PRODUCT INFORMATION
Voltage : 220-240V
Frequency : 50-60 Hz
Power consumption : 950 W at Boiling mode
100 W at keep warm mode
Capacity : 3.0 Liters
Keep warm :
The unit will switch to keep warm mode after boiling.
Keep warm temperaturecan be selected to 60°C, 85°C and
98°C by mean of a tack switch. The default keep warm
temperature is set to 85°C.
Reboil :
When activate the REBOIL switch, water will be heated up
from the preset keep warm temperature (60°, 85°C or 98°C)
to boiling temperature 100°C in maximum three minutes.
Deodorize:
Can be used under boiling or reboil mode, this will give an
additional 90 sec. boiling time to get rid of the smell of
chlorine in tap water.
Auto power off:
If any of the switches is not activated for a consecutive 72
hours, the power will be cut off automatically together with
error signal.
HOT POT
HD4774
Published by Philips Domestic Appliances and Personal Care Printed in Hong Kong©Copyright reserved Subject to modification
Empty boil protection :
Continuous alternate blinking of ‘Reboil’ & ‘Deodorize’
LEDs and 30 sec. beeping if :
- The unit is plugged in dry, or with less than 0.3 liter of
water.
- Reboil with less than 0.3 liter of water.
Timer:
When timer is set to 8 or 12-hour minutes, all the power
to the heaters will be cut off. At about 18 minutes before
the preset hours, it will switch to boiling mode
automatically.
Detachable lid :
To detach the lid by pressing down the mechanical lock
at the hinge and pull out the lid in the range of 25° to 45°.
4822 729 22001
06/99
Ver.1
Service Manual
Philips Domestic Appliances and Personal Care
SERVICE INFORMATION
Terminal
A
Terminal
B
Terminal
C
THERMAL FUSE
A.C. INPUT
MAIN
HEATER
KEEP WARM
HEATER
AC2
FUSE
U5
U3
AC1
PUMP
OUT
TRANSFORMER
Inner tank :
In case the inner tank is damaged, the
appliance has to be replaced.
item description consist Service code
Heater :
When the appliance does not work,
check the electrical circuit and the
heater resistance.
To measure the heater resistance :
Disconnect all the wires to the heater
terminals A, B and C.
Use a ohm meter to measure theMain
Heater terminal AB, the resistance
should be 56 ohm ± %5.
Use a ohm meter to measure thekeep
warm heater terminal AC, the
resistance should be
529 ohm ± %5.
In case the resistance of any of the
heater out of the resistance ranges,
the appliance has to be replaced.
1 Lid assembly 2 996500000382
2 Sealing ring 996500000375
3 Outlet pipe stand 482225610559
4 Handle 482249810727
5 Socket set 101, 102 482226511575
6 Base 482246410513
7 Rotating ring 482253213131
8 Base plate 482244200689
9 Pipe connector set 104,105,106,107 996500000376
10 Glass pipe 996500000717
11 Water chamber 996500000377
12 Motor 996500000378
13 Thermal fuse 996500000379
14 Thermostat 996500000383
15 Pcb set 108,109,110 996500000380
16 Power cord HK/Singapore 482232111486
17 Filter 996500000381
Handle :
To replace the handle (item 4), the
inner tank has to be taken out. Put the
handle in horizontal position and pull
out on both sides.
Note: Parts of number 100 onwards cannot be ordered separately.