Philips Calculite C4T4GD-MHT4R, Lightolier Calculite C4T4GD-MHT4R Specification

®
HID Lensed Downlight C4T4GD-MHT4R
Page 1 of 4 4 1/2" Aperture, T4 Ceramic Metal Halide, Glasslite
Ceiling Cutout: 5 1/8” (130 mm) Dia.
For complete fixture order: Trim Kit (Glasslite) + Upper Reflector + Frame-In Kit. Sold Separately
Glasslite Trim Kit + Upper Reflector Frame-In Kit
C4T4GD +
MHT4RS (Spot Upper Reflector) MHT4RNF (Narrow Flood Upper Reflector) MHT4RF (Flood Upper Reflector)
C4A20BT5PGJ5E1 C4A20T4GU6 5EU C4A20T4EU C4A39T4GU65EU C4A39T4E1 C4A39T4E2 C4A70 T4E1 C4A70 T4E2
Features
1. Upper Reflector: Specular faceted aluminum; select 12° Spot (MHT4RS) 25°
Narrow Flood (MHT4RNF) or 40° Flood (MHT4RF); interchangeable.
2. Glasslite Trim Kit: One piece borosilicate etched glass.
3. Lamp Holder: Unitized construction assures proper alignment of lamp to
optics for consistent optical performance.
4. Socket Housing: Galvanized steel, pre-wired with G8.5 pulse rated
socket. Snaps onto yoke for secure attachment without tools; unitized construction assures proper alignment of lamp to optics for consistent optical
performance.
5. Frame Housing: Steel, 0.029" (22-Ga.), matte black finish. Removable cover
for top re-lamping.
6. Frame Vertical Adjustment Mechanism: Accommodates mounting to
virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below from inside fixture.
7. Mounting Bars: Galvanized steel, 0.048" (18-ga.), pre-installed telescoping
bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories.
8. Retention Springs: Rust resistant springs secure trim for quick, tool-less
installation.
9. Ballast / Cover Assembly: Accessible from below and removable without
tools for inspection and ballast replacement .
10. Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90° C through branch circuit conductors. Allows inspection from below.
11. Optional Accessory Holder: Catalog # CAH4 Sold separately; die-formed
steel, matte black finish, slide-in installation. Accepts up to two 3 3/4" dia.
media.
Lamping (Ceramic Metal Halide)
Electronic 120V
Electronic 120V/277V Electronic 120V/277V Electronic 120V/277V
Electronic 120V Electronic 277V Electronic 120V Electronic 277V
22W Philips MiniMasterColor 20W GE ConstantColor 20W T4.5 39W Philips MiniMasterColor 39W T4.5 39W T4.5 70W T4.5 70W T4.5
Features (continued)
12. Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high power factor, T.H.D.
<15%, thermally and transient protected, RMI/RFI complies with FCC Part 18 non-consumer limits, shut-down circuit at end of lamp life, sound rating “A”,
-5° F minimum starting temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
20W MH M156 120/277 0.21/0.10 23 39W MH M130 120/277 0.39/0.17 44 70W MH M139 120/277 0.67/0.29 78
Options and Accessories
Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Wet Locations), CSA, I.B.E.W.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609
