Philips FWM185 Diagram

Mini System
FWM185/
all versions
TABLE OF CONTENTS
Specifi cations ..............................................................1-2
Measurement Setup ....................................................1-3
Block Diagram ................................................................2
Wiring Diagram ...............................................................3
Cassette Board...............................................................4
MCU & USB Board.........................................................5
CD Board ........................................................................6
AMP Board .....................................................................7
Mechanical Exploded View & Parts List .........................8
Revision List ...................................................................9
©
Copyright 2008 Philips Consumer Electronics B.V. Eindhoven, The Netherlands
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwise without the prior permission of Philips.
Published by SL0823 Service Audio Printed in The Netherlands Subject to modifi cati
Page
CLASS 1
LASER PRODUCT
3141 785 31684
Version 1.4
SPECIFICATION
1-2
AMPLIFIER
1 KHz (Low channel - both channels driven)
................................................... 30 W per channel (8 :)
10 KHz (High channel - both channels driven)
................................................... 30 W per channel (8 :)
Total output power ............................................... 120 W
Signal-to-noise ratio .......................... t 62 dBA (IEC)
Frequency response ......... 63 – 16000 Hz, ± 3 dB
CD PLAYER
Frequency range .................................. 63 – 16000 Hz
Signal-to-noise ratio ............................................ 65 dBA
TUNER
FM wave range ................................... 87.5 – 108 MHz
MW wave range ................................ 531 – 1602 kHz
TAPE DECK
Frequency response
Normal tape (type I) ...... 125 – 8000 Hz (8 dB)
Signal-to-noise ratio
Normal tape (type I) .................................... 35 dBA
Wow and flutter ......................................... d 0.4% DIN
USB PLAYER
USB ................................................................... 12Mb/s, V1.1
......................................... support MP3 and WMA files
Number of albums/folders ................. maximum 99
Number of tracks/titles ...................... maximum 400
SPEAKERS
2-way Bass Reflex System
Impedance ........................................................................ 8 :
Woofer ................................................................... 1x10 cm
Tweeter ...................................................................... 1x5 cm
Dimensions (w x h x d)..........21.5x34.9x16.2 (cm)
GENERAL
AC Power ..................................... 220 – 230 V / 50 Hz
Dimensions (w x h x d) ........... 22x29.2x27.2 (cm)
Weight (with/without speakers) ..................................
............................................................... approx. 4.9 / 2.3 kg
Specifications and external appearance are subject to change without notice.
e
MEASUREMENT SETUP
Tuner FM
1-3
Bandpass
LF Voltmeter
e.g. PM2534
RF Generator
e.g. PM5326
DUT
250Hz-15kHz
e.g. 7122 707 48001
Ri=50
S/N and distortion meter
e.g. Sound Technology ST1700B
Use a bandpass filter to eliminate hum (50Hz, 100Hz) and disturbance from the pilottone (19kHz, 38kHz).
Tuner AM (MW,LW)
RF Generator
e.g. PM5326
Ri=50
DUT
Frame aerial
e.g. 7122 707 89001
Bandpass
250Hz-15kHz
e.g. 7122 707 48001
LF Voltmeter
e.g. PM2534
S/N and distortion meter
e.g. Sound Technology ST1700B
To avoid atmospheric interference all AM-measurements have to be carried out in a Faraday´s cage. Use a bandpass filter (or at least a high pass filter with 250Hz) to eliminate hum (50Hz, 100Hz).
CD
Use Audio Signal Disc (replaces test disc 3)
DUT
L
R
SBC429 4822 397 30184
S/N and distortion meter
e.g. Sound Technology ST1700B
LEVEL METER
e.g. Sennheiser UPM550
-
Recorder
Use Universal Test Cassette CrO2 SBC419 4822 397 30069
or Universal Test Cassette
LF Generator
e.g. PM5110
Fe SBC420 4822 397 30071
DUT
L
R
S/N and distortion met
e.g. Sound Technology ST170
LEVEL METER
e.g. Sennheiser UPM550
with FF-filter
SERVICE AIDS
1-4
Service Tools:
Universal Torx driver holder .................................4822 395 91019
Torx bit T10 150mm ...........................................4822 395 50456
Torx driver set T6-T20 .........................................4822 395 50145
Torx driver T10 extended .....................................4822 395 50423
GB
All ICs and many other semi-conductors are susceptible to electrostatic discharges (ESD). Careless handling during repair can reduce life drastically. When repairing, make sure that you are connected with the same potential as the mass of the set via a wrist wrap with resistance. Keep components and tools also at this potential.
WARNING
GB
Safety regulations require that the set be restored to its original condition and that parts which are identical with those specified, be used
Safety components are marked by the symbol
!
.
Compact Disc:
SBC426/426A Test disc 5 + 5A ...........................4822 397 30096
SBC442 Audio Burn-in test disc 1kHz .................4822 397 30155
SBC429 Audio Signals disc .................................4822 397 30184
Dolby Pro-logic Test Disc ....................................4822 395 10216
ESD
CLASS 1
LASER PRODUCT
Lead free
INSTRUCTIONS ON CD PLAYABILITY
Customer complaint
"CD related problem"
Set remains closed!
check playability
1
1-5
playability
ok ?
Y
Play a CD
for at least 10 minutes
check playability
playability
ok ?
Y
N
"fast" lens cleaning
check playability
playability
ok ?
N
3
For flap loaders (= access to CD drive possible)
cleaning method
4 is recommended
Standard repair procedure
N
Y
clean the lens
check playability
playability
ok ?
check "EYE-Pattern"
4
Y
N
5
return set
add Info for customer
"SET OK"
return set
1 - 7
For description - see following pages
2
replace Signal Processor
return set
EYE-Pattern
ok ?
