Steam Iron (LESI)
GC1015
Philips Domestic Appliances and Personal Care
Service Manual
PRODUCT INFORMATION
Features
- Colour white/green
- Aluminium soleplate
- Tank capacity (150 ml)
- Integrated calc clean
- Steam rate (15 g/min)
- Spray feature
Safety Information
- This product meets the requirements regarding
interference suppression on radio and TV.
- After the product has been repaired, it should function
properly and has to meet the safety requirements and
legal regulations set by the related countries.
TECHNICAL INFORMATION
- Voltage : 220 ~ 240 V
- Frequency : 50 ~ 60 Hz
- Power consumption : 1200 ~ 1450 W
- Dimension (F-box) : 272 mm x 107 mm x 140 mm
- Weight (Product) : 870 grams
- Water advice : Suitable for tap water use.
However if the tap water in your
area is very hard, we advise you to
mix it with a equal portion of
distilled water or to use distilled
water only.
Soleplate
The Aluminium soleplate used is smooth and corrosion free
which treats fabrics gently.
Calc clean
The integrated Calc clean function ensure a longer lifetime
using normal tap water by removing the scale out of the steam
chamber.
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
03/04
DISASSEMBLY ADVICE
GC1015
BACKPLATE 3
LAMP ASSY 8
SWIVEL 9
CORDSET 10
INLAY 5
Remove Screw A 1x
Remove BACKPLATE 3
Remove LAMP ASSY 8
Remove SWIVEL 9
Remove CORD SET 10
Remove DOSING ASSY 1
Remove Screw B 1x
Remove INLAY 5
Remove PUMP ASSY 7
DIAL 2
TANK SET 6
THERMOSTAT BUSH 11
COVER 12
ISOLATION STUD 13
COVER SEAL 14
SOLEPLATE ASSY 16
Remove DIAL 2
Remove DOSING ASSY 1
Remove SPRAY KNOB 4
Remove Screw B 1x
Remove INLAY 5
Remove PUMP ASSY 7
Remove Screw C 3x
Remove TANK SET 6
Remove THERMOSTAT BUSH 11
Remove Screw D 3x
Remove COVER 12
Remove ISOLATION STUD 13
Remove COVER SEAL 14
Remove SOLEPLATE ASSY 16
REPAIR INSTRUCTIONS
- In case of any defect in the thermostat, the complete soleplate has to be replaced.
- No information about the type number has been stamped into the type plate.
When replacing the type plate, engrave at least type number and voltage onto the
type plate with a tool.
OPTIONAL (accessories)
- No specific issues
2-4