®
HID Lensed Downlight C4T4GD-MHT4R
Page 2 of 4 4 1/2" Aperture, T4.5 Ceramic Metal Halide, Glasslite
39W T4.5 Ceramic MH, Narrow Flood Upper Reflector, Philips, Lumen Rating = 3400 LMS., Aromat Electronic Ballast
ANGLE MEAN CP LUMENS 0 8996 5 7584
2,250
4,500
6,750
9,000
** Efficiency = 46.7% ** SC = .3 Certified Test Report No. 18678FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**
10 4322 15 2225 20 1047
60°
25 452 30 169 35 81 40 53 45 39 50 32 55 26
60 20
65 12
70 7
75 5 80 3 85 0
30°
90 0
LUMINANCE SUMMARY - CD. / SQ. M. ANGLE MEAN CD/SQ M 45 7690 55 6459 65 3966 75 2612 85 0
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 1459 42.92 91.95 0-40 1515 44.58 95.5 0-60 1569 46.16 98.88 0-90 1587 46.68 100 40-90 71 2.1 4.5 60-90 17 0.52 1.12 90-180 0 0 0 0-180 1587 46.68 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .56 .56 .56 .56 .54 .54 .52 .52 .50 .50 .47 1 .54 .53 .52 .51 .52 .51 .50 .49 .48 .48 .46 2 .52 .51 .50 .49 .50 .48 .49 .47 .47 .46 .44 3 .51 .49 .48 .47 .48 .46 .47 .46 .46 .45 .44 4 .50 .48 .46 .45 .47 .45 .46 .44 .45 .44 .43 5 .49 .46 .45 .43 .46 .43 .45 .43 .44 .42 .42 6 .48 .45 .43 .42 .45 .42 .44 .42 .44 .42 .41 7 .46 .44 .42 .41 .44 .41 .43 .41 .43 .41 .40 8 .46 .43 .41 .40 .43 .40 .42 .40 .42 .40 .39 9 .45 .42 .41 .39 .42 .39 .42 .39 .41 .39 .39 10 .44 .41 .40 .38 .41 .38 .41 .38 .40 .38 .38
LUMINAIRE INPUT WATTS = 44
70W T4.5 Ceramic MH, Narrow Flood Upper Reflector, Philips, Lumen Rating = 6200 LMS., Aromat Electronic Ballast
ANGLE MEAN CP LUMENS 0 13659 5 11121 915
3,750
7,500
11,250
15,000
** Efficiency = 42.4% ** SC = .3 Certified Test Report No.18753FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**
10 6556 15 3509 990 20 1859
60°
25 942 441 30 400 35 177 125 40 105 45 78 62 50 65 55 55 49 60 43 65 29 30
70 20
75 11 12 80 6 85 1 2
30°
90 0
LUMINANCE SUMMARY - CD. / SQ. M. ANGLE MEAN CD/SQ M 45 15547 55 13566 65 9819 75 6013 85 2289
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 2346 37.85 89.35 0-40 2471 39.87 94.11 0-60 2582 41.65 98.32 0-90 2626 42.36 100 40-90 154 2.49 5.89 60-90 44 0.71 1.68 90-180 0 0 0 0-180 2626 42.36 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .50 .50 .50 .50 .49 .49 .47 .47 .45 .45 .42 1 .49 .48 .47 .46 .47 .46 .45 .44 .44 .43 .41 2 .47 .46 .45 .44 .45 .43 .44 .42 .43 .41 .40 3 .46 .44 .43 .42 .44 .41 .43 .41 .42 .40 .39 4 .45 .43 .41 .40 .42 .40 .41 .39 .41 .39 .38 5 .44 .41 .40 .39 .41 .38 .40 .38 .40 .38 .37 6 .43 .40 .39 .37 .40 .37 .39 .37 .39 .37 .36 7 .41 .39 .37 .36 .39 .36 .38 .36 .38 .36 .35 8 .41 .38 .36 .35 .38 .35 .37 .35 .37 .35 .34 9 .40 .37 .36 .34 .37 .34 .37 .34 .36 .34 .34 10 .39 .36 .35 .34 .36 .34 .36 .34 .36 .33 .33
LUMINAIRE INPUT WATTS = 78
39W T4.5 Ceramic MH, Flood Upper Reflector, Philips, Lumen Rating = 3400 LMS. Aromat Electronic Ballast
