Philips HD7132A Service Manual

Combi coffeemaker and kettle

HD7132/A

Domestic Appliances and Personal Care

PRODUCT INFORMATION

Voltage

: 100, 120, 220-240 V

Frequency

: 50-60 Hz

Power consumption

:

1000

W (kettle)

 

:

650

W (coffeemaker)

Contents kettle

: 1000 cc

Contents jug

:

650 cc

Coloursetting

:

white

 

SERVICE INFORMATION

Thermostat switch-off temp. : 140 °C (item 13) Thermal fuse cut-off temp. : 216 °C (item 12)

REPAIR INSTRUCTIONS (coffeemaker)

1.Electrical circuit

When the appliance does not work, check the electrical circuit. If the thermal fuse or thermostat prove defective, the complete pump unit has to be replaced.

2.De-scaling

If the water system is nearly or less clogged by scale then operate the coffeemaker a few times with vinegar or with a 10-15% solution of either vinegar-acid, citric-acid or tartar-acid, into cold tap water.

Do not use other de-scaling agents as these may harm the appliance.

MSH-coding 8827 132 00000

 

 

SWITCH

 

 

FUSE

SWITCH

R

 

CONTROL

E

E

 

 

Th

KETTLE COFFEEMAKER

If this procedure does not restore the function, then switch off the coffeemaker when the acid has passed through during appr. 3 min. Keep the appliance in this condition overnight and continue/repeat the cleaning operation. After the de-scaling procedure, operate the coffeemaker twice with tap water in order to rinse away any residual substances.

Published by Philips Domestic Appliances and Personal Care

Printed in the Netherlands

© Copyright reserved

Subject to modification

4822 729 21799 97/05

PCS 88 421

Philips HD7132A Service Manual