1 Align the brush head so the bristles point in the
same direction as the front of the handle.
2 Firmly press the brush head down onto the
metal shaft until it stops.
English
7
Note: Philips Sonicare brush heads are imprinted
with icons to easily identify your brush head.
English
8
Charging your Philips Sonicare
1 Plug the charger into an electrical outlet.
2 Place the handle on the charger.
-The ashing light of the battery level
indicator indicates that the toothbrush is
charging.
-When the battery is fully charged, the
battery level indicator lights up solid green
for 10 seconds before it turns o.
Note: It can take up to 48 hours to fully charge
the battery, but the Philips Sonicare may be used
before it is fully charged.
Battery status (when handle is not on charger)
- A ashing yellow battery level indicator
indicates a low charge.
- A ashing green battery level indicator indicates
a moderate charge.
- A solid green battery level indicator indicates a
full charge.
Note: If you hear 5 beeps and the battery level
indicator ashes yellow, this means that you have to
recharge the battery. When the battery is completely
empty, the Philips Sonicare turns o. Place the Philips
Sonicare on the charger to charge it.
To keep the battery fully charged at all times,
you may keep your Sonicare on the charger when
not in use.
Using your Philips Sonicare
Brushing instructions
1 Wet the bristles and apply a small amount of
toothpaste.
2 Place the toothbrush bristles against the teeth
at a slight angle (45 degrees), pressing rmly to
make the bristles reach the gumline or slightly
beneath the gumline.
Note: Keep the center of the brush in contact
with the teeth at all times.
3 Press the power on/o and mode button to
turn on the Philips Sonicare.
4 Apply light pressure to maximize Philips
Sonicare’s eectiveness and let the Philips
Sonicare toothbrush do the brushing for you.
Do not scrub.
5 Gently move the brush head slowly across
the teeth in a small back and forth motion so
the longer bristles reach between your teeth.
Continue this motion throughout the brushing
cycle.
6 To clean the inside surfaces of the front teeth,
tilt the brush handle semi-upright and make
several vertical overlapping brushing strokes on
each tooth.
Note: To make sure you brush evenly
throughout the mouth, divide your mouth into
4 sections using the Quadpacer feature (see
chapter ‘Features’).
English
9
10
English
1
2
7 Begin brushing in section 1 (outside upper
teeth) and brush for 30 seconds before
you move to section 2 (inside upper teeth).
4
3
Continue brushing in section 3 (outside lower
teeth) and brush for 30 seconds before you
move to section 4 (inside lower teeth).
Note: When using the White mode, two
additional 15 second intervals can be used for
polishing your front teeth.
8 After you have completed the brushing cycle,
you can spend additional time brushing the
chewing surfaces of your teeth and areas
where staining occurs. You can also brush your
tongue, with the toothbrush turned on or o,
as you prefer.
Your Philips Sonicare is safe to use on:
- Braces (brush heads wear out sooner when
used on braces).
- Dental restorations (llings, crowns, veneers).
Note: Ensure that braces or dental restorations are
properly adhered and not compromised. If not,
braces or dental restorations may be damaged when
they come into contact with the brush head.
Note: When the Philips Sonicare is used in clinical
studies, the default 2-minute Clean mode with high
intensity must be selected. The handle should be
fully charged and the Easy-start feature deactivated.
Brushing modes
Intensity levels
English
11
Clean mode
The ultimate in plaque removal (default mode).
Clean mode lasts for 2 minutes and includes four
30 second Quadpacer intervals.
White mode
To brighten and polish your front teeth.
White mode lasts for 2.5 minutes and includes four
30 second Quadpacer intervals and two and two
additional 15 second Quadpacer intervals to focus
on your visible front teeth.
1 Press the power on/o and mode button to
turn on your Philips Sonicare.
2 Press the power on/o and mode button again
within 2.5 seconds to switch to White mode.
3 Press the power on/o and mode button after
2.5 seconds to pause your Philips Sonicare.
- Low: 1 LED indicator light
- Medium: 2 LED indicator lights
- High: 3 LED indicator lights
Note: To adjust the intensity level to the next
higher or lower level, press the + intensity level
button to increase intensity or the - intensity level
button to decrease intensity at any time during the
brushing cycle
English
12
Features
Smartimer
Easy-start
The Smartimer indicates that your brushing cycle
is complete by automatically turning o the
toothbrush at the end of the brushing cycle.
Dental professionals recommend brushing no less
than 2 minutes twice a day.
The Easy-start feature gently increases the power
over the rst 14 brushings to help you get used to
the brushing with the Philips Sonicare.
This Philips Sonicare comes with the Easy-start
feature deactivated.
Activating or deactivating the Easy-start
feature
1 Attach the brush head to the handle.
2 Place the handle in the plugged-in charger.
To activate Easy-start:
Press and hold the power on/o and mode button
for 2 seconds. You hear 2 beeps and the battery
level indicator lights up green to indicate that the
Easy-start feature has been activated.
