Philips HX 1510 Service Manual

Tooth brush
HX 1510
Philips Domestic Appliances and Personal Care
Service Manual 4322 277 00530 herewith cancels
Service Manual
PRODUCT INFORMATION
- Gum Protection System : The brush automatically fl exes back when too much pressure is applied. Because of this signal, the user will develop a safe and effi cient brushing technique.
- Active tip : Removes plaque between the teeth
- Number of brush heads included in fancy box : 1
- Colours : White/ orange
- Waterproof : Yes
- Anti rolling strip : To prevent the appliance from rolling away
TECHNICAL DATA
Voltage : 110-127 V; 200-240 V, 50-60 Hz Power consumption : 2.8 Watts Speed (top) : up to 15.000 brush strokes
per minute Gum Protection System click at : 270 gr. Charging time (empty to full) : 16 hours Operating time (full to empty) : ± 25 minutes Battery type : NiCd
Product meets the requirements regarding
interference suppression on radio and TV.
@ = changed
SERVICE INFORMATION
Hand unit tooth brush (1)
Never open the hand unit of the toothbrush because the unit is no longer watertight after it has been opened. Replace the entire unit in case of a defect.
For standardisation reasons, the hand unit of the HX 1510 is replaced by the hand unit of the HX 1511. Colours: White/ green @
When discarding the hand unit, remove the built-in rechargeable battery. The battery should be completely empty. For instructions p.t.o.
Charging unit (2)
In case of a defective charging unit or damaged cord the complete charging unit must be replaced.
Charging tips
· The appliance will only charge if the appliance is switched off.
· Please note that the electricity supply to sockets in mirror
cabinets over washbasins or shaver sockets in bathrooms may be cut off when the light is switched off.
· The toothbrush can be put back in the stand after use and left to charge continuously. However, to extend the lifetime of the battery proceed as follows: When the appliance is used for the fi rst time, continue to use it until the battery is empty. Use the appliance in the normal way without recharging it between the brushing sessions. Recharge the appliance when the motor almost stops running. Repeat this procedure 3 times in a row every 6 months.
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
4322 277 00971 02/06
DISASSEMBLY ADVICE + EXPLODED VIEW + PARTS LIST HX 1510
INSTRUCTIONS
TO REMOVE
THE BATTERY
Pick up the charging unit and place the toothbrush on the pin. Turn the toothbrush anti­clockwise to unscrew the bottom of the toothbrush.
2
1
Turn the toothbrush upside down and press it down on a hard surface to remove the battery holder.
1
3
Open the lid of the battery holder by means of a screwdriver.
Lift the battery out of the battery holder by means of a screwdriver.
Pos Description
Hand unit (NiCd) @
1
Stand 220 - 240 V, EURO plug
2
Stand 220 - 240 V, UK plug Stand 220 V, Argentina Stand 220 - 240 V, Australia Stand 220 V, Korea Stand 110 - 127 V, Taiwan
Brush head (2-pack) @
3
2
Service code
4203 035 75440
4203 035 75490 4203 035 75500 4203 035 75510 4203 035 75520 4203 035 75530 4203 035 75540
8812 012 40020
After the bottom has been unscrewed, the appliance may not be watertight anymore and the guarantee will become invalid.
@ = changed