Philips HQ32A Service Manual

Service
Service
Service
Domestic Appliances and Personal Care
Battery Shaver
HQ 32/A
Marco Polo
HINTS FOR REPAIRS
DISASSEMBLY
-
Remove the shaving unit, to prevent damages during repairs.
-
Unlock the snaplocks from the housing/cover (y-y).
-
Lift the motor unit out of the housing.
-
Unlock the peg-clamping ’Z’ (2X) between frame (item 13) and hair chamber (item 5).
ASSEMBLY
-
The assembly must be carried out in the reverse order of what is described under Disassembly.
-
When fitting the shaver it must be checked if wiring is correctly positioned.
SK2
TECHNICAL DATA
Operating voltage Power supply
Shaving heads Comfort control
SAP Coding
SK1
+
A 2X1.5V LR6
:
3V
:
2X AA/LR6 battery
:
external 3V /500mA
:
2X HQ3
:
fixed setting
:
HQ 32
M
Published by Philips Domestic Appliances and Personal Care Printed in The Netherlands Copyright reserved Subject to modification
©
4322 277 00336 00/05
HQ 32/A
1
2
3
10
4
11
Y
5
Z
6
12
7
8
13
14
9
Y
1 4222 036 02830 Protection cap 2 4222 036 01340 Head housing 3 4822 690 30471 HQ3 shaving head 4 4222 036 02780 Head holder 5 4222 036 02840 Hairchamber
6 4222 036 03380 Housing 7 4222 036 02850 Gearwheel 8 4222 036 02860 Interm. gearwheel 9 4222 036 02890 Pinion 10 4222 036 02900 Motor
11 4222 036 03390 Cover 12 4222 036 03400 Battery cover 13 4222 036 02880 Frame 14 4222 036 02770 Cleaning brush
Loading...