Introduction

Congratulations on your purchase and welcome to Philips! To fully benefit from the support that Philips offers, register your product at www.philips.com/welcome.
Use AirFloss with your favorite mouthwash as part of your oral care routine. In addition to brushing, AirFloss helps reduce the plaque in between teeth in order to improve your gum health.

Important

Read this user manual carefully before you use the appliance and save it for future reference.

Danger

- Keep the charger away from water. Do not place or store it over or near water contained in a bathtub, washbasin, sink etc. Do not immerse the charger in water or any other liquid. After cleaning, make sure the charger is completely dry before you connect it to the mains.

Warning

- The mains cord cannot be replaced. If the mains cord is damaged, discard the charger.
- Always have the charger replaced with one of the original type in order to avoid a hazard.
- Do not use the charger outdoors or near heated surfaces.
- If the appliance is damaged in any way (brush head, toothbrush handle or charger), stop using it. This appliance contains no serviceable parts. If the appliance is damaged, contact the Consumer Care Center in your country (see chapter 'Warranty and support').
English
English
- This appliance can be used by children aged from 8 years and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and if they understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children unless they are older than 8 and supervised.

Caution

- Do not clean the brush head, the handle or the charger in the dishwasher.
- If you have had oral or gum surgery in the previous 2 months, consult your dentist before you use the toothbrush.
- Consult your dentist if excessive bleeding occurs after using this toothbrush or if bleeding continues to occur after 1 week of use. Also consult your dentist if you experience discomfort or pain when you use the Philips Sonicare.
- The Philips Sonicare toothbrush complies with the safety standards for electromagnetic devices. If you have a pacemaker or other implanted device, contact your physician or the device manufacturer of the implanted device prior to use.
- If you have medical concerns, consult your doctor before you use the Philips Sonicare.
- This appliance has only been designed for cleaning teeth, gums and tongue. Do not use it for any other purpose. Stop using the appliance and contact your doctor if you experience any discomfort or pain.
- The Philips Sonicare toothbrush is a personal care device and is not intended for use on multiple patients in a dental practice or institution.
- Stop using a brush head with crushed or bent bristles. Replace the brush head every 3 months or sooner if signs of wear appear. Do not use other brush heads than the ones recommended by the manufacturer.
7
English
8
- If your toothpaste contains peroxide, baking soda or bicarbonate (common in whitening toothpastes), thoroughly clean the brush head with soap and water after each use. This prevents possible cracking of the plastic.

Electromagnetic fields (EMF)

This Philips appliance complies with all applicable standards and regulations regarding exposure to electromagnetic fields.

Your Philips AirFloss Ultra (Fig. 1)

1 Nozzle tip 2 AirFloss Ultra nozzle 3 Activation button 4 Reservoir and reservoir door 5 Handle 6 Charge & burst mode indicators
- Single burst: 1 LED
- Double burst: 2 LEDs
- Triple burst: 3 LEDs
7 Power/mode button 8 Removable nozzle holder (select models) 9 Charger
Note: The contents of the box may very based on the model purchased.

Charging

Charge the AirFloss Ultra for 24 hours before first use.
1 Put the plug of the charger in the electrical outlet.
2 Place the handle on the charger (Fig. 2).
Charging process: (Fig. 3)
- 1 green LED: 33% charged.
- 2 green LEDs: 66% charged.
- 3 green LEDs: 100% charged.
English
Note: When it is fully charged, AirFloss Ultra has an operating time of up to 11 days when it is used in triple burst mode, and up to 33 days when it is used in single burst mode.
Note: When the charge indicators flash yellow, the battery is low and needs to be recharged (fewer than 3 uses left).

Preparing for use

1 Align the nozzle and press the nozzle down onto the handle
(‘click’) (Fig. 4). Note: We advise you to place the tip facing the front of the handle
as the illustration shows, but the nozzle can be placed in the handle either way without affecting the function. You can try both options and use what works best for you in your oral care routine.
Note: Replace the nozzle (HX8032, HX8033) every 6 months for optimal results. Also replace the nozzle if it becomes loose or no longer ‘clicks’ onto the handle.
Note: The AirFloss Ultra only supports AirFloss Ultra nozzles. Do not attempt to use non-AirFloss Ultra nozzles on the AirFloss Ultra handle.
2 Open the cover of the reservoir (‘click’) (Fig. 5). 3 Fill the reservoir with mouthwash or water. (Fig. 6)
Tip: For the best result and a fresher experience, we advise you to use mouthwash with your AirFloss Ultra.
Note: Do not use mouthwash that contains isopropyl myristate (e.g. Dentyl Active) or high concentrations of essential oils, as it may damage the appliance. This includes all mouthwash sold in glass and ceramic packaging.
4 Close the cover of the reservoir by pressing (‘click’) (Fig. 7). 5 Press the power/mode button to switch on the appliance. (Fig. 8)
The LEDs illuminate.
6 Press and hold the activation button until spray comes out of the
tip of the nozzle. (Fig. 9)
9
English
10

