Philips GreenPower LED Series, GreenPower LED production module 120, GreenPower LED production module 150 Application Manual

Horticulture LED Solutions
GreenPower LED production module
Application Guide
The efficient way to improve climate and crop control
September 2018
Contents
Introduction 3
Product information 4
Dimensions 4 Technical specifications 4
Installation of the system 6
Mounting options 6 Positioning of the modules 7 Use of the connector 8 Connecting the system 9 Cable tree design guidelines 10
Ordering data (except NA and Japan) 11
Modules 11 Accessories 11
Ordering data North America (NA) 12
Modules 12 Accessories 12
Accessory information 13
Accessories for module 13 Accessories for cable tree 13
Crop protection and cleaning products 14
Use of cleaning agents, crop protection products and other chemicals 14 Cleaning GreenPower LED products 14 Using pesticides, fungicides and insecticides 14
Compliance with international standards 15
Introduction
Especially designed for your vertical growth system, the GreenPower LED production module is the best solution for new or existing installations. Due to its high energy efficiency and long lifetime, the GreenPower LED production module is the cost-effective way to improve climate and crop control for indoor cultivation environments.
The GreenPower LED production module is available in several spectral versions and in two lengths; 120 cm and 150 cm.
The GreenPower LED production module is available for two regions:
• North America (NA)
• Rest of world: global, except North America and Japan (ROW) For each region dedicated accessories (such as cabling, connectors) are available for an easy and quick installation.
This application guide describes all important technical and safety information of the GreenPower LED production module.
3September 2018 Application Guide - Philips GreenPower LED production module
H1
Product information
Dimensions
W1
W1
H1
L1
Product name Product dimensions (mm/inch)
L1 L2 L3 D1 Ø D2 Ø D2 Ø W1 H1
D2 (Ø)
L2
4.5 / 0.18
D1 (Ø)
L3
10 / 0.39
32 / 1.26
40 / 1.57
Product
EU NAM
weight (kg/lbs)
GP LED production module 120 1213 / 47.76 700 / 27.5 64 / 2.52 19 / 0.75 8.7 / 0.34 7.6 / 0.3 40.5 / 1.59 40.2 / 1.58 1.4 / 3.1
GP LED production module 150 1513 / 59.57 700 / 27.5 64 / 2.52 19 / 0.75 8.7 / 0.34 7.6 / 0.3 40.5 / 1.59 40.2 / 1.58 1.7 / 3.7
Technical specifications
Type Photobiological hazard2
Photon flux Efficacy typical1Power
consumption
Radiation hazard
Minimum viewing distance
(μmol/s) (μmol/J) (W) Retinal Blue (m) (inch)
PM 120
DR/B 120 LB HO 66 3.0 22 Risk Group 2 0.35 14 Exempt group
DR/B/FR 120 LB HO 66 3.0 22 Risk Group 2 0.35 14 Exempt group
DR/B/FR_2 120 MB HO 64 2.7 24 Risk Group 2 0.8 32 Exempt group
DR/W 120 LB HO 66 2.6 25 Risk Group 2 0.5 20 Exempt group
DR/W/FR 120 LB HO 66 2.6 25 Risk Group 2 0.5 20 Exempt group
DR/W 120 LB LO 25 2.5 10 Exempt group N/A N/A Exempt group
PM 150
DR/B 150 LB HO 83 3.0 28 Risk Group 2 0.35 14 Exempt group
DR/B/FR 150 LB HO 83 3.0 28 Risk Group 2 0.35 14 Exempt group
DR/W 150 LB HO 83 2.6 32 Risk Group 2 0.5 20 Exempt group
DR/W/FR 150 LB HO 83 2.6 32 Risk Group 2 0.5 20 Exempt group
DR/W 150 LB LO 31.5 2.5 12.5 Exempt group N /A N/A Exempt group
DR/W 150 LB 62.5 2.6 24 Risk Group 2 0.3 12 Exempt group
FR 150 62.5 2.1 30 Exempt group N/A N/A Exempt group
3
All other radiation hazards
Specifications Details
Optical
Rated average lifetime
1,4
35.000 hrs, L90B50 (90% flux maintenance)
Electrical
Input voltage 120 - 277 V AC, 50-60 Hz
Power factor > 0,9 (> 0,8 for LO versions @ 277 V)
Inrush current 3.0 A - 0.8 ms 120 V
5.5 A - 0.8 ms 230V
7.0 A - 0.8 ms 277V
Environment
Ambient storage temperature -20 to 85 °C / -4 to 185 °F (T
Ambient operating temperature 0 to 40 °C / 40 to 104 °F (T
Max. case temperature
1
40 °C / 104 °F (T
case
)
storage
operating
Cooling Passively air-cooled
Relative humidity 5-95% RH, no condensation allowed during storage,
operation and application
Ingress protection rating IP66
UL/CSA rating Dry, damp and wet locations
Legend:
GP = GreenPower PM = Production Module DR = Deep Red B = Blue W = White FR = Far Red
)
)
LB = Low Blue HO = High Output LO = Low Output
1
Efficacy typical / Rated average lifetime / Max. case temperature
@ T
= 25 °C / 77 °F
ambient
2
For more information about photobiological hazard see page 5
3
The luminaire should be positioned at minimum viewing distance,
so that prolonged staring into the light source is not expected.
4
All measured lifetimes are industry standard measurements
indicating average length of operation and not a performance claim specific to any individual product.
4September 2018 Application Guide - Philips GreenPower LED production module
Important
Influencing factors of light output
As ambient temperature increases, both the photon flux and the photon flux maintenance will decrease. Pollution or damage of optics will also impact the light output.
Thermal protection
The GreenPower LED production module has a built-in thermal protection device. If the temperature of the module exceeds 50 °C / 122 °F the module will blink a few times and then shut off. After cooling down the module will switch on again automatically.
Photobiological hazard
Photobiological safety of lamps and lamp systems (EN 62471). This International Standard describes the photobiological safety of lamps and lamp systems including luminaires. The rating of the GreenPower LED production module according to this standard can be found in the technical specifications.
Risk Group 2: Do not stare at the operating light source. The philosophical basis for this classification is that the lamp does not pose a hazard due to the aversion response to very bright light sources or due to the thermal discomfort.
Caution: Possibly hazardous optical radiation emitted from this product. Do not stare at operating lamp. May be harmful to the eye.
Light source not replaceable
The light source of this fixture is not replaceable. When the light source reaches its end-of-life, the whole fixture needs to be replaced.
Cable not replaceable
The external flexible cable or cord of this luminaire cannot be replaced. If the cord is damaged, the luminaire shall be destroyed.
Not for outdoor use
Modules are not suited to outdoor use (UV effects on material, discoloring).
5September 2018 Application Guide - Philips GreenPower LED production module
Loading...
+ 11 hidden pages