![](/html/e0/e0ae/e0ae7810edd22b3fbba6910a5455b9dc1b48520a2bde875c13a9c3aa31ae3327/bg1.png)
July 2015
Quick installation guide UL/CSA
Product Dimensions in mm (inches)
Length (A) Width (B) Height 1 (C1) Height 2 (C2) Weight
GreenPower LED interlighting module DR/B (deep red/blue) 2491 (98.07) 48 (1.89) 76 (2.99) 33.8 (1.33) 3.57 kg
GreenPower LED interlighting module mounting bracket 89 (3.50) 50 (1.97) 140 (5.51)
Horticulture
LED Solutions
GreenPower LED
interlighting
UP
UP
For double line installation
Optimal area
to apply the
GreenPower LED
interlighting
> 65 cm (25,6")
from top crop leaf
> 40 cm (15,7")
from lowest crop leaf
> 30 cm (11,8")
< 50 cm (19,7")
between modules
UP
Optimal area
to apply the
GreenPower LED
interlighting
> 65 cm (25,6")
from top crop leaf
> 40 cm (15,7")
from lowest crop leaf
For single line installation
UP
UP
C1
B
B
C2
A
C1
C2
Installation
Dimensions
Side Front Back
Warning
Turn power off before installation. All work should
be done according to appropriate electrical codes.
![](/html/e0/e0ae/e0ae7810edd22b3fbba6910a5455b9dc1b48520a2bde875c13a9c3aa31ae3327/bg2.png)
Lamp type Photon flux
[µmol/s]
Useful life time
hours
Photon flux maintenance
ambient 25 °C
Energy consumption
W
GreenPower LED interlighting module DR/B (deep red/blue) 220 25,000 90% 117
Product Order code Order code
12NC 6NC
GreenPower LED interlighting module DR/B (deep red/blue) 9290 009 10406 260992
GreenPower LED interlighting module mounting bracket 9290 008 80406 262220
* The values for service life and photon flux maintenance are valid for an ambient temperature of 25 °C.
For more information about
Philips horticulture LED Solutions visit:
www.philips.com/horti
Write us an e-mail:
horti.info@philips.com
Or tweet us:
@PhilipsHorti
© 2015 Koninklijke Philips N.V. All rights reserved. Philips reserves the right to make changes in
specifications and/or to discontinue any product at any time without notice or obligation and
will not be liable for any consequences resulting from the use of this publication.
Document order number: 3222 635 67104 - UL/CSA
07/2015
Data subject to change.
208-400 V
~ AC ~ AC
Non water
tight area
Ordering data and specifications Philips GreenPower LED interlighting
GreenPower LED
interlighting module
For protection against electrical shock in case of a fault connect green/yellow wire to an external protective
conductor. Be sure the driver is after installation on top of the module. For more detailed information about the
electrical connection please check the Application Guide.
Max inputvoltage: 208-400 V.
GreenPower LED interlighting
module mounting bracket
The “non water tight area” must be built into a water tight area. E.g. into a water tight junction box or water tight
connectors.
Non water
tight area
Water tight area of the product
208-400 V
~ AC ~ AC
Installation of a fixed system