ANGLE MEAN CP LUMENS 0 1992 5 1944 184
500
1,000
1,500
2,000
** Efficiency = 33.1% ** SC = .7 Certified Test Report No.18679FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**
10 1822 15 1660 444
20 1226
60°
25 706 322 30 315 35 139 95 40 66 45 36 31 50 30 55 26 23
60 21
65 16 16
70 11
75 7 8 80 4 85 1 2
30°
90 0
LUMINANCE SUMMARY - CD. / SQ. M. ANGLE MEAN CD/SQ M 45 7192 55 6459 65 5333 75 3973 85 2101
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 949 27.94 84.42 0-40 1045 30.74 92.9 0-60 1099 32.34 97.74 0-90 1125 33.09 100 40-90 79 2.35 7.1 60-90 25 0.75 2.26 90-180 0 0 0 0-180 1125 33.09 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .39 .39 .39 .39 .37 .38 .38 .38 .35 .35 .33 1 .38 .37 .37 .36 .35 .37 .37 .35 .34 .33 .32 2 .37 .35 .34 .33 .33 .36 .35 .33 .33 .32 .30 3 .35 .34 .33 .31 .32 .35 .33 .31 .32 .30 .29 4 .34 .32 .31 .30 .30 .34 .32 .30 .31 .29 .28 5 .33 .31 .30 .28 .29 .33 .31 .28 .30 .28 .27 6 .32 .30 .28 .27 .28 .32 .30 .27 .29 .27 .26 7 .31 .29 .27 .26 .27 .31 .29 .26 .28 .26 .25 8 .30 .28 .26 .25 .26 .30 .27 .25 .27 .25 .25 9 .29 .27 .25 .24 .25 .29 .27 .24 .26 .24 .24 10 .28 .26 .24 .23 .24 .28 .26 .23 .25 .23 .23
LUMINAIRE INPUT WATTS = 44
70W T4.5 Ceramic MH, Flood Upper Reflector, Philips, Lumen Rating = 6200 LMS., Aromat Electronic Ballast
ANGLE MEAN CP LUMENS
0 3172
5 3144 303
750
1,500
2,250
3,000
** Efficiency = 32.6% ** SC = .7 Certified Test Report No.18755FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**
10 3054 15 2810 763 20 2215
60°
25 1361 618 30 668 35 279 194 40 125 45 67 57 50 55 55 47 42 60 39 65 29 29
70 20
75 13 14 80 8 85 3 3
30°
90 0
LUMINANCE SUMMARY - CD. / SQ. M. ANGLE MEAN CD/SQ M 45 13385 55 11655 65 9620 75 7313 85 4282
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 1684 27.16 83.2 0-40 1878 30.29 92.79 0-60 1977 31.9 97.71 0-90 2024 32.65 100 40-90 145 2.35 7.21 60-90 46 0.75 2.29 90-180 0 0 0 0-180 2024 32.65 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
RCR
0 .39 .39 .39 .39 .38 .38 .36 .36 .35 .35 .33 1 .37 .37 .36 .35 .36 .35 .35 .34 .33 .33 .31 2 .36 .35 .34 .33 .34 .32 .33 .32 .32 .31 .30 3 .35 .33 .32 .31 .33 .31 .32 .30 .31 .30 .29 4 .34 .32 .30 .29 .31 .29 .31 .29 .30 .29 .28 5 .32 .30 .29 .28 .30 .28 .30 .28 .29 .27 .27 6 .31 .29 .28 .27 .29 .27 .29 .27 .28 .26 .26 7 .30 .28 .27 .26 .28 .25 .27 .25 .27 .25 .25 8 .29 .27 .26 .25 .27 .24 .27 .24 .26 .24 .24 9 .28 .26 .25 .24 .26 .24 .26 .23 .25 .23 .23 10 .28 .25 .24 .23 .25 .23 .25 .23 .25 .23 .22
LUMINAIRE INPUT WATTS = 78
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609
Job Information Type:
®
HID Lensed Downlight C4T4GD-MHT4R
Page 3 of 4 4 1/2" Aperture, PGJ5 Glasslite
22W PGJ5 Philips MiniMastercolor CMH Lamp, Narrow Flood Upper Reflector, Lumen Rating = 1650 lms, Aromat Electronic Ballast
Angle Mean CP Lumens 0 5817 5 5387 471
1500
3000
4500
6000
