Packaging list
Exploded views
Pre-installation instructions
Installation steps
3. Get to know your
08
EasyKey
Outside escutcheon
Inside escutcheon
4. How to set up your
09
Easykey
Pre-setup instructions
Enter master mode
Modify master PIN code
Add a user record
Delete a user
System settings
Extended functions
System query
6. Other functions18
Safe handle function
Outside forced lock
One key to mute mode
Restore to default settings
7. Indicators meaning
20
and usage
Door lock status indicator
Low battery voltage indicator
Outside forced lock indicator
Mute indicator
Inside deadlock indicator
System freezing indicator
[OPEN/CLOSE] indicator
Indoor infrared sensor unlock
8. Troubleshooting22
Alert types and methods
How to charge EasyKey in an
emergency
How to replace batteries
5. How to use EasyKey15
Unlock from outside or inside
Lock from outside or inside
Inside deadlock
Unlock with mechanical key
1
1. Important information
2. EasyKey installation
Safety
Before using Philips EasyKey, please read
◆
and understand all instructions. Damage
caused by non-compliance with the
instructions will not be covered by warranty.
Use only the manufacturer-specied
◆
accessories/components.
Use only the alkaline batteries the
◆
product is equipped with, or use the same
specication type of alkaline batteries.
Do not forcibly disassemble this product
◆
to avoid triggering an alarm or damaging the
product.
Do not scrape the ngerprint sensor
◆
with sharp objects, otherwise it may cause
permanent damage.
Do not expose products to environments
◆
where there is water leakage or splashing.
Do not expose the product to corrosive
◆
substances to prevent damaging the
protective cover.
Do not hang objects on the handle, in
◆
case it might aect the normal use of the
lock.
Please clean the product with a soft cloth.
◆
Do not remove the battery during
◆
setting up and operating.
Please let a professional technician
◆
to install the door lock and follow the
installation guidelines provided. Do not
disassemble the lock by yourself. Keep the
relevant sealed stickers properly.
Please modify the default master PIN
◆
code immediately after nishing installing
and debugging, and do not easily disclose
the password information and also keep the
mechanical key properly.
Please replace all the batteries
◆
immediately if there is a low battery alarm.
Please make sure to correctly match the
poles (+/-) when installing the batteries.
Caution
Do not place the battery near re sources
◆
to avoid the explosion.
Do not use any emergency power supply
◆
that does not meet the safety requirements
to power up the product.
Do not connect the 2 poles of the
◆
batteries with metals to avoid short circuit
which may lead to an explosion.
Please make sure any component
◆
replacement is executed by Philips, Philips
authorized service center or professional
technicians.
Do not use accessories or parts that have
◆
been produced by other manufacturers or
have not been specically recommended
by Philips. The use of such accessories and
parts may void your warranty.
Disposal of used
products and batteries
You can have your locks reclaimed at
◆
Philips authorized service centers. You will
receive corresponding compensation if your
products meet our conditions.
Please familiarize yourself with the local
◆
electronic product collection system.
Please follow local regulations and do
◆
not discard used products into ordinary
household waste.
Proper disposal of used products can
◆
help to avoid potential negative impacts on
the environment and human health.
Batteries must not be disposed of with
◆
ordinary household waste.
Please familiarize yourself with the
◆
local regulations on batteries classication
recycling. Disposing of batteries properly
can help avoid a negative impact on the
environment and human health.
Packaging list
The pictures are for reference only, please refer to the actual packaging
items.
Drilling
Outside
①
escutcheon with
silicone pad
Mounting plate
⑤
Key tag
⑨
Installation kit
⑬
Inside
②
escutcheon with
silicone pad
Easy
Key
User
Manual
User manual
⑥
Mechanical key
⑩
Cleaning pad
⑭
③
template
Easy
Key
Warranty
Card
Warranty card
⑦
Batteries
⑪
Mortise
④
EasyKey
Certicate of
⑧
conformity
Strike
⑫
32
Exploded views
4
5
9
2
1
Pre-setup instructions
Step 1 | Determine door swing direction
3
This product allows you to have your door installed to go in four directions:
left outward, right outward, left inward and right inward.