Y
check Laser current
Laser current
ok ?
Y
check CD Drive offsets
Y
CD Drive offsets
ok ?
N
replace CD Drive
6
return set
N
replace CD Drive
7
return set
N
replace CD Drive
return set
INSTRUCTIONS ON CD PLAYABILITY
1-6
1
PLAYABILITY CHECK
For sets which are compatible with CD-RW discs
use CD-RW Printed Audio Disc....................7104 099 96611
TR 3 (Fingerprint) TR 8 (600µ Black dot) maximum at 01:00
• playback of these two tracks without audible disturbance playing time for: Fingerprint 10seconds
Black dot from 00:50 to 01:10
• jump forward/backward (search) within a reasonable time
For all other sets
use CD-DA SBC 444A..................................4822 397 30245
TR 14 (600µ Black dot) maximum at 01:15 TR 19 (Fingerprint) TR 10 (1000µ wedge)
• playback of all these tracks without audible disturbance playing time for: 1000µ wedge ≥10seconds
Fingerprint 10seconds Black dot from 01:05 to 01:25
• jump forward/backward (search) within a reasonable time
4
LIQUID LENS CLEANING
Before touching the lens it is advised to clean the surface of the lens by blowing clean air over it. This to avoid that little particles make scratches on the lens.
Because the material of the lens is synthetic and coated with a special anti-reflectivity layer, cleaning must be done with a non-aggressive cleaning fluid. It is advised to use “Cleaning Solvent B4-No2”, available with codenumber 4822 389 10026.
The actuator is a very precise mechanical component and may not be damaged in order to guarantee its full function. Clean the lens gently (don’t press too hard) with a soft and clean cotton bud moistened with the special lens cleaner.
The direction of cleaning must be in the way as indicated in the picture below.
2
CUSTOMER INFORMATION
It is proposed to add an addendum sheet to the set which informs the customer that the set has been checked carefully - but no fault was found. The problem was obviously caused by a scratched, dirty or copy-protected CD. In case problems remain, the customer is requested to contact the workshop directly. The lens cleaning (method 3) should be mentioned in the addendum sheet.
The final wording in national language as well as the printing is under responsibility of the Regional Service Organizations.
3
FAST LENS CLEANING (dry brush)
Use lens cleaning CD
SBC AC300...........................................9082 100 00043
Insert the lens cleaning CD, press PLAY and follow the voice guide´s instructions on the CD.
Sanyo DA12T3
CD Drive
A
A
F
C
B
E
C
D
E
VCC
B
VREF
F
D
9
10
11
12
13
14
15
16
1800
+5V_HF
VrefCD10
A
D
E
B C
F
GND
8
E
D
A
B
C
F
Laser power control
100n
2878
470n
2876
3821
1R
1K
3823
2880
33p
+5V
BC807-40
7879
3817
47R
3820
4R7
47R
3819
1n
2879
2877
47u
1
8
4
7811-A
LM358D
3
2
10K
3822
47R
3818
2841
100n
47n
2869
+5V_HF
LASER DIODE
U >250mV
->Laser damaged !
4,6V
3V
3,3V
3,9V
2V
0,17V
0,17V
Sanyo DA12T3
HF-Amplifier
D3
D2
D1
680R
3905
3903 3K3
BC847B
7877
47n
2818
1K5
3902
5
7
4
2
1
6
3
64
8
9
10
11
470R
3893
+3.3V
2K2
3908
10K
3923
BC847B
7878
BC847B
7876
4n7
2813
3896 100R
220u
2885
2881 560p
47n
2887
560R
3901
2883 470n
2817
4u7
3n3
2814
3898 220R
3895
27K
470n
2884
+3.3V
3909
820R
3907
100R
3920
33K
3897
2882
82p
3K3
3904
2K7
3899
3906
470R
+5V_HF
HFIN
VrefCD10
100p
28152816
22n
LDON to 3826,3827
VREF GE
VDDA1
VRIN
VSSA1
ISLICE
LD
ON
D1
D2
D3
D4
HFIN
HFREF
IREF
CD_DA: 0V / CD_RW: 3V
Σ (A-D)
800mVpp
TB = 0.5µs/div
EYE-PATTERN
1,8V
1,2V
2,4V
2,6V
0,65V
INSTRUCTIONS ON CD PLAYABILITY
1-7
5
EYE-PATTERN SIGNAL – JITTER MEASUREMENT
Measure the signal on the input of the Signal processor using an analog oscilloscope. Please find the exact measuring point in your Service Manual.
See below examples of the signal. Amplitude should read at least 700mVpp using SBC444A.
6
CD DRIVE – LASER CURRENT MEASUREMENT
The laser current can be measured as a voltage drop on a resistor. The resistor is marked in every Service Manual. The value depends on the type of CD drive.
typical value most probably defect
VAMxxxx : 150-230mV 350mV MCDxx : 170-230mV 300mV DA1x : 210-250mV 350mV DA2x : 175-200mV 250mV Use SBC444A (CD-DA) for measurement.
If the oscilloscope shows a signal like the ‘bad’ one, and/or the amplitude decreases within 1 minute - the CD drive has to be replaced.
good
bad
7
CD DRIVE – OFFSET MEASUREMENT
The photodiodes of the CD-drive may have an offset. These offsets have to be compensated by the signal processor. High offsets can lead to poor playability of some CDs (skipping tracks).
To measure the offset values, start the Service Test Program - section “Focus Test” without a CD.
The offsets can be measured with a DC Millivoltmeter directly on the connector (see drawing below). Pin numbering varies from drive to drive.
The values from diode A-D should read 0±10mV. Diodes E and F are less critical.
If one of the offsets is higher than ±10mV the CD drive has to be replaced. Otherwise replace the Signal Processor.