** Efficiency = 62.1% ** SC = .4 Certified Test Report No. 3951FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
10 3158 15 1324 435
60°
20 339 25 107 69 30 45 35 29 19 40 18 45 16 12 50 13 55 11 10 60 8 65 6 6
30°
70 3
75 2 2 80 1 85 0 0 90 0
Luminance Summary Angle Mean CD/SQ M 45 2252 55 1858 65 1354 75 762 85 0
Zonal Lumens and Percentages Zone Lumens %Lamp %Luminaire 0-30 975 59.15 95.24 0-40 994 60.3 97.09 0-60 1016 61.63 99.23 0-90 1024 62.11 100 40-90 29 1.81 2.91 60-90 7 0.48 0.77 90-180 0 0 0 0-180 1024 62.11 100
Coefficients of Utilization
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .74 .74 .74 .74 .72 .72 .6 9 . 69 .6 6 .66 .62 1 .72 .71 .70 .69 .70 .68 .67 .66 .6 5 .64 .61 2 .70 . 68 .67 . 66 .6 7 .65 .65 . 63 .6 4 .62 .60 3 .68 . 66 .65 . 63 .6 5 .63 .64 . 62 .6 3 .61 .59 4 .67 . 65 .63 . 61 .6 4 .61 .63 . 60 .6 2 .60 .58 5 .66 . 63 .61 . 60 .6 2 .59 .61 . 59 .61 .58 .57 6 .65 . 62 .60 . 58 .61 .58 .61 .58 .6 0 .58 .57 7 .63 . 61 .59 . 57 .6 0 .57 .59 . 57 .5 9 .56 .56 8 .63 . 59 .57 . 56 .5 9 .56 .59 . 56 .5 8 .56 .55 9 .61 . 58 .57 . 55 .5 8 .55 .58 . 55 .57 .55 .54 10 .61 . 57 .56 .5 4 .57 .54 .57 .54 .5 7 .54 .54
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
22W PGJ5 Philips MiniMastercolor CMH Lamp, Flood Upper Reflector, Lumen Rating = 1650 lms, Aromat Electronic Ballast
Angle Mean CP Lumens
0 1632
5 1513 140
400
800
1200
1600
** Efficiency = 40.0% ** SC = .5 Certified Test Report No. 3935FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
39W PGJ5 Philips MiniMastercolor CMH Lamp, Narrow Flood Upper Reflector, Lumen Rating = 3000 lms, Aromat Electronic Ballast
2500
5000
7500
10000
** Efficiency = 54.7% ** SC = .4 Certified Test Report No. 3950FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
39W PGJ5 Philips MiniMastercolor CMH Lamp, Flood Upper Reflector, Lumen Rating = 3000 lms, Aromat Electronic Ballast
600
1200
1800
2400
** Efficiency = 34.6% ** SC = .6 Certified Test Report No. 3937FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
10 1222
15 875 251
60°
20 565 25 325 159
30 162
35 78 56 40 36 45 24 21 50 22 55 19 16 60 15
30°
65 11 11
70 7
75 4 5 80 2 85 0 1 90 0
Angle Mean CP Lumens 0 9527 5 8449 749 10 4953 15 2214 710
60°
20 632
25 181 123
30 72
35 41 29 40 28 45 24 17 50 14 55 14 11
60 6
65 1 2
70 0
30°
75 0 0 80 0 85 0 0 90 0
Angle Mean CP Lumens 0 2404 5 2257 210 10 1901 15 1439 406
60°
20 955 25 549 269
30 270
35 125 90 40 55 45 33 29 50 29 55 24 21
60 17
65 11 11
30°
70 5 75 1 2 80 0 85 0 0 90 0
Luminance Summary Angle Mean CD/SQ M 45 3360 55 3162 65 2446 75 1685 85 360
Zonal Lumens and Percentages Zone Lumens %Lamp %Luminaire 0-30 550 33.36 83.46 0-40 606 36.73 91.9 0-60 643 38.98 97.52 0-90 659 39.97 100 40-90 53 3.24 8.1 60-90 16 0.99 2.48 90-180 0 0 0 0-180 659 39.97 100
Luminance Summary Angle Mean CD/SQ M 45 3285 55 2340 65 325 75 0 85 0
