61 .5 8 .58 .55
1 .63 . 62 .62 . 61 .61 .60 .5 9 .58 .57 .56 . 54
2 .62 . 60 .59 . 58 .5 9 .57 .58 . 56 .5 6 .55 .53
3 .60 . 59 .57 . 56 .5 8 .56 .57 . 55 .5 6 .54 .52
4 .59 . 57 .56 . 54 .5 7 .54 .56 . 53 .5 5 .53 .52
5 .58 . 56 .54 . 53 .5 5 .53 .54 . 52 .5 4 .52 .51
6 .57 . 55 .53 . 52 .5 4 .52 .54 . 51 .5 3 .51 .50
7 .56 . 54 .52 . 51 .53 .51 .53 .50 .52 .50 .49
8 .55 . 53 .51 . 50 .52 .50 .5 2 .50 .51 .49 . 49
9 .54 . 52 .50 .4 9 .52 .49 .51 .49 .51 .49 .48
10 .54 . 51 . 49 .48 .51 . 48 .5 0 .48 .50 . 48 .48
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
Coefficients of Utilization
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .41 . 41 .41 .41 .4 0 .40 .38 .38 .37 .37 .35
1 .40 . 39 .38 . 38 .3 8 .37 .37 . 36 .3 6 .35 .34
2 .38 . 37 .36 . 35 .3 7 .35 .36 . 34 .3 5 .34 .32
3 .37 . 36 .34 . 33 .3 5 .33 .34 . 33 .3 4 .32 .31
4 .36 . 34 .33 . 32 .3 4 .32 .33 . 31 .3 3 .31 .30
5 .35 . 33 .31 . 30 .3 3 .30 .32 . 30 .31 .30 .29
6 .34 . 32 .30 . 29 .3 2 .29 .31 . 29 .31 .29 .28
7 .33 . 31 .29 . 28 .3 0 .28 .30 . 28 .3 0 .28 .27
8 .32 . 30 .28 . 27 .2 9 .27 .29 . 27 .2 9 .27 .26
9 .31 . 29 .27 . 26 .2 8 .26 .28 . 26 .2 8 .26 .25
10 .30 . 28 .26 . 25 .28 .25 .2 7 .25 .27 . 25 .25
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
Luminaire Input Watts = 25
Luminaire Input Watts = 25
Luminaire Input Watts = 45
Luminaire Input Watts = 45
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609
Job Information Type:
Calculite
®
HID Lensed Downlight C4T4GD-MHT4R
Page 4 of 4 4 1/2" Aperture, GU6.5 Glasslite
20W GU6.5 GE Constantcolor CMH Lamp, Narrow Flood Upper Reflector, Lumen Rating = 1615 lms, Aromat Electronic Ballast
Angle Mean CP Lumens
0 5807
5 4630 419
1500
3000
4500
6000
** Efficiency = 56.8% ** SC = .3 Certified Test Report No. 3955FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
10 2504
15 1091 364
60°
20 457
25 143 92
30 52
35 26 19
40 17
45 14 11
50 11
55 8 7
60 5
65 4 3
70 2
75 1 1
30°
80 0
85 0 0
90 0
Luminance Summary
Angle Mean CD/SQ M
45 1985
55 1336
65 868
75 398
85 0
Zonal Lumens and Percentages
Zone Lumens %Lamp %Luminaire
0-30 875 54.23 95.48
0-40 894 55.41 97.55
0-60 912 56.52 99.5
0-90 917 56.8 100
40-90 22 1.39 2.45
60-90 4 0.28 0.5
90-180 0 0 0
0-180 917 56.8 100
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .68 . 68 .68 . 68 .6 6 .66 .63 . 63 .6 0 .60 .57
1 .66 . 65 .64 . 63 .6 4 .62 .61 . 60 .5 9 .59 .56
2 .64 . 63 .61 . 60 .6 2 .59 .60 . 58 .5 8 .57 .55
3 .63 . 61 .59 . 58 .6 0 .57 .59 . 57 .57 .56 .54
4 .61 . 59 .57 . 56 .5 9 .56 .58 . 55 .5 6 .55 .53
5 .60 . 58 .56 . 54 .5 7 .54 .56 . 54 .5 5 .53 .52
6 .59 . 57 .55 . 53 .5 6 .53 .55 . 53 .5 5 .53 .52
7 .58 . 55 .54 . 52 .5 5 .52 .54 . 52 .5 4 .52 .51
8 .57 . 54 .52 . 51 .54 .51 .53 .51 .53 .51 .50
9 .56 . 53 .52 . 50 .5 3 .50 .53 . 50 .52 .50 .49
10 .55 . 52 .51 .4 9 .52 .49 .52 .49 .5 2 .49 .49
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
20W GU6.5 GE Constantcolor CMH Lamp, Flood Upper Reflector, Lumen Rating = 1615 lms, Aromat Electronic Ballast
Angle Mean CP Lumens
0 1085
5 1050 98
250
500
750
1000
** Efficiency = 32.6% ** SC = .6 Certified Test Report No. 3954FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
39W GU6.5 GE Constantcolor CMH Lamp, Narrow Flood Upper Reflector, Lumen Rating = 3400 lms, Aromat Electronic Ballast
2500
5000
7500
10000
** Efficiency = 52.9% ** SC = .3 Certified Test Report No. 3947FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
39W GU6.5 GE Constantcolor CMH Lamp, Flood Upper Reflector, Lumen Rating = 3400 lms, Aromat Electronic Ballast
750
1500
2250
3000
