Steam Iron (LESI)
GC1121
Philips Domestic Appliances and Personal Care
Service Manual
PRODUCT INFORMATION
Features
- Color White/Purple
- Dynaglide soleplate (Non stick)
- Tank capacity (150 ml)
- Integrated Calc Clean
- Steam rate 15 grams/min
- Extra steam 25 grams/min
- Spray Feature
Safety Information
- This product meets the requirements regarding
interference suppression on radio and TV.
- After the product has been repaired, it should function
properly and has to meet the safety requirements and
legal regulations set by the related countries.
TECHNICAL INFORMATION
Voltage : 220 ~ 240 V
Frequency : 50 ~ 60 Hz
Power consumption : 1200 ~ 1440 W
Dimension (F-box) : 272 x 107 x 140 mm
Weight (Product) : 870 grams
Water advice
Suitable for tap water use. However if the tap water in your
area is very hard, we advise you to mix it with a equal portion
of distilled water or to use distilled water only.
Dynaglide Soleplate
This is a non-stick coating that has property of smooth
gliding, high scratch resistant, very easy to clean and durable.
Calc clean
The integrated Calc clean function ensure a longer lifetime
using normal tap water by removing the scale out of the steam
chamber.
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
03/07
DISASSEMBLY ADVICE
PARTS LIST
GC1121
BACKPLATE 3
LAMP ASSY 8
SWIVEL 9
CORDSET 10
INLAY 5
Remove screw A (1x)
Remove BACKPLATE 3
Remove LAMP ASSY 8
Remove SWIVEL 9
Remove CORD SET 10
Remove DOSING ASSY 1
Remove SPRAY KNOB 4
Remove screw B (1x)
Remove INLAY 5
Remove PUMP ASSY 7
DIAL 2
TANK SET 6
Pos Service code Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
4239 021 21250
4239 021 19740
4239 026 14900
4239 026 14030
4239 026 12110
4239 022 54190
4239 020 90560
4239 021 14520
4239 025 96960
4239 000 06720
4239 000 07320
4239 026 12830
4239 026 12070
4239 015 70150
4239 015 52140
4239 015 54210
4239 022 53650
Dosing assy (with extra steam)
Dial printed
Backplate
Spray knob (purple)
Inlay (with spray feature)
Tank set (purple)
Pump assembly
Lamp assembly
Swivel
Cordset EU
Cordset UK
Thermostat bush
Cover
Isolation stud
Cover seal
Tank seal
Soleplate assembly (230 V)
THERMOSTAT BUSH 11
COVER 12
ISOLATION STUD 13
COVER SEAL 14
SOLEPLATE ASSY 16
Remove DIAL 2
Remove DOSING ASSY 1
Remove SPRAY KNOB 4
Remove screw B (1x)
Remove INLAY 5
Remove PUMP ASSY 7
Remove screw C (3x)
Remove TANK SET 6
Remove
THERMOSTAT BUSH 11
Remove screw D (3x)
Remove COVER 12
Remove ISOLATION STUD 13
Remove COVER SEAL 14
Remove SOLEPLATE ASSY 16
REPAIR INSTRUCTIONS
- In case of any defect in thermostat, the complete soleplate has to be resplaced.
- No information about the type number has been stamped into the type plate.
When replacing the type plate, engrave at least type number and voltage onto the
type plate with a tool.
- After the product had been repaired, it should function properly and has to meet
the safety requirement and legal regulations set by the related country.
N
220-240 V
THERMOSTAT
L
E
RESISTOR
LAMP
THERMAL
FUSE
HEATING
UNIT
2-3