Zonal Lumens and Percentages Zone Lumens %Lamp %Luminaire 0-30 1581 52.72 96.4 0-40 1610 53.68 98.14 0-60 1638 54.61 99.85 0-90 1640 54.69 100 40-90 30 1.02 1.86 60-90 2 0.08 0.15 90-180 0 0 0 0-180 1640 54.69 100
Luminance Summary Angle Mean CD/SQ M 45 4621 55 4069 65 2546 75 329 85 0
Zonal Lumens and Percentages Zone Lumens %Lamp %Luminaire 0-30 885 29.52 85.24 0-40 976 32.53 93.94 0-60 1026 34.21 98.79 0-90 1038 34.63 100 40-90 62 2.1 6.06 60-90 12 0.42 1.21 90-180 0 0 0 0-180 1038 34.63 100
Coefficients of Utilization
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .48 . 48 .48 .4 8 .46 .46 .4 4 .44 .43 .43 . 40 1 .46 . 45 .44 .4 4 .4 4 .43 .43 .4 2 .41 .40 .39 2 .44 . 43 .42 .41 . 42 .40 .41 .39 .40 .38 .37 3 .43 . 41 .39 . 38 .40 .38 .3 9 .37 .39 . 37 .3 6 4 .41 . 39 .38 . 36 .3 9 .36 .38 . 36 .3 7 .35 .34 5 .40 . 38 .36 . 35 .3 7 .34 .37 . 34 .3 6 .34 .33 6 .39 . 36 .35 . 33 .3 6 .33 .35 . 33 .3 5 .33 .32 7 .38 . 35 .33 . 32 .3 5 .32 .34 . 32 .3 4 .32 .31 8 .37 . 34 .32 . 31 .3 3 .31 .33 . 31 .3 3 .31 .30 9 .35 . 33 .31 . 30 .3 2 .30 .32 . 30 .3 2 .29 .29 10 .34 . 32 .30 . 29 .31 .29 .31 .29 .31 .29 .28
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
Coefficients of Utilization
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .65 . 65 .65 . 65 .6 4 .64 .61 . 61 .5 8 .58 .55 1 .63 . 62 .62 . 61 .61 .60 .5 9 .58 .57 .56 . 54 2 .62 . 60 .59 . 58 .5 9 .57 .58 . 56 .5 6 .55 .53 3 .60 . 59 .57 . 56 .5 8 .56 .57 . 55 .5 6 .54 .52 4 .59 . 57 .56 . 54 .5 7 .54 .56 . 53 .5 5 .53 .52 5 .58 . 56 .54 . 53 .5 5 .53 .54 . 52 .5 4 .52 .51 6 .57 . 55 .53 . 52 .5 4 .52 .54 . 51 .5 3 .51 .50 7 .56 . 54 .52 . 51 .53 .51 .53 .50 .52 .50 .49 8 .55 . 53 .51 . 50 .52 .50 .5 2 .50 .51 .49 . 49 9 .54 . 52 .50 .4 9 .52 .49 .51 .49 .51 .49 .48 10 .54 . 51 . 49 .48 .51 . 48 .5 0 .48 .50 . 48 .48
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
Coefficients of Utilization
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .41 . 41 .41 .41 .4 0 .40 .38 .38 .37 .37 .35
1 .40 . 39 .38 . 38 .3 8 .37 .37 . 36 .3 6 .35 .34 2 .38 . 37 .36 . 35 .3 7 .35 .36 . 34 .3 5 .34 .32 3 .37 . 36 .34 . 33 .3 5 .33 .34 . 33 .3 4 .32 .31 4 .36 . 34 .33 . 32 .3 4 .32 .33 . 31 .3 3 .31 .30 5 .35 . 33 .31 . 30 .3 3 .30 .32 . 30 .31 .30 .29 6 .34 . 32 .30 . 29 .3 2 .29 .31 . 29 .31 .29 .28 7 .33 . 31 .29 . 28 .3 0 .28 .30 . 28 .3 0 .28 .27 8 .32 . 30 .28 . 27 .2 9 .27 .29 . 27 .2 9 .27 .26 9 .31 . 29 .27 . 26 .2 8 .26 .28 . 26 .2 8 .26 .25 10 .30 . 28 .26 . 25 .28 .25 .2 7 .25 .27 . 25 .25
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
Luminaire Input Watts = 25
Luminaire Input Watts = 25
Luminaire Input Watts = 45
Luminaire Input Watts = 45
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609
Job Information Type:
®
HID Lensed Downlight C4T4GD-MHT4R
Page 4 of 4 4 1/2" Aperture, GU6.5 Glasslite