Left-handed doorRight-handed door
6
7
1.
Deco cover *1
2.
M6 connecting screw*1
3.
M6 connecting screw tube*1
4.
Outside escutcheon*1
5.
Battery cover*1
6.
M6 mounting screw*1
7.
Inside escutcheon*1
Left inward
Left outward
Attention
1. Plea se choose the proper installat ion kit to suit your door thickness.
2. The default installation k it is applicable for a door thickness of 60-90mm. If your
door thickness does not w ithin this range, please feel free to contact us.
Right inward
Right outward
Step 2 | Change the orientation of the latch bolt
Loosen the screws by turning them
1
counterclockw ise with an Allen
wrench and remove the mortise
plate.
Mortise plate
Allen wrench
8
10111213
8.
Compressed spring *2
9.
Square shaft*2
10.
M5 connecting screw*4
11.
Mounting plate*1
12.
Mortise*1
M5 connecting screw tube*4
13.
Mount the mort ise plate and
3
fasten it with screws.
Mortise plate
Allen wrench
Take out the latch bolt and rotate
2
it to 180°, then put it back.
Latch
bolt
54
Installation steps
The following installation steps only apply to right-handed doors. For
left-handed doors, please read [Pre-installation instructions] carefully
and make necessary adjustments.
Mark the hole for drilling with
12
drilling template and drill the hole
marked, then mount the mortise
into the hole and fa sten it w ith
four anchor screws.
Attention
Make sure the latch bolt stays inside
the door during installation.
Install the connect ing screw tubes
on the outside escutcheon, and
put the compressed spring and
square shaft accordingly into the
square shaft holes.
M6 connecti ng
screw tube
Reserved cable
Attention
Escutcheon
cable
M5 connecti ng
screw tube
Please choose the proper square shaft
and connecting screw tube to suit your
door thickness.
Put the compressed spring and
56
square shaft into the square shaf t
hole of the inside escutcheon
accordingly.
Mortise cable
Reserved cable
Make sure the escutcheon cable and
the mor tise cable are hidden in the slot
on both sides of the square shaft, and
also hide the ex tra cables in the door
hole or the inside escutcheon.
Inser t the cable of both outside
escutcheon and mortise into the
corresponding sockets on the
inside escutcheon. Then insert
the square shaf t of the ins ide
escutcheon to the rotar y hole
on the mortise until the inside
escutcheon is close to the surface
of the door.
Mort ise ca ble
connector
Escutcheon
cable
connector
Attention
Pass the cable through the hole
3
and then insert the square shaf t
of the outside escutcheon to the
rotary hole on the mortise unt il
the out side escutcheon is close to
the sur face of the door.
Place the mount ing plate against
4
the inner surface of the door and
fasten it with four connecting
screws.
Mort ise ca ble
Escutcheon cable
Reserved cable
Remove the deco cover
78
and press the button
at the top of the inside
escutcheon to remove
the battery cover,
Put the deco cover
back, install the
batteries and install
the bat tery cover and
strike.
Check whether
9
the rotary knob,
mechanical key, and
all other components
work properly.
and fa sten the inside
escutcheon with two
M6 mounting screws.
Attention
After nishing the str ike installation, please check whether the smart
lock can lock or unlock normally.
76
3. Get to know your EasyKey
The pictures are for reference only, please refer to the actual packaging
items.
Outside escutcheon
Door lock status
①
indicator
Infrared sensor
②
Keypad
1
2
3
4
5
6
8
7
9
Inside escutcheon
4
3
5
6
2
10
11
8
7
1
③
Mute button
④
Outside forced lock
⑤
button
Handle
⑥
Low battery voltage
⑦
indicator
Card reader
⑧
Reset button
⑨
Keyhole
⑩
Emergency power supply
⑪
interface
Battery cover
①
Battery compartment
②
Auto/Manual mode
③
toggle switch
Reboot button
④
Communication and
network module
⑤
interface
OPEN/CLOSE】button
【
⑥
Rotary knob
⑦
Handle
⑧
4. How to set up your EasyKey
Pre-setup instructions
◆Philips EasyKey comes with two modes: General mode and Dual verication mode.
General modeUnlock w ith any registered identity information
Dual verication mode
◆User code
If you want to delete a specic user's informat ion, you could delete the related user
code in the system.
You can use the below template to write down all user information for review.
User
code
00
01
02
03
04
05
06
07
08
09
◆Icon annotation
Master
PIN
time PIN
code
1.Press [*] key to return to the previous menu.
2.The default master PIN code is 12345678.
code
Attention
Unlock w ith any t wo dierent verications among PIN
code, key t ag and ngerpr int.
NameFingerprintPasswordKeyta g
User
PIN
code
Fingerprint Key tag[#]One-
User
code
00-09
User
code
00-99
[*]
98
How to enter master
mode
Add a user recordDelete a user record
Add a user PIN code
Add a ngerprint
Delete a single user PIN code
Enter [#] and enter master PIN code,
then conrm with [#].
Light up the keypad and enter [#]
before you enter any other numbers,
then enter master PIN code a nd conrm
wit h [#].
Modify master PIN code
Enter [#] and enter master PIN code,
then conrm with [#].
1
Enter [1] to modify master PIN code.
Enter the new master PIN code and
conrm w ith [#]. Re-enter the same
master PIN code and conrm w ith
[#]. After hearing a voice prompt of
“Succeeded", press [*] to return to
previous menu until you nally ex it
master mode.
Enter [#] and enter master PIN code,
then conrm with [#].
2
Enter [2] to enter user registration and
enter [1] to add a new user PIN code,
then the system will automatically
number it and generate a voice prompt.
Enter a user PIN code of 6 to 12 digits
and conrm with [#]. Then re- enter the
user PIN code and conrm with [#].
After hearing a voice prompt of
“Succeeded", press [*] until you nally
exit master mode.
Add one-time PIN code
Enter [#] and enter master PIN code,
then conrm with [#].
1
22
Enter [2] to enter user settings, then
enter [2] again to add a one-t ime PIN code.
Enter a user PIN code of 6 to 12 digits
and conrm with [#]. Then re- enter the
user PIN code and conrm with [#].
After hearing a voice prompt of
“Succeeded", press [*] until you nally
exit master mode.
2
Enter [2] to enter user registration and
enter [3] to add a user ngerpr int, then
the system will automatically number it
and generate a voice prompt.
Place your nger on the ngerprint
sensor until you hear a voice prompt
of “Move your nger and put on
again". Lift your nger and repeat
the process until you hear a voice
prompt of “Succeeded". After you have
successfully registered your ngerprint,
press [*] until you nally ex it the
master mode.
Add a keytag
Enter [#] and enter master PIN code,
then conrm with [#].
2
Enter [2] to enter user registration and
enter [4] to add a user key tag, then the
system will automat ically number it
and generate a voice prompt.
Place the key tag against the card
reader. After hearing a voice prompt of
“Succeeded', press [*] until you nally
exit the master mode.
3
4
Enter [#] and enter master PIN code,
then conrm with [#].
Enter [3] to enter user record deletion
and enter [1] to enter user PIN code
delet ion, then enter [1] to delete a
single user PIN code.
Enter a 2-digit code (code: 00- 09) to
be deleted and conrm with[#]. After
hear ing a voice prompt of “Succeeded",
press [*] until you nally ex it the master
mode.
Delete all user PIN code
Enter [#] and enter master PIN code,
then conrm with [#].
Enter [3] to enter user record deletion
and enter [1] to enter user PIN code
delet ion, then enter [2] to delete all
user PIN code. After hear ing a voice
prompt of "Succeeded", press [*] until
you nally exit the master mode.