** Efficiency = 35.4% ** SC = .5 Certified Test Report No. 3948FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
10 928
15 717 201
60°
20 476
25 270 134
30 138
35 70 49
40 32
45 21 18
50 18
55 16 14
60 12
65 8 9
70 6
75 3 4
30°
80 1
85 0 0
90 0
Angle Mean CP Lumens
0 10898
5 8996 814
10 5237
15 2194 732
60°
20 704
25 222 144
30 99
35 66 44
40 46
45 36 29
50 32
55 27 23
60 17
65 10 10
70 4
75 1 2
30°
80 0
85 0 0
90 0
Angle Mean CP Lumens
0 3100
5 3104 276
10 2277
15 1586 458
60°
20 1011
25 570 283
30 292
35 146 102
40 67
45 43 37
50 38
55 31 28
60 24
65 15 16
70 9
75 3 4
30°
80 1
85 1 0
90 0
Luminance Summary
Angle Mean CD/SQ M
45 2918
55 2750
65 1957
75 1315
85 44
Zonal Lumens and Percentages
Zone Lumens %Lamp %Luminaire
0-30 432 26.8 82.25
0-40 481 29.82 91.51
0-60 513 31.8 97.6
0-90 526 32.58 100
40-90 44 2.77 8.49
60-90 12 0.78 2.4
90-180 0 0 0
0-180 526 32.58 100
Luminance Summary
Angle Mean CD/SQ M
45 5009
55 4601
65 2300
75 402
85 0
Zonal Lumens and Percentages
Zone Lumens %Lamp %Luminaire
0-30 1690 49.72 94.01
0-40 1734 51 96.44
0-60 1786 52.54 99.33
0-90 1798 52.89 100
40-90 64 1.88 3.56
60-90 11 0.35 0.67
90-180 0 0 0
0-180 1798 52.89 100
Luminance Summary
Angle Mean CD/SQ M
45 5891
55 5361
65 3434
75 1086
85 592
Zonal Lumens and Percentages
Zone Lumens %Lamp %Luminaire
0-30 1017 29.92 84.46
0-40 1119 32.92 92.95
0-60 1184 34.83 98.33
0-90 1204 35.42 100
40-90 84 2.5 7.05
60-90 20 0.59 1.67
90-180 0 0 0
0-180 1204 35.42 100
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .39 . 39 .39 . 39 .3 8 .38 .36 . 36 .3 5 .35 .33
1 .37 . 37 .36 . 36 .3 6 .35 .35 . 34 .3 4 .33 .31
2 .36 . 35 .34 . 33 .3 4 .33 .33 . 32 .3 2 .31 .30
3 .35 . 33 .32 . 31 .3 3 .31 .32 . 30 .31 .30 .29
4 .34 . 32 .31 . 30 .3 2 .29 .31 . 29 .3 0 .29 .28
5 .33 . 31 .29 . 28 .3 0 .28 .30 . 28 .2 9 .27 .27
6 .32 . 29 .28 . 27 .2 9 .27 .29 . 27 .2 8 .26 .26
7 .30 . 28 .27 . 26 .2 8 .26 .28 . 26 .2 7 .25 .25
8 .30 . 27 .26 . 25 .2 7 .25 .27 . 25 .2 6 .24 .24
9 .29 . 26 .25 . 24 .26 .24 .26 .24 .26 .24 .23
10 .28 . 25 .24 . 23 .25 .23 .25 .23 .2 5 .23 .22
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .63 . 63 .63 . 63 .61 .61 .5 9 .59 .56 .56 . 53
1 .61 . 60 .59 . 59 .5 9 .58 .57 . 56 .5 5 .54 .52
2 .60 . 58 .57 . 56 .5 7 .55 .55 . 54 .5 4 .53 .51
3 .58 . 56 .55 . 53 .5 6 .53 .54 . 52 .5 3 .52 .50
4 .57 . 55 .53 . 52 .5 4 .51 .53 . 51 .52 .50 .49
5 .56 . 53 .51 . 50 .5 3 .50 .52 . 50 .51 .49 .48
6 .55 . 52 .50 .4 9 .52 .49 .51 .49 .51 .49 .48
7 .54 . 51 .49 .4 8 .51 .48 .5 0 .48 .50 . 48 .47
8 .53 . 50 .48 .47 . 50 .47 .49 .47 .49 .47 .46
9 .52 . 49 .48 .4 6 .49 .46 .4 9 .46 .48 .46 . 46
10 .51 .4 8 .47 .4 6 .48 .46 .48 .45 .4 8 .45 .45
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .42 . 42 .42 .4 2 .41 .41 .3 9 .39 .38 .38 . 35
1 .41 . 40 .39 . 39 .3 9 .38 .38 . 37 .3 7 .36 .34
2 .39 . 38 .37 . 36 .3 7 .36 .36 . 35 .3 5 .34 .33
3 .38 . 36 .35 . 34 .3 6 .34 .35 . 33 .3 4 .33 .32
4 .37 . 35 .34 . 33 .3 5 .32 .34 . 32 .3 3 .32 .31
5 .36 . 34 .32 . 31 .3 3 .31 .33 . 31 .3 2 .30 .30
6 .35 . 32 .31 . 30 .3 2 .30 .32 . 30 .31 .29 .29
7 .34 . 31 .30 . 29 .31 .29 .31 .29 . 30 .28 .28
8 .33 . 30 .29 . 28 .3 0 .28 .30 . 28 .2 9 .27 .27
9 .32 . 29 .28 . 27 .2 9 .27 .29 . 27 .2 9 .26 .26
10 .31 . 28 .27 . 26 .28 .26 .2 8 .26 .28 . 26 .25
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
Coefficients of Utilization
Luminaire Input Watts = 25
Coefficients of Utilization
Luminaire Input Watts = 25
Coefficients of Utilization
Luminaire Input Watts = 45
Coefficients of Utilization
Luminaire Input Watts = 45
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609
Job Information Type: