Philips HO User Manual

Page 1
Philips T5 VHO Extreme Temperature System
Ideal for high-bay applications without climate control
T5 COLLECTION
Lower the costs of your ceilings
With the Philips T5 VHO Extreme Temperature System, you can useT5 lamps in high-bay applications without sacrificing light output due to hot or cold temperatures.
Provides high light output even in spaces without climate control
• Lumen output is >90% from 65˚F to 170˚F (20˚C to 75˚C) due to amalgam technology
• More light over the life of the lamp than a standard 400W HID system
Operates on existing electrical system
• 277V–480V input voltage range eliminates the need for rewiring your electrical system
*
† This lamp is better for the environment because of
its reduced mercury content.All Philips ALTO lamps give you end-of-life options which can simplify and reduce your lamp disposal costs depending on your state and local regulations.
Reduce total cost of ownership (TCOO) when compared to a standard HID 400W system
• Reduced energy costs—save up to 40 system watts
• Reduced maintenance costs— up to 75% longer lamp life◊which extends the relamping cycle
• Reduced costs since less lamps are needed to meet lumen requirements
(*, ‡, , ** See page 2 for footnotes)
**
Page 2
105
100
95
90
85
80
75
70
65
60
Relative Light Output (%)
Ambient Temperature ˚C
0˚C 10˚C 20˚C 30˚C 40˚C 50˚C 60˚C 70˚C 80˚C
32˚F 50˚F 68˚F 86˚F 104˚F 122˚F 140˚F 158˚F 176˚F
PhilipsT5 VHO Extreme Temperature lamps featuringALTO®Lamp Technology
Rated Average Life in HoursRated Average Life in Hours
BASE D ON 3 HOU RS PER START
2
25,000
BASE D ON 12 HO URS PER S TART
3
35,000
Programmed Start Ballast
0 5,000 10,000 15,000 20,000 25,000 30,000 35,000
0 5,000 10,000 15,000 20,000 25,000 30,000 35,0000 5,000 10,000 15,000 20,000 25,000 30,000 35,000
100%
98%
96%
94%
92%
90%
88%
100%
98%
96%
94%
92%
90%
88%
Lamp Operating HoursLamp Operating Hours
Light Output (%)Light Output (%)
Lamp Ordering, Electrical andTechnical Data
Product Ordering Pack. Temp. Length 3 Hr. 12 Hr. Initial Design Lumen Number Code Watts Qty. (Kelvin) (In.) Start
2
Start
3
Lumens
4
Lumens5CRI Maint.
21771-1 F95T5/835/VHO/A/ALTO 95 40 3500 46 25,000 35,000 7200 6900 85 90% 21772-3 F95T5/841/VHO/A/ALTO 95 40 4100 46 25,000 35,000 7200 6900 85 90%
Color Nom. RatedAvg.Life (Hrs.)1Approx.
1) Rated average life is the length of operation (in hours) at which point an average of 50% of a large sample of lamps will still be operational and 50% will not.
2) Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently.
3) Average life under engineering data with lamps turned off and restarted once every 12 oper ating hours on a programmed star t ballast. Lamp life is appreciably longer if lamps are started less frequently.
4) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hour s of operating life, when the output is measured during operation on a high frequency reference ballast under standard laboratory conditions. For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp. The ballast factor is a multiplier applied to the designated lamp lumen output.
5) Design lumens are the approximate lamp lumen output at 40% of the lamp’s r ated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions.
This lamp is better for the environment because of its reduced mercury content.All Philips ALTO local regulations.
lamps give you end-of-life options which can simplify and reduce your lamp disposal costs depending on your state and
Note:T5 VHO lamps have new miniature flat pin bases which require new GX5 sockets. Above specifications subject to change without notice.
Performance (Relative Light Output vs.Temperature)
PhilipsT5VHO Extreme Temperature Lamps vs. Standard F54T5 Lamps
90% Lumen Maintenance
Philips T5 VHO Extreme Temperature Lamps
Footnotes from front page:
* 90% lumen maintenance at 17,500 hours for theT5 VHO lamp compared to 65% lumen maintenance at 8000 hours for the MH400/U lamp.
‡ 458 system watts (MH400/U) – 418 system watts (T5VHO) = 40 system watts.
35,000 rated average life (T5 VHO at 12 hours per star t) compared to 20,000 rated average life (MH400/U at 13 hours per star t)
** For example, with 7200 initial lumens, you only need (4) 95W T5 VHO lamps instead of (6) T5 54W HO lamps when replacing a standard 400W HID System.** For example,with 7500 initial lumens, you only need (4)
95WT5 VHO lamps instead of (6)T5 54W HO lamps when replacing a standard 400W HID System.