1110
Delete one-time PIN code
Delete all ngerprint
System initialization
Volume settings
Enter [#] and enter master PIN code,
then conrm with [#].
Enter [3] to enter user record deletion
and enter [2] to delete one-t ime PIN
code.
After hearing a voice prompt of
"Succeeded", press [*] until you nally
exit the master mode.
Delete a single ngerprint
Enter [#] and enter master PIN code,
then conrm with [#].
Enter [3] to enter user record deletion
and enter [3] to enter user ngerprint
delet ion, then enter [1] to delete a
single ngerprint.
Enter a 2-digit code (code: 00-99) to
be deleted and conrm with[#]. After
hear ing a voice prompt of “Succeeded',
press [*] until you nally ex it the master
mode.
Enter [#] and enter master PIN code,
then conrm with [#].
Enter [3] to enter user record deletion
and enter [3] to enter user ngerprint
delet ion, then enter [2] to delete
all ngerprint. After hear ing a voice
prompt of “Succeeded", press [*] until
you nally exit the master mode.
Delete a keytag
Enter[#] and enter ma ster PIN code,
then conrm with [#].
Enter [3] to enter user record deletion
and enter [4] to enter keytag record
delet ion, then enter [1] to delete a
single keytag record. After hearing a
voice prompt of "Succeeded", press [*]
until you nally exit the master mode.
Delete all keytag
Enter [#] and enter master PIN code,
then conrm with [#].
Enter [3] to enter user record deletion
and enter [4] to enter user keytag
delet ion, then enter [2] to delete all
keytag. After hear ing a voice prompt of
“Succeeded", press [*] until you nally
exit the master mode.
Remove the battery cover, then double
press the [RES] hole with a sharp
object. When you hear a voice prompt
of “Restoring to default settings", it
means all user record is emptied.
System settings
Language settings
Enter [#] and enter master PIN code,
then conrm with [#].
Enter [4] to get into system sett ings
and enter [1] to get into language
settings.
or
Choose the language as needed: For
Chinese, press [1]; for English, press
[2]. After hearing a voice prompt of
“Succeeded", press [*] until you nally
exit the master mode.
Attention
The default language is English.
Enter [#] and enter master PIN code
and conrm with [#].
Enter [4] to get into system sett ings
and then enter [2] to enter into volume
settings.
oror
Choose the volume as needed: For
high volume, press [1]; for low volume,
press [ 2]; for mute mode, press [3].
After hearing a voice prompt of
“Succeeded", press [*] until you nally
exit the master mode.
Attention
The default volume is "high volume".
Switch to dual verication mode
Enter [#] and enter master PIN code,
then conrm with [#].
Enter [4] to go into system sett ings, then
enter [3] to go into dual verication
mode.
or
For single verication mode, please
press [1]; For dual verication mode,
press [ 2]; After hearing a voice prompt
of “Succeeded", press [*] until nally
you exit master mode.
1312
Extended functions
Local query
5. How to use EasyKey
Enter [#] and enter master PIN code,
then conrm with [#].
Enter [5] to go into extended functions.
or
Enter [1] to join a net work. Enter [2] to
exit a network. Before entering into
the extended f unct ion settings, please
download and open the TmallGenie
APP on your mobile phone.
Attention
The extended funct ions are optional.
System query
Secur ity code query
Enter [#] and enter master PIN code,
then conrm with [#].
Enter [6] to go into system quer y, and
enter [2] to check the software version,
then the system will broadcast it
automatically.
Attention
Directly enter 114# to go into the local
que ry.
Unlock from inside or outside
Unlock from outside
With PIN codeWith ngerprintWith key t ag
1
Keypad
①Touch the digit input area
to light up the keypad and
enter the registered PIN
code and conrm with [#].
②After hear ing a voice
prompt of “Door opened",
push or pull the door to
unlock.
Unlock from inside
With a rotary knobWith a functional
2
Push or
pull to
unlock
1
Fingerprint
sensor
①Place the registered
nger on the ngerprint
sensor.