To deactivate Easy-start:
Press and hold the power on/o and mode button
for 2 seconds. You hear 1 beep and the battery
level indicator lights up yellow to indicate that the
Easy-start feature has been deactivated.
Note: Using the Easy-start feature beyond the
initial ramp-up period is not recommended and
reduces Philips Sonicare eectiveness in removing
plaque.
Quadpacer
1
2
4
3
The Quadpacer is an interval timer that has a short
beep and pause to remind you to brush the
4 sections of your mouth evenly and thoroughly.
Depending on the brushing mode you have
selected, the Quadpacer beeps at dierent
intervals during the brushing cycle. See the
"brushing modes" section for more details.
Activating or deactivating the Quadpacer
feature:
Place the handle in the plugged-in charger.
- To activate Quadpacer:
Press and hold the intensity level button
down (-) for 2 seconds. You hear 2 beeps and
the battery level indicator lights up green to
indicate that the Quadpacer feature has been
activated.
- To deactivate Quadpacer:
Press and hold the intensity level button
down (-) for 2 seconds. You hear 1 beep and
the battery level indicator lights up yellow to
indicate that the Quadpacer feature has been
deactivated.
Charger conrmation
When the charger conrmation feature is activated,
the handle beeps and vibrates briey when it is
placed on the charger base. This Philips Sonicare
model comes with the charger conrmation
feature deactivated.
Activating or deactivating the charger
conrmation feature:
Place the handle on the charger.
- To activate charger conrmation:
English
13
English
14
Press and hold the intensity level button up (+) for
2 seconds. You hear 2 beeps and the battery level
indicator lights up green twice to indicate that the
charger conrmation feature has been activated.
- To deactivate charger conrmation:
Press and hold the intensity level button up (+) for
2 seconds. You hear 1 beep and the battery level
indicator lights up yellow once to indicate that the
charger conrmation feature has been deactivated.
Cleaning
Toothbrush handle
1 Remove the brush head and rinse the metal
shaft area with warm water. Make sure you
remove any residual toothpaste.
Caution: Do not push on the rubber seal on the
metal shaft with sharp objects, as this may cause
damage.
2 Wipe the entire surface of the handle with a
Brush head
1 Rinse the brush head and bristles after each
use.
2 Remove the brush head from the handle and
damp cloth.
rinse the brush head connection with warm
water at least once a week.
Charger
C
Y
C
1
.
8
2
2
7
Storage
Replacement
Brush head
Disposal
L
E
E
R
A B A C
.
8
0
0
3
8
8
.
English
1 Unplug the charger before you clean it.
2 Wipe the surface of the charger with a damp
cloth. Make sure you remove any toothpaste or
other residue from the charger surfaces.
If you are not going to use the Sonicare for an
extended period of time, unplug the charger from
the electrical outlet, clean it and store it in a cool
and dry place away from direct sunlight.
Replace Philips Sonicare brush heads every
3 months to achieve optimal results. Use only
Philips Sonicare replacement brush heads.
This appliance contains a rechargeable battery
which must be disposed of properly. Contact your
local town or city ocials for battery disposal
information. You can also call 1-800-8-BATTERY
or visit www.rbrc.com for battery drop-o
locations.
For assistance, visit our website www.philips.com/
support or call 1-800-243-3050 toll free.
15
English
16
Removing the rechargeable battery
Warning: Only remove the rechargeable battery
when you discard the appliance. Make sure the
battery is completely empty when you remove it.
To remove the rechargeable battery, you need
a towel or cloth, a hammer and a at-head
(standard) screwdriver. Observe basic safety
precautions when you follow the procedure
outlined below. Be sure to protect your eyes,
hands, ngers, and the surface on which you work.
1 To deplete the rechargeable battery of any
charge, remove the handle from the charger,
turn on the Philips Sonicare and let it run until it
stops. Repeat this step until you can no longer
turn on the Philips Sonicare.
2 Remove and discard the brush head. Cover the
entire handle with a towel or cloth.
3 Hold the top of the handle with one hand and
strike the handle housing 0.5 inch above the
bottom end. Strike rmly with a hammer on all
4 sides to eject the end cap.
Note: You may have to hit on the end several
times to break the internal snap connections.
4 Remove the end cap from the toothbrush
handle. If the end cap does not release easily
from the housing, repeat step 3 until the end
cap is released.
English
5 Holding the handle upside down, press the
shaft down on a hard surface. If the internal
components do not easily release from
the housing, repeat step 3 until the internal
components are released.
6 Remove the rubber battery cover.
7 Wedge the screwdriver between the battery
and the black frame at the bottom of the
internal components. Then pry the screwdriver
away from the battery to break the bottom of
the black frame.
8 Insert the screwdriver between the bottom of
the battery and the black frame to break the
metal tab connecting the battery to the green
printed circuit board. This will release the
bottom end of the battery from the frame.
17
Loading...
+ 39 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.