Philips HI559 Service Manual

Steam Iron
HI559
Philips Domestic Appliances and Personal Care
Service Manual
PRODUCT INFORMATION
Features
- Integrated cord winder
- Spray feature
- Variable steam (Max 30 g/min)
- Shot Of Steam, SOS (60 g/min)
- Vertical steam (60 g/min)
- Self-clean function
- Anti-drip function
- Cord length 2.4 m
- Anodilium soleplate
- Tank capacity 250 ml
Safety Information
- This product meets the requirements regarding interference suppression on radio and TV.
- After the product has been repaired, it should function properly and has to meet the safety requirements and legal regulations as officially laid down at this moment.
TECHNICAL INFORMATION
Voltage : 220 - 240 V
Frequency : 50 - 60 Hz
Power consumption : 1650 - 1960 W
Dimension (F-box) : 333 mm x 273 mm x 149 mm
Weight (Iron) : 1990 g
Vertical steam
When the iron is kept in a vertical position, the S.O.S. button can be used to iron hanging fabrics as curtains.
Self-clean function
When the self-clean button is pushed down, a sudden fl ow of water is released from the tank into the heated soleplate.
This thermal shock will cause scale particles come loose from the steam chamber. These particles are then fl ushed out through the steam vents by the water.
Anti-drip
Water is only released through the tank valve into the steam chamber if the soleplate temperature is high enough to evaporate all water. If the temperature is not hot enough, the tank valve is closed by means of the bi-metal disc.
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
04/01
DISASSEMBLY ADVICE IRON
HI559
DIAL 1, 2, 3
RATTLE SPRING 5
BACK PLATE 4
remove SCREW C 1x remove BACK PLATE 4
INLAY 6
OPERATION KNOBS 7
DOOR 8
DOOR HOLDER/
DEAIR. BUSH 9
SPRAY UNIT 10
PILOT LIGHT 11
remove SCREW C 1x remove BACK PLATE 4 remove INLAY 6
HANDLE 15
SPRAY PUMP 16
S.O.S.PUMP 17
TANK 18
SELF CLEAN BUTTONS 19
SEALINGS 22
remove SCREW C 1x remove BACK PLATE 4 remove INLAY 6 remove SCREW A 2x remove DIAL 1, 2, 3 remove SCREWS cord clamping remove SCREW B 3x remove SCREW A1 2x remove HANDLE 15
THERMOSTAT 20
THERMOSTAT PIN 21
SLIDE UNIT 12, 13
NEEDLE 14
remove SCREW C 1x remove BACK PLATE 4 remove INLAY 6 remove SCREW A 2x
SEALINGS 22
COVER 25
TYPE PLATE 26
SOLEPLATE 23
ANTI-DRIP VALVE 24
remove SCREW C 1x remove BACK PLATE 4 remove INLAY 6 remove SCREW A 2x remove DIAL 1, 2, 3 remove SCREWS cord clamping
cord set pilot light
remove SCREW B 3x remove SCREW A1 2x remove HANDLE 15 remove SCREW F 3x
2-7
REPAIR INSTRUCTIONS IRON
IMPORTANT
Due to the high wattage of the iron, only the specifi ed cordsets must be used.
NOTES :
1) For standardisation reasons :
Rattle spring : 5 pieces will be supplied when ordered. Type plate : No info about the type number and voltage have been stamped onto the typeplate. When replacing the type plate, engrave at least type number and voltage onto the typeplate with a sharp object.
2) Parts, with numbers from 100 and higher, cannot be ordered separately.
3) After the product has been repaired, it should function properly and has to meet the safety requirements and legal regulations as laid down and officially established at this moment.
ADJUSTMENT AND CONTROL
Thermostat :
Thermostat 20, fi tted to the soleplate 23 has already been adjusted by the supplier and secured by glue. To avoid mal-function of the iron, NEVER re-adjust the thermostat.
Adjustment thermostat 20, supplied as a spare part.
N.B. Before starting to adjust the thermostat, make sure that a gap exists between the lower tip of the ceramic insulating pin
and the real-off bracket. See fi g. 1.
HI559
Connect the connecting strips to an Ohm-meter. Set the thermostat stopper to the position as indicated in fi g. 2. Turn the adjusting screw R clockwise or anti-clockwise until the Ohm-meter indicates “0“. (The contacts closed) Then turn the adjusting screw clockwise until the Ohm-meter indicatesand the contacts have only just been opened. You hear a “click”. While loosely turning the thermostat stopper, check if the thermostat switches in the position as indicated in fi g. 2.
After the thermostat has been adjusted, adjust the real-off bracket. Set the thermostat stopper in the position shown in fi g. 3. The thermostat contacts are closed. (Ohm-meter indicates “0”) Turn the set-screw S clockwise until the contacts have only just been opened. The Ohm-meter indicates. Secure the adjusting screws with a glue.
After adjusting the thermostat, always check the temperature of the soleplate, with the dial set to MAX. position ( 215 ± 25 °C )
For location of testing point, see fi g. 4. The temperature must be measured, after the iron has been connected to the mains for at least 15 min. The max. temperature shall not be higher than 240 °C.
123
45˚-50
˚
RS
2
85˚-90
˚
4
==
Test­point
3-7