20W GU6.5 GE Constantcolor CMH Lamp, Narrow Flood Upper Reflector, Lumen Rating = 1615 lms, Aromat Electronic Ballast
Angle Mean CP Lumens 0 5807 5 4630 419
1500
3000
4500
6000
** Efficiency = 56.8% ** SC = .3 Certified Test Report No. 3955FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
10 2504 15 1091 364
60°
20 457 25 143 92 30 52 35 26 19 40 17 45 14 11 50 11 55 8 7 60 5 65 4 3
70 2
75 1 1
30°
80 0 85 0 0 90 0
Luminance Summary Angle Mean CD/SQ M 45 1985 55 1336 65 868 75 398 85 0
Zonal Lumens and Percentages Zone Lumens %Lamp %Luminaire 0-30 875 54.23 95.48 0-40 894 55.41 97.55 0-60 912 56.52 99.5 0-90 917 56.8 100 40-90 22 1.39 2.45 60-90 4 0.28 0.5 90-180 0 0 0 0-180 917 56.8 100
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .68 . 68 .68 . 68 .6 6 .66 .63 . 63 .6 0 .60 .57 1 .66 . 65 .64 . 63 .6 4 .62 .61 . 60 .5 9 .59 .56 2 .64 . 63 .61 . 60 .6 2 .59 .60 . 58 .5 8 .57 .55 3 .63 . 61 .59 . 58 .6 0 .57 .59 . 57 .57 .56 .54 4 .61 . 59 .57 . 56 .5 9 .56 .58 . 55 .5 6 .55 .53 5 .60 . 58 .56 . 54 .5 7 .54 .56 . 54 .5 5 .53 .52 6 .59 . 57 .55 . 53 .5 6 .53 .55 . 53 .5 5 .53 .52 7 .58 . 55 .54 . 52 .5 5 .52 .54 . 52 .5 4 .52 .51 8 .57 . 54 .52 . 51 .54 .51 .53 .51 .53 .51 .50 9 .56 . 53 .52 . 50 .5 3 .50 .53 . 50 .52 .50 .49 10 .55 . 52 .51 .4 9 .52 .49 .52 .49 .5 2 .49 .49
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
20W GU6.5 GE Constantcolor CMH Lamp, Flood Upper Reflector, Lumen Rating = 1615 lms, Aromat Electronic Ballast
Angle Mean CP Lumens 0 1085 5 1050 98
250
500
750
1000
** Efficiency = 32.6% ** SC = .6 Certified Test Report No. 3954FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
39W GU6.5 GE Constantcolor CMH Lamp, Narrow Flood Upper Reflector, Lumen Rating = 3400 lms, Aromat Electronic Ballast
2500
5000
7500
10000
** Efficiency = 52.9% ** SC = .3 Certified Test Report No. 3947FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
39W GU6.5 GE Constantcolor CMH Lamp, Flood Upper Reflector, Lumen Rating = 3400 lms, Aromat Electronic Ballast
750
1500
2250
3000
** Efficiency = 35.4% ** SC = .5 Certified Test Report No. 3948FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
10 928 15 717 201
60°
20 476 25 270 134 30 138 35 70 49 40 32 45 21 18 50 18 55 16 14
60 12
65 8 9
70 6
75 3 4
30°
80 1 85 0 0 90 0
Angle Mean CP Lumens 0 10898 5 8996 814 10 5237 15 2194 732
60°
20 704 25 222 144 30 99 35 66 44 40 46 45 36 29 50 32 55 27 23
60 17
65 10 10 70 4 75 1 2
30°
80 0 85 0 0 90 0
Angle Mean CP Lumens
0 3100
5 3104 276
10 2277
15 1586 458
60°
20 1011
25 570 283 30 292 35 146 102 40 67 45 43 37 50 38 55 31 28 60 24 65 15 16 70 9 75 3 4
30°
80 1 85 1 0 90 0
Luminance Summary Angle Mean CD/SQ M 45 2918 55 2750 65 1957 75 1315 85 44
Zonal Lumens and Percentages Zone Lumens %Lamp %Luminaire 0-30 432 26.8 82.25 0-40 481 29.82 91.51 0-60 513 31.8 97.6 0-90 526 32.58 100 40-90 44 2.77 8.49 60-90 12 0.78 2.4 90-180 0 0 0 0-180 526 32.58 100
