Philips LEDALITE TruGroove Series Installation Instructions Manual

System Overview
These instructions review how to install TruGroove Perimeter Ambient and Graze fixtures. Modules can be installed as individual standalone units, or they can be joined together to create continuous runs. The graphics below show the components required to install a typical run of TruGroove Perimeter fixtures. IMPORTANT: Read all instructions before beginning installation.
Wall Rail
On Grid End Set
On-grid endplate left (x1)
On-grid endplate right (x1)
#8 sheet metal screws (x6)
Joiner Kit
Joiner bracket (x1)
Biscuit aligners (x2)
#8 sheet metal screws (x2)
Tools Required:
Phillips Screwdriver #2 Robertson Screwdriver
Mount Spacing & Power Feed Location
TruGroove Perimeter modules are designed for exact on-grid mounting. 2 mount­ing and 2 power feed locations are available on each module. Refer to layout draw­ings or row configuration documents for module lengths and mounting distances.
Variable End Set
Variable endplate left (x1)
Variable endplate right (x1)
Variable panels (x2)
On-grid end caps (x2)
Grid clips (x2)
#8 sheet metal screws (x8)
Grid Panel Kit
Grid panel (x1)
Grid clips (x2)
#8 sheet metal screws (x3)
ATTENTION: Install in accordance with national and local building and electrical codes.
!
Ceiling preparation covers grid ceiling modifica­tions, attachment of wall rails and mount installation. Above diagram covers all required dimensions for standard t-grid installation. IMPORTANT: Grid opening size must be followed for proper fit.
Ceiling Preparation
1a
(Flat Wall)
Mount Installation
3
Ceiling bracket
Wall rail
Aach bracket to structure
(hardware by others)
Suspension cable
Optional: Textured walls. Above diagram covers all required dimensions for standard t-grid installation with a textured wall. IMPORTANT: To ensure a proper fit, blocking (by others) must be the same thickness as wall texture.
Ceiling Preparation
1b
(Textured Wall)
Boom edge of installed
xture
Power Feed Preparation
4
Wall rail
Suspension cable
Electrical conduit
(by others)
Wall Rail Installation 4” Regress
2a
Flat wall
shown
TruGroove perimeter fixture modules are available in two different above plenum heights. Refer to
layout drawings for required regress. Standard 4”
regress is shown in above diagram. Attach wall rails (hardware by others) to wall studs at specified height. IMPORTANT: Ensure all wall rails are level.
Fixture Installation
5
Hook
Wall Rail Installation 2” Regress
2b
Flat wall
shown
Optional 2” regress is shown in above diagram.
Attach wall rails (hardware by others) to wall studs at specified height. IMPORTANT: Ensure all wall rails are level.
Fixture Installation
6a
Ambient shown
Suspension cable
Refer to page 1 and steps 1a/1b above for determin­ing mounting locations. To install the 1st module, two brackets and suspension cables are required. When joining luminaires, only one bracket and sus­pension cable are required for each joining module.
ATTENTION: Install in accordance with national and local building and electrical codes.
!
Determine required power feel locations. Refer to page 1 for typical power feed locations for each housing. Prepare power feed drop conduit and suspend close to required location. Attachment to fixture module is shown in step 8.
Lift fixture module past ceiling plane, Tilt as shown and engage housing hook on wall rail.
Ambient shown
Insert suspension cables installed in step 3 through cable grippers inside fixture housing. IMPORTANT: Ensure suspension cables are vertical. Level fixture
and trim excess cable to 1” below fixture. Tuck
remaining cable inside fixture housing.
Engage housing on wall rail. Insert suspension cables installed in step 3 through cable grippers inside fix­ture housing. Pull cables through and refer to next step for levelling. IMPORTANT: Remove graze pack­aging insert from both ends of each housing.