Rated Average Life
1
Philips T5 VHO Extreme Temperature Lamps
Page 3
LAMP
BALLAST
BLUE
YELLOW
BLACK/ORANGE
BLACK/WHIT E
RED
(HOT)
(NEUTRAL )
Yellow leads must be connected for (1) lamp operation
Advance 277V–480V (1) or (2) lamp 95WT5 VHO Ballast
LAMP
BALLAST
BLUE
YELLOW
BLACK/ORANGE
BLACK/WHITE
RED
(HOT)
(NEUTRAL )
LAMP
Ballast Ordering, Electrical andTechnical Data
No.of Input Starting Ballast Catalog Input Power Ballast Line Current Starting Lamps Volts Method Family Number ANSI (Watts) Factor (Amps) Temp (˚F/˚C)
1 277 PS Optanium JOP-2S95-G 116W 1.1 0.42A -19/-28 1 347 PS Optanium JOP-2S95-G 116W 1.1 0.35A -19/-28 1 480 PS Optanium JOP-2S95-G 116W 1.1 0.24A -19/-28 2 277 PS Optanium JOP-2S95-G 206W 1.0 0.74A -19/-28 2 347 PS Optanium JOP-2S95-G 206W 1.0 0.59A -19/-28 2 480 PS Optanium JOP-2S95-G 206W 1.0 0.43A -19/-28
Above specifications subject to change without notice.
Lamp Maximum Min.
Features
• Programmed Start ballast
• Ballast factor of 1.0 for 2-lamp version
• 277V–480V input voltage range, 50/60Hz
• 194˚F/90˚C maximum case temperature
• -19˚F (-28˚C) minimum starting temperature
• <10%Total Harmonic Distortion (THD)
• One or two lamp operation
General Specifications
Section I — Physical Characteristics
1.1 The electronic ballast shall be furnished with integral leads color coded to ANSI standard C82.11.
Section II — Performance Requirements
2.1 The electronic ballast shall be programmed start.
2.2 The electronic ballast shall operate from 250V–528V.
2.3 The electronic ballast shall maintain constant light output, for line voltage variations of 10% of rated supply voltage.
2.4 The electronic ballast input current shall have Total Harmonic Distortion (THD) of less than 10% at maximum light output for primary lamps.
2.5 The electronic ballast shall have a Power Factor greater than 98% at full light output.
2.6 The electronic ballast shall have a minimum ballast factor of 1.0 for primary lamp applications.
2.7 The electronic ballast lamp current crest factor shall be 1.7 or less in accordance with lamp manufacturer recommendation.
2.8 The electronic ballast shall withstand a sustained open circuit and output conditions without damage.
2.9 The electronic ballast shall be Sound Rated A.
2.10 The electronic ballast shall be a high frequency electronic type and operate above 40 kHz to avoid interference with infrared control systems, and eliminate visible flicker.
2.11 The electronic ballast shall comply with ANSI C82.11,where applicable.
2.12 The electronic ballast shall provide transient immunity as specified in ANSI C62.41.
2.13 The electronic ballast shall provide end of life protection circuitry.
2.14 The electronic ballast shall have a minimum starting temperature of -19°F (-28°C) forT5VHO lamps.
Section III — Regulatory Requirements
3.1 The electronic ballast shall not contain any Polycholorinated
Biphenyl (PCB’s).
3.2 The electronic ballast shall be Underwriters Laboratories (UL 935)
listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified, where applicable.
Section IV — Other
4.1 The manufacturer shall have a fifteen-year history of producing
electronic ballasts for the North American market.
4.2 The electronic ballast shall be produced in a factory certified
to ISO 9001 Quality System Standards.
Wiring Diagram–Lamp Operation
Advance JOP-2S95-G T5 VHO for 2-lamp version ballast
Enclosure Dimensions
Advance JOP-2S95-G T5 VHO Ballast
A . . . . . . . 1.18"
B . . . . . . . 1.70"
C . . . . . . 16.34"
D . . . . . . 16.70"
Page 4
Philips Lighting Company 200 Franklin Square Drive P.O. Box 6800 Somerset, NJ 08875-6800 1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050
A Division of Philips Electronics Ltd.
www.philips.com
10275 West Higgins Road Rosemont, IL 60018-5603 1-800-322-2086
A Division of Philips Electronics North America Corporation
www.advancetransformer.com
©2008 Philips Lighting Company, A Division of Philips Electronics North America Corporation
All rights reserved. Reproduction in whole or part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent or other industrial or intellectual property rights.Data subject to change without notice.
09/08 P-5904-A
Loading...