Philips HU4802 User Manual [ru]

Always there to help you
Question?
Contact
Philips
Register your product and get support at www.philips.com/welcome
User manual 3
Қолданушының нұсқасы 26
Руководство пользователя 49
Contents
1 Important 4
Safety 4
2 Your humidier 7
What's in the box 7
3 Getting started 8
Prepare for humidication 8
4 Using the humidier 9
Understand the humidity indication 9 Understand the healthy air protect
alert and lock 9 Switch the humidier on and off 10 Change the fan speed 11
Auto 11 Manual 11
Sleep mode 11 Set the timer 12 Set the humidity level 12 Water level 13 Rell water 13
10 Notices 25
Electromagnetic elds (EMF) 25
Compliance with EMF 25
Recycling 25
English
5 Clean your humidier 15
Clean the body of the humidier 15 Clean the water tank 15
6 Clean the humidication lter 16
7 Replacing the lters 18
Replace the humidication lter 18 Replace the anti-bacterial lter 20
8 Troubleshooting 22
9 Guarantee and service 24
Order parts or accessories 24
3EN
1 Important
Safety
Read this user manual carefully before you use the humidier, and save it for future reference.
Danger
Do not spray any ammable
materials such as insecticides or fragrance around the humidier.
The water in the water tank
is not suitable for drinking. Do not drink this water and do
not use it to feed animals or to
water plants. When you empty the water tank, pour the water down the drain.
Do not use the humidier if the
plug, the power cord, or the humidier itself is damaged.
This humidier is not intended
for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have
been given supervision or
instruction concerning use of the humidier by a person responsible for their safety.
This appliance is not a toy.
Children should be supervised to ensure that they do not play
with the humidier.
Do not block the air inlet and
outlet, e.g. by placing items on
the air outlet or in front of the
air inlet.
Warning
Check if the voltage indicated
on the bottom of the humidier corresponds to the local power voltage before you connect the humidier.
If the power cord is damaged,
you must have it replaced by Philips, a service center authorized by Philips, or similarly qualied persons in order to avoid a hazard.
4 EN
Caution
If the power socket used to
power the humidier has poor connections, the plug of the humidier becomes hot. Make sure that you plug the humidier into a properly connected power socket.
Always place and use the
humidier on a dry, stable, level, and horizontal surface.
Do not place anything on top of
the humidier and do not sit on the humidier.
Make sure that the humidier is
well assembled/connected every time after you clean it or after you remove the upper cover and/or water tank for relling. The humidier must be properly
assembled to deliver a good and
safe performance.
Only use the original Philips
lter specially intended for this humidier. Do not use any other lter.
Avoid knocking against the
humidier (the air inlet and outlet in particular) with hard objects.
Do not insert your ngers or
objects into the air outlet or the air inlet to prevent physical injury or malfunctioning of the humidier.
Do not use this humidier when
you have used indoor smoke­type insect repellents or in places with oily residues, burning incense, or chemical fumes.
Do not use the humidier near
gas appliances, heating devices or replaces.
Always unplug the humidier
after use and before you clean it.
Do not ll water from the air
outlets on top of the humidier.
Place the humidier properly to
prevent children from knocking it over.
Do not use the humidier in a
room with major temperature
changes, as this may cause condensation inside the humidier.
When the humidier is not used
for a long time, bacteria and mold may grow on the lters. Check the lters before you start using the humidier again. If the lter is very dirty with dark spots, replace it (see chapter ‘Replacing the humidication lter’).
Do not wash the lter in a
washing machine or dish washer, otherwise the lter will be deformed.
The humidier is only intended
for household use under normal
operating conditions.
Clean the water tank and
humidication lter every week to keep it clean.
Only ll the water tank with cold
tap water. Do not use ground water or hot water.
English
5EN
Do not put any substance other
than water in the water tank. Do not add fragrance or chemical substance into the water. Use only water (tap, puried, mineral, any sort of potable water).
If you do not use the humidier
for a long time, clean the water tank and dry the humidication lter..
If you need to move the
humidier, disconnect the humidier from the power supply rst. Then empty the water tank, and carry the humidier horizontally.
Keep the humidity sensor dry.
If the sensor gets wet, it could miscalculate the humidity level, and the humidier could stop working due to miscalculated humidity level.
