Philips EC2-9 User Manual

LIGHTOLIIÉR*
Lighting Systems EC2-9

Page 1 of 3 Energos Control System 2-Light T8 per 4' (121.92cm) (Nominal) Lens

Feature Specifications - Energos Control System (For standard Energos fixtures consult appropriate EG spec sheets)

Feature Specifications Electrical

Dedicated low voltage (24 VDC) circuit controls the Energos Control Systems. The line voltage circuits control all the standard ballast functions including A/B switch ing, Dimming and Emergency Battery Pack operations.
1. End Cap Sensor Mounting 2. Mid-mounted 8' (243.84cm) Sensor Mounting
ECS occupancy sensors are available in two variations:
• Mounted in the end cap.
• The middle of an 8' (243.84cm) module.
The ECS sysfem confrol-cenfer is fhe Power Pack. The Power Pack, confained in each Masfer Module, inferrupfs fhe circuifs when paramefers dicfafe. The Power Pack can confrol up fo 600 waffs 120 VAC, and 1300 waffs 277 VAC. A maximum of 10 sensors can be used on a single Power Pack. There is no limifafion fo the number of Power Packs fhaf can be "daisy-chained" fo a single ECS circuif.
Emergency baffery packs can be used in conjuncfion wifh ECS for emergency
egress lighfing since all lisfed packs operafe for a minimum of 90 minufes.
EM Packs can be used as momenfary lighfing for emergency circuif for power
fransifions, and smaller packs are recommended for fhis purpose.
Dimming ballasfs can be used in conjuncfion wifh ECS. However, fhe confrol sysfem will only perform ON or OFF operafions and will not affect the level of dim ming sef by fhe dimming ballasfs.
Facfory insfalled ballasf disconnecf allows fhe ballasf fo be disconnecfed from and reconnecfed fo incoming power under load wifhouf fuming fhe enfire circuif off.
Serial Row Linking (SRL)
For every run fhaf SRL is required, order fhe appropriafe SRL end sef from page 2 of this Specification Sheet. Consult Energos Application Guide for more derailed definifions and examples.
provides mulfiple confinuous row communicafion.

Mountings

Cable suspension disfances are on 48" (121.92cm) and 96" (243.84cm) cenfers, and consisf of a 4 1/2" (11.43cm) diamefer canopy finished whife enamel. A 1/16" (0.16cm) diamefer sfainless sfeel aircraff cable accomplishes suspension and is adjusfable from 12" (30.48cm) fo 36" (91.44cm). Power feeds are 18 gauge silver braided cord wifh clear jackef.
Occupancy Sensors:
• Time delay is facfory pre-sef fo 30 minufes.
• Time delay can be field adjusfed from 30 minufes fo a minimum of 30 seconds.
• Daylighf hold-off is facfory pre-sef fo 120 ff-candles (1291.67m-candles).
• Daylighf hold-off is field adjusfable from 120 ff-candles (1291.67m-candles) down fo 10 ff-candles (107.64m-candles).
• Sensors are designed for a defecfion area (sensifivify diamefer) of 16' (487.68cm) when suspended 10' (304.80cm) AFF. Lowering fhe sensor produces a smaller area of detection. See chart and diagram for additional information.

Coverage Diameter

Energos Occupancy Sensor
Coverage Zone Chart
Height of Sensor Broadcast Diameter Task Diameter
10' 0" (304.80cm) 16' 0" (487.68cm) 8' 0" (243.84cm)
9' 0" (274.32cm) 14' 5" (427.99cm) 7' 3" (214.12cm) 8' 0" (243.84cm) 12' 10" (391.16cm) 6' 5" (184.15cm) 7' 0" (213.36cm) 11'3" (336.04cm) 5' 7" (154.18cm)
Job Information
Job Name: Cat. No.:
Lamp(s): Notes:
1 Type:
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • C0808
PHILIPS
LIGHTOLIIËR*
Lighting Systems EC2-9

Page 2 of 3 Energos Control System 2-Light T8 per 4' (121.92cm) (Nominal) Lens

Control Ordering Information

Family Series Lamping &
Distribution
Ballast Lamp Shielding Length Voltage Finish Options
(Blank)
T
= Tandem Switch
E
= Emergency
Ordering Instructions
End Cap ECS Systems
1. Order Master 4' (121.92cm) or 8' (243.84cm) ECS Module.
2. Order Power Feed End Set.

ECS Sensor Sample Runs

4' Run:
4' (121.92cm) Master Module with Single Sensor End Set.
8' Run:
8' (243.84cm) Master Module and standard Energos End Set.
8' Run:
8' (243.84cm) Master Module and Dual Sensor End Set.
12' Run:
Sensor End Set, and Intermediate Cable Assembly.
8' (243.84cm) Master Module, 4' (121.92cm) Slave Module, Dual
Continuous Row Mounted ECS Systems:
1. Determine run length
2. Order a minimum of one master per run. Please see Application Guide for master requirements on runs that exceed 16' (487.68cm).
3. Order the required remaining Master and Slave modules to complete the run.
4. Order Power Feed End Set.
5. Order one CABLE ASSEMBLY per MODULE minus one per run.
6. Order additional Single Cable & Cord Sets for every Master Module in run.

ECS End Sets

f/1
Single Sensor End Set EC2SE36W
Single Sensor SRL End Set EC2SR36W
Dual Sensor End Set EC2DE36W
Dual Sensor SRL End Set EC2DR36W
Single Cable & Power Cord EGCC36
16' Run:
8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, standard
Energos End Set, and Intermediate Cable Assembly.
16' Run:
8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, Single
Sensor End Set, and Intermediate Cable Assembly.
16' Run:
Sensor End Set, and Intermediate Cable Assembly.
Notes:
1. See page 1 of Specification Sheet or consult Application Guide for the definition of Serial
2. Consult the matching EG specification sheet for Luminaire related specifications (i.e.
8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, Single
Row Linking (SRL).
Housing materials, shielding, mounting dimensions, and photometry).
Lightolier is a Philips group brand
Standard End Set EG2EC36W
SRL Standard
End Set EC2ER36W
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.llghtoller.com © 2008 Philips Group • 00808