IMPORTANT
SAFEGUARDS
READ ALL INSTRUCTIONS BEFORE USE
DANGERS
To reduce the risk of electrocution:
-Do not place or store product where it can fall or be pulled
into a bathtub, washbasin or sink.
-Do not place charger in or drop into water or other liquid,
unplug the charger immediately if this should occur.
-After cleaning, make sure the charger is completely dry before
you connect it to the mains.
WARNINGS
To reduce the risk of burns, electrocution, re, or physical injury:
-DO NOT use alcohol or other cleaning uids in the reservoir
as it may be an ingestion hazard.
-DO NOT use attachments other than those recommended by
the manufacturer.
-DO NOT plug the charger into an outlet with a voltage other
than specied on the bottom of the charger. This product is
designed to operate within a range of 100 to 240 volts. Voltage
converters DO NOT warrant voltage compatibility.
-DO NOT use hot water so as to avoid physical injury.
-DO NOT use the charger outdoors.
-DO NOT drop or insert any foreign objects into the reservoir.
-Never force the plug into an outlet; if the plug does not easily
t into the outlet, discontinue use.
-Keep the cord away from heated surfaces.
-Discontinue use if the nozzle, body, or charger body/cord
appear damaged in any way. Refer to “Warranty and Service”
for service or repair.
5
-This product contains no user-serviceable parts. Refer to
“Warranty and Service” if AirFloss no longer works properly
or needs repair.
-Use this product only for its intended use as described in this
document or as recommended by your dental professional.
-This product is not intended for use by persons (including
children) with reduced physical, sensory, or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
-Children should be supervised to ensure that they do not play
with the appliance.
-AirFloss is a personal care device and is not intended for use on
multiple patients in a dental ofce or institution.
-Do not direct the spray under the tongue or into the ear, nose,
eye, or other sensitive areas. This product may cause serious
damage to these areas. See “Using AirFloss” for correct usage.
-Avoid applying excessive nozzle tip pressure.
6
MEDICAL WARNINGS
-Consult your dental professional before you use this product
if you have had oral or gum surgery in the previous two (2)
months.
-Contact your dental professional if excessive bleeding occurs
after using this product or bleeding continues to occur after
one (1) week of use.
-Discontinue use of this product and contact a physician/dentist
if discomfort or pain is experienced.
-This product complies with the safety standards for
electromagnetic devices. If you have a pacemaker or other
implanted device, contact your physician or the device
manufacturer prior to use.
-Consult your physician if you have other medical concerns.
Electromagnetic elds (EMF)
This Philips product has been tested and is compliant with safety
standards for electromagnetic devices. If handled properly and
according to the instructions in this user manual, the product is safe
to use.
SAVE THESE
INSTRUCTIONS
7
2
A Guidance tip
B AirFloss nozzle
C Activation button
D Water reservoir and cover
E Handle
8
F Charge indicator
G Power on/off button
H Removable charger cover
(select models)
I Charger
CHARGING AIRFLOSS
3
Charge for 24 hours before rst use . Charge indicator ashes green until AirFloss
is fully charged. Rapid yellow ashing indicates charge is extremely low (fewer
than 3 uses left). AirFloss is designed to last 2 weeks (or 14 uses) on a single
charge.
9
PREPARING FOR USE
4
To use, attach nozzle, ll reservoir with water or mouthwash. After lling the
reservoir, press the power on/off button to turn on, then press the activation
button approximately 6 times or until spray is produced. The reservoir holds
enough liquid for approximately 2 uses. Replace the nozzle every 6 months for
optimal results.
10
USING AIRFLOSS
5
AirFloss is designed to be used on the outside of the teeth. Place the tip between
teeth and apply gentle pressure. Press activation button to deliver a burst of
air and water. Glide the guidance tip along the gum line until you feel it settle
between the next two teeth. Press the activation button again and repeat for
all spaces including behind your back teeth. Press power on/off button to turn
power off after use.
11
6
AUTO OFF
12
CLEANING AIRFLOSS
7
Remove nozzle and rinse reservoir with water. Use a cotton-tipped swab to
wipe down the reservoir, if desired. Avoid getting foreign objects inside. The use
of cleaning agents inside the device is not recommended. Do not clean in the
dishwasher or any other sanitizing devices.
13
STORING AIRFLOSS
8
If AirFloss will not be used for an extended period of time, empty water from
reservoir, press activation button until no spray is produced, unplug the charger,
clean the product, and store it in a cool, dry place away from direct sunlight.
14
DISPOSING OR RECYCLING AT END OF PRODUCT LIFE
9
Please note this process is not reversible - The rechargeable battery inside
AirFloss cannot be replaced but can be removed for recycling. Please contact
your local waste management for recycling requirements. Only remove the
battery at the end of the product’s life. Doing so earlier will destroy the product.
Deplete the battery charge by repeatedly pressing the activation button until
AirFloss no longer produces any bursts of air. Observe basic safety precautions.