6 EN
2 Your humidifier
What's in the box
Congratulations on your purchase, and welcome to Philips! To fully benet from the support that Philips offers, register your product at www.philips.com/welcome. The Philips humidier brings fresh, humidied air to your house for the health of your family. It offers you advanced evaporation system with NanoCloud technology, using a special humidication lter which adds H2O molecules to the dry air, and produces healthy humid air without formation of water mist. Its humidication lter retains bacteria, calcium and other particles from the water. It delivers only pure humidied air in your home. No more
dry air in the winter season or from the air
conditioning. Read this user manual carefully before you install and use the humidier. Save it for future reference.
Check and identify the contents of your package:
Upper unit
Humidication lter (HU4102)
Filter support
Float
Anti-bacterial lter - HU4112 (only available for HU4803)
English
www.philips.com/welcome
User manual
User manual
www.philips.com/welcome
Quick start guide
Quick start guide
Water tank
www.philips.com/welcome
Warranty
Warranty
7EN
3 Getting started
MAX
Prepare for humidication
1
Hold by both sides of the upper unit to
lift it up.
2 Fill the water tank with cold tap water until
water reaches the maximum water level indication.
3 Place the upper unit back onto the water
tank.
8 EN
4 Using the
humidifier
Understand the humidity indication
The humidier is equipped with a built-in humidity sensor. For HU4802, you can set the target humidity level at 40%RH, 50%RH and 60%RH. The color of the humidity indicator light shows whether the set target is reached or not. For HU4803, the actual humidity level is displayed on the center of the control panel from 20%RH to 95%RH.
HU4802 HU4803
Note
A comfortable humidity level is from 40RH% to 60RH%.
The accuracy of the humidity indication is
approximately ±10%.
It takes some time to measure the humidity level in
the room.
Note
The humidity indicator light is only available on HU4802.
The humidier is equipped with built-in humidity sensor.
When the desired humidity level is reached, the color of the humidity indicator light is in blue. When the humidity level is not reached, the color of the humidity indicator light becomes red.
Understand the healthy air protect alert and lock
The healthy air protect alert gives you a timely warning when the water tank needs relling. When the water in the tank starts getting low, a red indicator to tell you that it is time to rell the tank. It blinks for 30 minutes. After that, the indicator remains on before the water tank is relled with water.
The healthy air protect lock always ensures that your humidier does not work without water in the tank. When the water tank is empty and needs to be relled, the healthy air protect lock shuts off the humidier after 30 minutes and a red indicator lights up. When you rell the water tank properly, the humidier is turned on again.
In sleep mode, the red indicator does not blink, it turns
on when the water level is low.
on the control panel starts blinking
Note
English
Color of the humidity indicator light (HU4802 only)
Blue target achieved
Red below target
The humidity indicator light automatically goes on when the humidier is switched on.
Humidity level
9EN
Switch the humidier on and
off
1
Plug the humidier into the power supply.
» For HU4803, the current humidity
level is shown.
» The current fan speed is shown.
2 Press the
humidier.
» For HU4802, the humidity indicator
button to switch on the
light is on.
3 Press the
Note
If the water level in the tank is getting very low, the
humidier stops humidifying. The red rst starts blinking and then remains on.
The humidier releases very ne invisible mist, so it is
normal that you cannot see the mist.
button to switch off the humidier.
indicator light
10 EN
Change the fan speed
Auto
Note
AUTO mode is only available for HU4803.
The automatic mode uses the digital sensor to constantly monitor the air humidity. It turns your humidier on and off whenever needed to ensure the humidity level is constantly at the right level. The default humidity level of the automatic mode is set at 50RH%, but you can change it to your desired humidity level under the automatic mode. Next time when you switch on the humidier, it will remember your last set humidity level, unless you have removed the plug from the wall socket. In this case the default humidity level is set at 50RH% again.
1 Press the SPEED button to select the
AUTO mode.
Manual
You can manually select the desired fan speed.
1 Press the SPEED button once or more
times to select the desired fan speed (AUTO,
Tip
AUTO and modes are only available for HU4803.
For HU4802 and non-auto modes of HU4803: if the
desired humidity level is reached, you can change to a lower fan speed. However, if the desired humidity level is not reached, you can select a higher fan speed to humidify the air quickly.
, or ).
Sleep mode
In sleep mode, the humidier operates quietly with dimmed light for your undisturbed sleep.
1 Press the SPEED button once or more
times to select sleep mode. In sleep mode,
only the speed
light is on.
English
Tip
If the desired humidity level is reached, the humidier
changes to a lower fan speed automatically.
In AU TO mode, the fan speed only varies between and .
2 To change to another fan speed, simply
press the SPEED button again.
11EN
Note
Sleep mode only works at speed .
In sleep mode, the red indicator does not blink, but
remains on when the water level gets low.
In sleep mode, you can only set the timer; the humidity
level cannot be set, and the humidity light is off.
Set the timer
With the timer function, you can let the humidier operate for a set number of hours. When the set time has elapsed, the humidier automatically switches off.
1 Press the TIMER button to activate the
timer.
» The TIMER light (1H, 4H or 8H) goes on.
2 Press the TIMER button repeatedly to
choose the number of hours you want the humidier to operate. The corresponding TIMER light goes on.
To deactivate the timer function, press the
TIMER button repeatedly until the TIMER light
(1H, 4H or 8H) is off.
Set the humidity level
Note
Make sure that the water tank is lled with water
before the humidier can function (see the chapter 'Get started', section 'Prepare for humidication').
Press the HUMI button once or more times to set the desired air humidity to 40,
50, 60 percent or no preset level.
» The humidity light (40, 50 or 60) of the
set humidity level turns on.
» For HU4802, The humidity indicator
light is in red if the desired humidity
level is not reached. It turns blue when the desired humidity level is reached. For HU4803, the actual humidity level is displayed on the center of the control panel.
Tip
A comfortable humidity level is from 40RH% to 60RH%.
You can choose the preferred humidity level at 40%RH, 50%RH or 60%RH..
Note
If no preset humidity level is selected, the humidier will
stop working when the humidity level reaches 70RH% in non-auto modes and 50RH% in auto mode; for HU4802, the humidity indication light will be off.
12 EN
Water level
MAX
Rell water
When there is not enough water in the water
tank:
the water level drops and the red
indicator light starts blinking.
the humidier continues to work for 30 minutes and then stops working.
You have to rell water into the water tank.
Note
The humidier stops humidifying if you do not rell the
water after 30 minutes. The red blinking and remains on.
If the water tank is empty when the humidier is
plugged in and switched on, the red blinks for 2 minutes and then remains on before the water tank is relled with water.
It is normal to nd some water left in the tank.
indicator light stops
indicator light
Water level can be observed through the transparent water tank window.
1 Switch off the humidier and unplug it.
2 Remove the upper unit by holding it at
both sides.
3 Fill the water tank with cold tap water
until water reaches the maximum water indication level.
English
13EN
Note
When lling water, do not exceed the maximum water
level, or water might leak from the drain hole and air inlets.
Do not shake the water tank when moving it, or water
might leak from the drain hole and air inlets.
Do not ll water through the air outlets on top of the
humidier.
4 Place the upper unit back onto the water
tank.
14 EN
5 Clean your
humidifier
Note
Always unplug the humidier before you clean it.
When pouring water from the water tank, make sure
to pour water from the opposite side of the drain hole
and air inlets.
Never use abrasive, aggressive, or ammable cleaning
agents such as bleach or alcohol to clean any part of the humidier.
Clean the body of the humidier
Regularly clean the inside and outside of the humidier to prevent dust from collecting.
1 Wipe away dust with a soft dry cloth from
the body of the humidier.
2 Clean the air inlet and the air outlet with a
soft dry cloth.
Clean the water tank
English
Clean the water tank every week to keep it hygienic.
1 Take out the humidication lter and the
lter support.
2 Fill the water tank for 1/3 with water.
3 Add some mild washing-up liquid to the
water in the water tank.
4 Clean the inside of the water tank with a
soft clean cloth.
5 Empty the water tank into a sink.
6 Put the humidication lter and the lter
support back into the water tank.
15EN
6 Clean the
humidification filter
Clean the humidication lter every week to keep it hygienic.
1 Switch off the humidier and unplug it.
2 Remove the upper unit by holding it at
both sides.
3 Take out the humidication lter and the
lter support from the water tank.
4 Remove the humidication lter from the
lter support.
5 Soak the humidication lter in tap water
for one hour.
16 EN
Tap Water
1 Hour
6 Rinse the humidication lter under a
slowly running tap. Do not squeeze or wring the lter when cleaning.
10 Put the upper unit back onto the water tank.
English
7 Let excess water drip off the
humidication lter.
8 Assemble the humidication lter round
the lter support.
9 Put the humidication lter and the lter
support back into the water tank.
Note
Do not squeeze or wring the lter. This might damage
the lter and impact humidication performance.
Do not dry the lter under direct sunlight, unless it is
assembled back onto the lter support
17EN
7 Replacing the
filters
Replace the humidication lter
Replace the humidication lter every three months for optimal performance. If the lter is in good condition, you could use it for a longer period of time. Make sure to replace the humidication lter at least once a year.
Note
Use only Philips original humidication lter HU4102.
Tip
Register your product at www.philips.com for further
information on how to replace your lter.
1 Switch off the humidier and unplug it.
2 Remove the upper unit by holding it at
both sides.
3 Take out the humidication lter and the
lter support from the water tank.
4 Remove the humidication lter from the
lter support.
18 EN
5 Remove the packaging material from the
new humidication lter.
8 Put the upper unit back onto the water
tank.
English
6 Assemble the new humidication lter
around the lter support.
7 Put the lter and the lter support back
into the water tank.
Tip
You can easily nd more information about how to
replace the lter in our web page or by calling our Consumer Care Center.
19EN
Replace the anti-bacterial lter
Note
The anti-bacterial lter is only available for HU4803.
Use only Philips original anti-bacterial lter HU4112.
Replace the anti-bacterial lter at least once a year to prevent the bacteria from growing in the water tank.
1 Switch off the humidier and unplug it.
2 Remove the upper unit by holding it at
both sides.
3 Take out the lter support from the water
tank and remove the lter.
4 Pull and remove the old anti-bacterial lter
from the lter support. Then, discard it.
5 Push the new anti-bacterial lter to the
lter support.
20 EN
6 Assemble the lter around the lter
support.
7 Put the lter and the lter support back
into the water tank.
8 Put the upper unit back onto the water
tank.
English
21EN
8 Troubleshooting
This chapter summarizes the most common problems you could encounter with the humidier. If you are unable to solve the problem with the information below, contact the Consumer Care Center in your country.
Problem Possible solution
The humidier does not work. Make sure that there is power supply to the humidier.
Make sure that the water tank is lled with water and the upper unit is placed properly onto the water tank.
There is no air humidication. • Make sure that the water tank is lled with water and the upper
unit is placed properly onto the water tank.
The humidier will stop working if the current humidity level reaches 70%RH. Humidity level above 70%RH does not make users feel comfortable, so the humidier automatically turns off to ensure optimal humidication performance.
The water tank leaks. Make sure that the humidier is not overlled with water.
Make sure that the humidier is well assembled/connected
every time after you clean it or after you remove the upper unit and/or water tank for relling.
Make sure that the water tank is properly placed. If the problem persists, contact the Consumer Care Center in your country.
I do not see the current humidity indication change.
There are some white deposits on the humidication lter.
The lter turns yellowish after some time.
There is unpleasant smell coming out from the humidier.
Make sure that you have assembled the humidication lter round the lter support.
The humidication lter is dirty. Rinse and/or descale the humidication lter (see the chapter ‘Clean the humidication lter’).
Your room might have too much ventilation. Please close doors and windows.
Your room size is too big. The recommended room size is 25m² for both HU4802 and HU4803.
The white deposits are called scale and they consist of minerals from the water. Scale on the humidication lter affects the humidifying performance, however it does not harm your health. Please follow the cleaning instructions in the user manual.
The yellow deposits is a natural effect of the wick material, and it has no impact on humidication performance. Clean the humidication lter frequently to remove the scale, and replace the humidication lter every three month.
Make sure that the water tank is lled with water.
Clean the humidication lter (see the chapter ‘Clean the
humidication lter’).
22 EN
Problem Possible solution
No air comes out of the air outlet.
I do not see visible mist coming out of the humidier. Is it working?
I want to check whether the humidity sensor works or not.
Put the plug of the humidier into the wall socket and switch on the humidier.
When mist is very ne, it is invisible. This humidier has a NanoCloud humidication technology, which produces healthy humid air from the outlet area without formation of water mist. Therefore, you cannot see the mist.
Gently blow moist air into the humidity sensor. After a while, the humidity indication changes. Note that for HU4802, if the initial humidity indication is already 60 percent, the humidity indication light stays blue when you blow moist air towards the sensor; for HU4803, the indication can show the actual humidity level from 20%RH to 95%RH.
English
23EN
Loading...