Using the appliance

1 Make sure the AirFloss Ultra is switched on. If it is off, press and
release the power/mode button to switch on the appliance. (Fig.
8)
You can change the modes to have the desired amounts of bursts each time you press the activation button (Fig. 9). For optimal results, use the triple burst mode (the default setting) from both the outside and inside of your teeth.
To change modes, press the power/mode button to cycle through the modes until you reach your desired mode. The LEDs show the selected mode:
- Single burst: 1 LED (Fig. 10)
- Double burst: 2 LEDs (Fig. 11)
- Triple burst: 3 LEDs (Fig. 12) Note: The AirFloss Ultra remembers what mode was selected last
and it is ready for the next use. If your AirFloss Ultra becomes fully drained of power, it will go back to the triple burst default mode once it has been recharged.
2 Place the nozzle tip between two teeth at your gum line. Slightly
close your lips over the nozzle when it is in place, to avoid splashing. (Fig. 13)
3 Press the activation button to deliver 1-3 bursts (depending on the
selected mode) of air and micro-droplets of mouthwash or water between the teeth. (Fig. 14)
4 Slide the nozzle tip along the gum line until you feel it settle
between the next two teeth.
5 Continue this procedure for all spaces between your teeth,
including behind your back teeth. (Fig. 15) Note: Refill the reservoir as needed.

Auto-burst function

Hold the activation button to deliver bursts continuously, approximately one second between set of bursts.
English

Automatic shut-off function

The AirFloss automatically turns off if it has not been used for one minute.

Cleaning

If the AirFloss Ultra becomes clogged, or to clean the inside of the AirFloss, fill the reservoir with warm water and press the activation button until the reservoir is empty.
Do not clean the nozzle, handle or charger in the dishwasher.
Do not use cleaning agents to clean the appliance. The formulation or strength of some agents may damage the appliance.

Handle and nozzle

1 Remove the AirFloss Ultra nozzle from the handle. Rinse the
nozzle after each use to eliminate the residue left in it. (Fig. 16)
2 Open the reservoir and rinse it under a faucet to eliminate residue.
(Fig. 17) Tip: You can also use a cotton swab to wipe the reservoir and
remove the remaining residue.
Note: Do not immerse the handle in water.
Note: Failure to remove residue from the nozzle or reservoir may result in an unhygienic condition.
3 Wipe the entire surface of the handle with a damp cloth. (Fig. 18)

Charger

1 Unplug the charger before you clean it. 2 Wipe the surface of the charger with a damp cloth.
11

Storage

If you are not going to use AirFloss Ultra for an extended period of time, follow the steps below.
1 Open the cover of the reservoir and empty it. 2 Press the activation button until no more spray comes out of the
nozzle.
3 Unplug the charger.
English
12
4 Clean AirFloss Ultra nozzle, handle and charger. Refer to chapter
‘Cleaning’.
5 Store AirFloss Ultra in a cool, dry place away from direct sunlight.

Recycling

- Do not throw away the product with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. By doing this, you help to preserve the environment.
- This product contains a built-in rechargeable battery which shall not be disposed of with normal household waste. We strongly advise you to take your product to an official collection point or a Philips service centre to have a professional remove the rechargeable battery.
- Follow your country’s rules for the separate collection of electrical and electronic products and rechargeable batteries. Correct disposal helps prevent negative consequences for the environment and human health.
Please note that this process is not reversible.
1 To deplete the battery, repeatedly press the activation button until
the AirFloss no longer produces any bursts of air. (Fig. 20)
2 Remove the AirFloss nozzle from the handle. (Fig. 21) 3 Firmly grab the handle with one hand at the top and one hand on
the bottom. (Fig. 22)
4 Snap the handle into two parts. (Fig. 23)
Note: This step requires a good amount of physical force. The top and bottom half of the handle should be separated once you snap the handle.
5 Remove the bottom half of the handle. (Fig. 24) 6 Cut all 6 wires on the internal component with scissors. (Fig. 25) 7 Completely pull apart the internal component from the top part of
the handle. (Fig. 26)
8 The battery is located inside the top half of the handle. Remove
the battery and dispose of it properly (not in household waste). (Fig. 27)
Loading...