Philips LC4043 Service Manual

1-1 LC4043
1. Safety guidelines
IMPORTANT SAFETY NOTICE
Portable LCD projector
Proper service and repair is important to the safe, reliable operation of all Philips Consumer Electronics Company** Equipment. The service procedures recommended by Philips and described in this service manual are effective methods of performing service operations. Some of these service operations require the use of tools specially designed for the purpose. The special tools should be used when and as recommended.
It is important to note that this manual contains various CAUTIONS and NOTICES which should be carefully read in order to minimize the risk of personal injury to service personnel. The possibility exists that improper service methods may damage the equipment. It also is important to understand that these CAUTIONS and NOTICES ARE NOT EXHAUSTIVE. Philips could not possibly know, evaluate and advise the service trade of all conceivable ways in which service might be done or of the possible hazardous consequences of each way. Consequently, Philips has not undertaken any such broad evaluation. Accordingly, a servicer who uses a service procedure or tool which is not recommended by Philips must first satisfy himself thoroughly that neither his safety nor the safe operation of the equipment will be jeopardized by the service method selected.
** Hereafter throughout this manual, Philips Consumer Electronics Company will be referred to as Philips.
WARNING
Critical components having special safety characteristics are identified with an!by the Ref. No. in the parts list and enclosed within a broken line* (where several critical components are grouped in one area) along with the safety symbol
Use of substitute replacement parts which do not have the same specified safety characteristics may create shock, fire, or other hazards.
Under no circumstances should the original design be modified or altered without written permission from Philips. Philips assumes no liability, express or implied, arising out of any unauthorized modification of design. Servicer assumes all liability.
* Broken Line
on the schematics or exploded views.
!
LC4043/17/40
Hopper XG20
Contents Page
1. Safety guidelines 1-1
2. Specifications 2-1
3. Warnings & Notes 3-1
4. Mechanical instructions 4-1
5. Block diagrams, Wiring diagram & Oscillograms 5-1
6. Diagrams & PWB layouts 6-1
7. Directions for use 7-1
8. Alignments 8-1
9. Parts lists 9-1
PCS 92 688 GB
Published by Consumer Electronics Printed in The Netherlands©Copyright reserved Subject to modification
PCS 92 687 GB
g 3122 435 40160
2. Specifications
LC4043 LC4043
2-1 3-1
3. Warnings & Notes
Technical specifications
LCD
Brightness Contrast Lamp
Lens
Specifications
Dimensions : 315 x 109 x 254 mm (WxHxD); 9 dm
Weight Nett. : 5,5 kg /ca 12 lbs. Package : Hopper XG20
Model
3x 0.9" HT Poly Silicon Active Matrix
:
2,359,296 pixels, RGB stripe
:
1000 ANSI Lumen
:
200:1 (Black/White)
:
UHP 120 compact; End user
:
replaceable, up to 4000 hours F1.8 - 2.2; f= 38-50 mm
:
Manual zoom x1.3; Manual focus
:
Projection distance 1.1 - 11 m;
:
Diagonal (44-440)” Longest life and “virtually” constant
:
light output over entire lamp life projection lamp Philips LIMESCO
:
matic Multi Scan data input handling, VGA up to SXGA resolutions to full screen (Frame Buffer) Intuitive graphic user interface for
:
ease of use Full PC control via ergonomic trackball
:
RC unit Fully Plug and Play compatible
:
(DDC 1/2b) Line doubling technology for perfect
:
video
performance : Low noise ventilation : Ceiling mount (Full Mirror) / Standby
:3
: Lens-cap : VGA cable (2m) + programmable MAC
adapter :
Mouse cable set (2m, 8 pin Mini DIN to
RS232; 2m, 8 pin Mini DIN to 4 pin
Mini DIN Apple MAC (ADB)) :
Audio Video Cinch Cable
(2m, Video/Audio stereo) :
Scart adapter; scart to RCA video and
stereo audio :
Power cord (3m) :
Remote control + 3x AA batteries +
mouse driver floppies :
Projector Carrying Bag :
DFU (8 languages) :
LC 4043/40
LC 4043/17
TM
inside for full auto-
Input/Output Capability
INPUT SIGNALS
Video Data
Power In
INPUT CONNECTIONS
Video
Data
Mains
OUTPUT CONNECTIONS
Audio
NTSC 3.58, 4.43/PAL-BG, N, M/Secam
:
PC and MAC compatible, Multi scan
:
VGA, SVGA, XGA, SXGA via LIMESCO full screen S VGA display (Frame Buffer); Auto Identification; Hor. scan rate up to 90 kHz; Vert. refresh rate up to 85 Hz. 120-240 V(Full range); 50/60 Hz;
:
160 W
S-Video (Y/C DIN);Video (Cinch);
:
Stereo Audio (2x Cinch) Mini sub-D data (15 pin)/PC,
:
Stereo Audio (M3,5 stereo jack) / Serial mouse (RS232 and ADB) Mains input socket (3 pin)
:
Stereo Audio (M3,5 stereo jack)
:
Special features
1000 Ansi Lumen
Quiet - a quarter of the noise of current projectors
• (Sound Pressure Level 33 decibels)
Manual zoom / focus
Ceiling mountable
Auto Voltage - automatic worldwide compatibility
Best picture performance - 1000 Ansi Lumen, longest brightness over time, 85% picture homogeneity
Philips LIMESCO inside for full automatic Multi Scan data input handling, VGA up to SXGA resolutions without information loss.
Philips UHP Lamp; 120W up to 4000 hours, lamp life with ”virtually” constant light output for a perfect picture quality
Philips Total Assurance:
-
reliability
-
robust design
-
free technical support. (toll-free)
TM
(LIne MEmory Scan COnverter)
Warnings
1.
Safety regulations require that the unit should be returned in its original condition and that components identical to the original components are used. The safety components are indicated by the symbol
!.
2. ESD
All ICs and many other semiconductors are sensitive to electrostatic discharges (ESD). Careless handling during repair can drastically shorten the life. Make sure that during repair you are connected by a pulse band with resistance to the same potential as the earth of the unit. Keep components and tools also at this same potential.
3. When repairing a unit, always connect it to the mains voltage
via an isolating transformer. The lamp supply and the lamp housing are not mains isolated.
4. Be careful when taking measurements in the high-voltage
section.
5. Never replace modules or other components while the unit is
switched on.
6. When making settings, use plastic rather than metal tools.
This will prevent any short circuits and the danger of a circuit becoming unstable.
7. After repair the wiring should be fastened once more in the
cable clamps for this purpose.
8. In order to prevent measuring errors, the heat sinks should
not be used as reference points for measurements.
9. The Lamp house and the lamp get hot during operation.
Please ensure that they are cooled down before servicing.
10. The lighthouse (optical part) is extremely sensitive to dust.
This part should only be opened in a dust-free environment (class 100 according to the US federal standard 209).
Notes
1.
The direct voltages and oscillograms should be measured with regard to earth (4), or hot earth (
) as this is called.
5
2. The direct voltages and oscillograms shown in the diagrams
should be measured:
For testpoints Txxxx VIDE;
• using a video colour bar. For testpoints Txxxx DATA;
• using a data greyscale. For testpoints Txxxx DRB;
• using an internal greyscale. For testpoints Txxxx AUD;
• using an audio signal of 1 kHz.
3. The semiconductors indicated in the circuit diagram and in the
parts lists are completely interchangeable per position with the semiconductors in the unit, irrespective of the type indication on these semiconductors.
PCS 92 689 GB PCS 92 690 GB