Philips DVP3268X User Manual

Operation manual
English
Contents
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Front panel controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Viewing pictures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Live, playback and search modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Triggers and alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Philips Communication, Security & Imaging 1
English
SAFETY PRECAUTIONS
CAUTION
RISK OF ELECTRIC
SHOCK. DO NOT OPEN!
CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT OPEN COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
This label may appear on the bottom of the unit due to space limitations.
The lightning flash with an arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Reference
Definition of terms
Cameo: Single camera picture in a multiscreen display. Dwell time: The length of time that an alarm indicator continues to operate
after the action causing it has occurred. The length of time that
one image of a sequence is shown. Full-screen: A display that only shows one picture occupying a full screen. Multiscreen: The division of a display screen so that it shows a certain number
of cameras at the same time. Sequence: Camera pictures shown one after the other in time either in full-
screen or quad modes. Quad: Four camera pictures shown on one display screen.
WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
Attention: Installation should be performed by qualified service personnel only in accordance with the National Electrical Code or applicable local codes.
Power Disconnect. Units have power supplied whenever the power cord is inserted into the power source. The power cord is the main power disconnect for all units.
The socket outlet shall be installed near the equipment and shall be easily accessible.
2 Philips Communication, Security & Imaging
Icons shown on the screen
Play forward
Play reverse
Fast forward
Fast reverse
Pause
Freeze
Zoom
Sequence
Alarm
Motion
Network
Error
Introduction
Introduction
English
Digital versatile recorder for security applications
The Divar is a video recording system that can record multiple camera signals while simultaneously providing live multiscreen viewing and playback. It combines the functionality of a digital recorder with a multiplexer and a switcher.
The unit has comprehensive search and playback facilities for viewing stored video. Once set up, all recording takes place in the background without requiring operator intervention. Maximum recording rates of 60 (NTSC) and 50 (PAL) images per second are guaranteed with unsynchronized cameras. The recording rate and quality are selectable per camera.
All models have extensive alarm handling functions and telemetry control. Alarm functions include motion detection in user-definable areas of the image on any camera input.
The unit can be easily operated and programmed via the front panel control keys and on-screen display menu system. One monitor output provides full-screen, quad and multiscreen viewing; another spot/alarm. A keyboard can be connected to improve the ease-of-use.
Via a network, the Control Center PC-application can be used for live viewing, playback and configuration. The Divar includes an authenticity check for both local and remote playback. A dedicated PC player is provided for playback of secure video files.
Vers ions
There are three Divar models; 6-channel, 9-channel and 16-channel, each with various storage capacities. This manual describes the 16-channel version. Both 6­channel and 9-channel versions operate in exactly the same way except that fewer cameras can be connected, there are fewer camera keys and the number of multiscreen views is reduced.
Setup
The unit is configured by an administrator. Access to the configuration functions is normally password protected. The choices made during setup can restrict the functions available to the operator. For example, the number of multiscreen views can be limited.
Search and playback functions can also be password protected, so it is possible that they are not available to the operator. All possible operator facilities are described in this manual but some of these may not be available to you.
On-screen help
On-screen help is available for all topics. Just press the yellow ALT key for at least one second to see the help text associated with your current activity. Press
the escape key to exit help.
Philips Communication, Security & Imaging 3
English
Front panel controls
Front panel controls
Indicators
The power indicator lights to indicate that power is being supplied to the unit.
The indicators across the top of the unit light or flash to alert you to various operating conditions.
Record - lights when the unit is recording video.
Network - lights when a remote user is connected to the unit.
Alarm - flashes when an alarm is detected.
Motion - flashes when motion is detected in a camera signal.
Video loss - flashes when a video loss condition is detected for a
camera input.
Keys
The keys on the front panel can be used for controlling primary functions or alternate functions. Symbols for the primary functions are shown above the keys. Symbols for the alternate functions are shown below the keys.
The alternate functions are activated by first pressing the ALT key and then the desired key. When the alternate function mode is active, the light below the ALT key is lit.
The unit automatically exits the alternate mode if the monitor A key , monitor B key or sequence key is pressed. When in a menu, the keys
operate according to their alternate function.
4 Philips Communication, Security & Imaging
Primary functions
(light below ALT key off)
Front panel controls
English
Live key - press to switch to live viewing.
Search key - press to open a search menu to look for recorded
events.
Rewind key - in live mode, press to start reverse playback of
recordings for the displayed cameras.
- in playback mode, press to speed up rewind.
- in pause mode, press to step back one frame.
Pause key - in live mode, press to freeze a camera picture.
- in the playback mode, press to freeze playback picture; press for longer than one second to protect recordings.
Play key - in live mode, press to resume playback from the last
selected playback position.
- in pause mode, press to resume playback.
Fast forward - in live mode, press to start playback from one
minute earlier.
- in playback mode, press to speed up the playback rate.
- in pause mode, press to step forward one frame.
ACK key - press to acknowledge an alarm.
Multiscreen key- press to see different monitor display layouts.
ALT key - switches the front panel keys between a normal
function and an alternate function (shown below the key).
- press for longer than one second to get on-screen help.
1 - 16* Camera keys - press to see a full-screen display of the camera’s
picture.
- in the menu mode, press to select the camera or enter a number.
* can be 6, 9 or16 depending on model
Philips Communication, Security & Imaging 5
English
Front panel controls
Alternate functions
(light below ALT key is lit)
F1 key - restores defaults in active menu.
F2 key - is assigned a specific function in the menu.
Arrow keys: - move around through menu items or values.
-Left
-Up
-Down
-Right
Select key - selects a submenu or menu item, or saves selections
made in menus.
ESC key - press to return to previous level or to exit menu
system without saving.
- press to leave help system.
Menu key - opens the menu system.
Mon A key - assigns front panel keys to monitor A.
Mon B key - assigns front panel keys to monitor B.
Sequence key - view cameras in sequence on full-screen or quad
displays.
Zoom key - zooms in on the active camera display (full-screen or
active cameo).
6 Philips Communication, Security & Imaging
Loading...
+ 12 hidden pages