Fixture Installation
6b
Remove packaging insert
Fixture Joining
10
Graze shown
Fixture Installation
7
To adjust fixture level, support bottom of housing and release cable gripper by pulling tab as shown. Cable will slide freely and allow fine tuning of housing position. Repeat process at each cable gripper loca­tion using same procedure to ensure housing is level.
Fixture Joining
11
Release tab
5⁰ max. cable
deviaon
from vercal
Graze shown
Power Feed Connection
8
Break 7/8” knockout at end of housing at required
power feed location. Install conduit connector (by others) and complete electrical connections. For a row end, tuck wires inside wiring cavity and follow endplate installation instructions starting in step 13.
Flat End Installation
12
Fixture Joining
9
Slide dimpled side of joiner bracket approximately 1 inch inside top channel of module 1. Tap biscuit aligners just past half way inside module 2 as shown.
Flat End Installation
13
Secure joiner bracket to module 1 with screw pro­vided. Slide module 2 on rail and engage on free end of joiner bracket. Complete all required electrical connections and tuck all wires inside both wiring cavities.
ATTENTION: Install in accordance with national and local building and electrical codes.
!
IMPORTANT: Before sliding fixtures together, make sure all electrical wires and suspension cables are properly tucked inside fixture wiring cavities. Slide fixture housings together and attach second joiner bracket screw.
For variable end installation, skip to step 14b.
Rotate and position bottom of endplate inside grid and push flat against housing end.
Secure endplate to housing with 3 screws as shown.
14a
NOTE: Installed at endplate orientaon
IMPORTANT: Flat endplate must be oriented and installed as shown above. If variable ends are not required, skip to step 17 for panel installation.
17
Flat End Installation
Panel Installation – On Grid
14b
After fixture modules have been installed and lev­elled, measure distance between wall and fixture end. Trim variable endplate as required. INSTALLATION TIP: Before next step, attach 2 screws shown above to housing. Fully tighten then back off 1/2 turn.
18
Variable End Installation
Trim endplate as needed
Panel Installation
Variable End Installation
15
After variable endplate has been trimmed to size, slide endplate toward wall guiding open slots to­wards screws installed in step 14b. Hook slots on screws and push all the way towards wall.
Panel Installation
19
Variable End Installation
16
Check that endplate edge is flush with housing and attach final screw to lock in place.
Panel Installation
20
Grid panel
Trim at
grid end
Before installing grid panels, all panels ending on grid must be trimmed as shown. Ensure one left and one right are trimmed for each required run.
ATTENTION: Install in accordance with national and local building and electrical codes.
!
Insert grid clips (x2) to grid panel at slot locations. Push grid clip up as shown until bottom of clip is flush with bottom of grid panel.
Starting at one end, align first grid panel with end of housing and slide onto t-grid to engage clips.
Secure grid panel to housing by attaching provided screws to housing through panel slots as shown. Repeat panel installation to complete run.
Secure grid clips to t-bar ceiling using screws (by others).
Panel Installation
21
Variable End Installation
25
Oponal
For variable ends at a wall, insert variable panel inside installed grid panel. Slide to required posi­tion. NOTE: When installed, the variable panel will match the length of variable endplate installed in steps 14b-16 .
Oponal
Variable Panel Installation
22
Wall
(not shown for clarity)
Variable End Installation
26
Variable Panel Installation
23
Wall
(not shown for clarity)
Secure variable panel to housing with screw provided.
Variable Panel Installation
27
Oponal
Variable Panel Installation
24
Oponal
For variable ends on-grid, insert variable panel inside installed grid panel.
Finishing
28
Ensure all fixtures are level and in line
with each other.
Check that all joint and endplate screws
are installed and all seams are tight.
Check that all panel screws are attached
and tight.
Install grid clip to on-grid end cap by following instructions shown in step 18.
ATTENTION: Install in accordance with national and local building and electrical codes.
!
Attach on-grid endplate by securing grid clip to t-bar. Secure grid clip to t-bar following instructions shown in step 21.
Slide variable panel against t-bar and secure to housing with screw provided.
Loading...