Luminance Summary Angle Mean CD/SQ M 45 5009 55 4601 65 2300 75 402 85 0
Zonal Lumens and Percentages Zone Lumens %Lamp %Luminaire 0-30 1690 49.72 94.01 0-40 1734 51 96.44 0-60 1786 52.54 99.33 0-90 1798 52.89 100 40-90 64 1.88 3.56 60-90 11 0.35 0.67 90-180 0 0 0 0-180 1798 52.89 100
Luminance Summary Angle Mean CD/SQ M 45 5891 55 5361 65 3434 75 1086 85 592
Zonal Lumens and Percentages Zone Lumens %Lamp %Luminaire 0-30 1017 29.92 84.46 0-40 1119 32.92 92.95 0-60 1184 34.83 98.33 0-90 1204 35.42 100 40-90 84 2.5 7.05 60-90 20 0.59 1.67 90-180 0 0 0 0-180 1204 35.42 100
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .39 . 39 .39 . 39 .3 8 .38 .36 . 36 .3 5 .35 .33 1 .37 . 37 .36 . 36 .3 6 .35 .35 . 34 .3 4 .33 .31 2 .36 . 35 .34 . 33 .3 4 .33 .33 . 32 .3 2 .31 .30 3 .35 . 33 .32 . 31 .3 3 .31 .32 . 30 .31 .30 .29 4 .34 . 32 .31 . 30 .3 2 .29 .31 . 29 .3 0 .29 .28 5 .33 . 31 .29 . 28 .3 0 .28 .30 . 28 .2 9 .27 .27 6 .32 . 29 .28 . 27 .2 9 .27 .29 . 27 .2 8 .26 .26 7 .30 . 28 .27 . 26 .2 8 .26 .28 . 26 .2 7 .25 .25 8 .30 . 27 .26 . 25 .2 7 .25 .27 . 25 .2 6 .24 .24 9 .29 . 26 .25 . 24 .26 .24 .26 .24 .26 .24 .23 10 .28 . 25 .24 . 23 .25 .23 .25 .23 .2 5 .23 .22
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .63 . 63 .63 . 63 .61 .61 .5 9 .59 .56 .56 . 53 1 .61 . 60 .59 . 59 .5 9 .58 .57 . 56 .5 5 .54 .52 2 .60 . 58 .57 . 56 .5 7 .55 .55 . 54 .5 4 .53 .51 3 .58 . 56 .55 . 53 .5 6 .53 .54 . 52 .5 3 .52 .50 4 .57 . 55 .53 . 52 .5 4 .51 .53 . 51 .52 .50 .49 5 .56 . 53 .51 . 50 .5 3 .50 .52 . 50 .51 .49 .48 6 .55 . 52 .50 .4 9 .52 .49 .51 .49 .51 .49 .48 7 .54 . 51 .49 .4 8 .51 .48 .5 0 .48 .50 . 48 .47 8 .53 . 50 .48 .47 . 50 .47 .49 .47 .49 .47 .46 9 .52 . 49 .48 .4 6 .49 .46 .4 9 .46 .48 .46 . 46 10 .51 .4 8 .47 .4 6 .48 .46 .48 .45 .4 8 .45 .45
Ceiling 8 0% 70% 50% 30%
Wall 7 0 50 3 0 10 50 10 5 0 10 50 10 0
RCR
0 .42 . 42 .42 .4 2 .41 .41 .3 9 .39 .38 .38 . 35 1 .41 . 40 .39 . 39 .3 9 .38 .38 . 37 .3 7 .36 .34 2 .39 . 38 .37 . 36 .3 7 .36 .36 . 35 .3 5 .34 .33 3 .38 . 36 .35 . 34 .3 6 .34 .35 . 33 .3 4 .33 .32 4 .37 . 35 .34 . 33 .3 5 .32 .34 . 32 .3 3 .32 .31 5 .36 . 34 .32 . 31 .3 3 .31 .33 . 31 .3 2 .30 .30 6 .35 . 32 .31 . 30 .3 2 .30 .32 . 30 .31 .29 .29 7 .34 . 31 .30 . 29 .31 .29 .31 .29 . 30 .28 .28 8 .33 . 30 .29 . 28 .3 0 .28 .30 . 28 .2 9 .27 .27 9 .32 . 29 .28 . 27 .2 9 .27 .29 . 27 .2 9 .26 .26 10 .31 . 28 .27 . 26 .28 .26 .2 8 .26 .28 . 26 .25
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
Zonal C avity Me thod - Ef fective F loor Cavit y Reflec tance = 20%
Coefficients of Utilization
Luminaire Input Watts = 25
Coefficients of Utilization
Luminaire Input Watts = 25
Coefficients of Utilization
Luminaire Input Watts = 45
Coefficients of Utilization
Luminaire Input Watts = 45
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609
Job Information Type: