PRODUCT INFORMATION
HR1821 = juice extractor with detachable pulp container + cup
Power consumption : 220 W Voltage : 110 V, 50 - 60 Hz
120 - 127 V, 50 - 60 Hz 220 - 240 V, 50 - 60 Hz
Volume (of juice cup) : 400 ml Volume (of pulp container) : 500 ml Dimensions of product : 220 x 190 x 278 mm Dimensions of fancy box : 260 x 215 x 360 mm Weight fancy box : 2.9 kg Cord length : 1.1 m
Foam separator is integated with juice cup lid Spout is detachable for easy cleaning
SERVICE INFORMATION
- This appliance is intended for household use only.
- Always check the sieve. If any cracks or damage are detected, replace the sieve.
- Do not let the appliance run for more then two minutes without interruption, allow it to cool down for two minutes before you continue.
- Do not clean any of the parts in a dishwasher.
- Do not use abrasive cleaning agents, scourers, wiretool, acetone, alcohol etc.
- The appliance is provided with a safety system. If all parts are not properly mounted together; the appliance will not work. Check whether the parts have been connected in the right way. But turn off the power fi rst.
This product meets the requirements regard­ing interference suppression on radio and TV.
The intended sequence of putting the appliance together by user is as follows:
1. Snap juice spout onto pulp collector
2. Place pulp collector in position
3. Place sieve
4. Place lid on pulp collector (by aligning the hook on lid and the corresponding rectangluar hole on pulp collector)
5. Engage two locking latches
6. Put pulp container onto main housing
When probably placing lid on pulp collector, there will be a gap of about 9 mm between lid and pulp collector on the switch side. This is normal.
When pressing lid to close, a rib on lid will press onto a linkage pin in pulp collector, which in turn press onto another linkage pin (integrated with cover plate) on main housing. This then moves down the cover plate and exposes the safety micro­switch. Upon engaging locking latch, the safety micro-switch is activated by a pin on the locking latch and the appliance can be switched on. If pulp collector and lid are not probably assembled, the cover plate will prevent the activation of safety micro-switch.
Test the safety micro-switch by engaging and disengaging the locking latch on switch side.
The drive coupling is screwed onto the motor shaft by means of a right-handed thread.
The drive coupling can be disconnected from the motor shaft by blocking a slot in motor shaft, which is accessible through a slot on bottom cover.
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
4322 277 01073 02/10
PARTS LIST
HR1821/A / HR1821/B
Pos Service code Description
9965 000 11070
1
9965 000 11770
2
9965 000 15545 4822 480 10235
3
9965 000 11771
4
9965 000 15546 9965 000 11772
5
9965 000 15547
4822 528 11285
6
9965 000 11773
7
9965 000 15548 9965 000 11774
8
9965 000 11775
9
9965 000 11776
10
9965 000 11777
11
9965 000 11778
12
9965 000 11779
13
9965 000 11780
14
9965 000 11781
15
Pusher Lid (incl. insert) /A Lid (incl. insert) /B Sieve Pulp collector complete /A Pulp collector complete /B Juice spout /A Juice spout /B
Coupling Main housing /A Main housing /B Locking latch on switch side Hinge Locking latch on back side
Bottom cover complete Switch bracket Micro switch Cover plate Switch
Pos Service code Description
16
9965 000 11782 9965 000 15549 9965 000 15537
17
9965 000 15538 9965 000 11783 9965 000 15539
18
9965 000 15550
9965 000 15540
19
9965 000 15541 9965 000 15542 9965 000 11785 9965 000 15543 9965 000 11787
20
9965 000 15551
9965 000 11786
21
9965 000 15544
22
9965 000 01057
23
Switch cap /A Switch cap /B Motor 110 V (with RFI) Motor 120-127 V (without RFI) Motor 220-240 V (with RFI) Pulp container detachable /A (also suitable for older versions) Pulp container detachable /B
Power cord - Mexico Power cord - Argentina Power cord - Hong Kong Power cord - PRC Power cord - General Juice cup incl. lid /A Juice cup incl. lid /B
Vibration rubber Capacitor 0,22 µF Capacitor 0,10 µF
AC
110V
R.H.
Chock
8.5µH
NC
C
Main
switch
110 V with RFI Circuit diagram 120-127 V without RFI Circuit diagram
NO
C22
0.22µF
R.H.
Chock
Motor
Main
switch
35µH
35µH
Main
switch
A
C
AC
120-127 V
NC
Motor
NO
15µH
NC
C
NO
Motor
A
AC
220V
8.5µH C23
0.1µF
220 V with RFI Circuit diagram
A
15µH
2-3