Shaver
HQ 5426
Micro Action Plus
Philips Domestic Appliances and Personal Care
Service Manual
|
|
|
SAP coding HQ 5426 |
HINTS FOR REPAIRS |
TECHNICAL DATA |
|
|
- Remove shaving unit, to prevent damages during repairs. |
Voltage |
: |
100-240 V 50/60 Hz |
- Remove the screws A1 (2x). |
Power consumption |
: |
Motor depending |
- Remove cover. |
Motor voltage |
: |
54 V |
|
Power system |
: |
Mains |
|
Shaving heads |
: |
HQ5+ - 4222 036 05451 |
-To remove the trimmer, first disassemble the trimmer slide by pushing down the locking pegs (2 x “X” in exploded view) and move the slide slightly outwards.
-Make room between trimmer and cover with a small screwdriver (“Y” in exploded view).
-Remove screws B1 (2 x).
-The PC-board with motor and hairchamber can now be removed from the housing.
-Detach the motor clamping springs (item 16) on the bearing block with a small screwdriver.
This product meets the requirements regarding interference suppression on radio and TV.
After the product has been repaired, it should function properly and has to meet the safety requirements as officially laid down at this moment.
Published by Philips Domestic Appliances and Personal Care |
Printed in the Netherlands |
© Copyright reserved |
Subject to modification |
4322 277 00796 02/09