②When you hear a voice
prompt of "Door opened",
push or pull the handle to
unlock.
button
22
Push or
pull to
unlock
1
Card
reader
①Place the registered card
against the card reader.
②When you hear a voice
prompt of "Door opened",
push or pull the handle to
unlock.
With an infrared
sensor
Push or
pull to
unlock
Enter [#] and enter master PIN code,
then conrm with [#].
Enter [6] to go into system quer y, then
enter [1] to check the secur ity code
and the system w ill automatically
broadcast the produc t series number.
Attention
Directly enter 400# to go into system
que ry.
Philips EasyKey adopts
indoor fast opening
mort ise. You can unlock
the door from inside by
rotat ing the rotary knob.
Double press the [OPEN]
functional button within
one second, then push or
pull to unlock the door.
Philips Easykey has an
infrared sensor on the
handle. When the sensor is
triggered, you can press the
sensor module on both the
front and rear sides of the
handle simultaneously to
unlock the door.
1514
Lock from outside or insideInside deadlock
Aut o/Ma nua l
mode toggle
switch
Lock from outside
[A] indicates auto
mode. When the
door is close, the
latch bolt will pop up
automatically and
the lock is locked.
[M] indicates
manual mode.
When the door is
close, the latch bolt
will not pop up and
the lock is normally
opened.
Upon entering the auto mode, the latch bolt w ill pop up
automatically as soon as the door is close and there will be a
voice prompt of “Door Close”.
Upon entering the manual mode, the latch bolt will not pop up
when the door is close. The verication methods as ngerprint,
PIN code, or key tag are required to have the latch bolt
popped up. There will be a voice prompt of “Door Close” after
the door is successfully locked. You can light up the outside
escutcheon to release the mode and unlock the door.
When the EasyKey is locked, long press the
[CLOSE] button until the indicator ashes
once in red, then there will be a voice
prompt of “Inside deadlock enabled".
Attention
When the door is under inside deadlock
mode, the outside escutcheon w ill lock up. If
you try to wake up the system manually, the
keypad area will display the combination of
“15937(X)” and there w ill be a voice prompt of
“Inside deadlock enabled" to remind you that
the door has been deadlocked from inside.
Under deadlock mode, all operat ions of the
outside escutcheon are disabled. Master PIN
code ver ication or mechanical key opening
is required to release the door from deadlock
mode.
Unlock with mechanical key
Lock from inside
Upon entering the auto mode, the latch bolt w ill pop up as
soon as the door is close and there will be a voice prompt of
"Door closed".
Upon entering the manual mode, the latch bolt will not pop
up when the door is locked. Double click the [CLOSE] button
to have the l atch bolt popped up. After locking successf ully, a
voice prompt of "Door closed" will be triggered.
Push button
① Cut the mechanical
box and take out the
key. Push the cover
aside and reveal the key.
② Inser t the key into
the keyhole and the key
should be vert ical to the
key shell. Then turn the
key shell by 90° in the
direc tion of the handle
until it is close to the
lock.
③ Make a 180 degrees
twist clock wise a nd
make sure the key
shell is parallel to the
horizontal plane. Then
rotate the key cover
horizontally in the
direc tion of the handle
to unlock.
1716
6. Other functions
Indoor infrared sensor unlockingMute mode
Infrared sensor
Rear inductive position
Front inductive position
Attention
When the infrared sensor unlocking
is disabled, the indoor inductive
unlock ing would be inactive. When
you touch both the front and rear
side of the inductive position on
the handle, the red light will light
up to remind you that the indoor
inductive unlocking is o.
Outside forced lock
Outside forced lock button
Function:
With indoor infrared sensor unlocking,
you could easily unlock the door from
inside.
How to use:
Philips Easykey has an infrared sensor
on the handle. When the sensor is
triggered, you can press the sensor
module on both sides of the handle
simultaneously to unlock the door.
Enable/Disable:
When the infrared sensor unlocking is
disabled, long press the [OPEN/CLOSE]
button at the same time to turn on the
function, and the green light will glow
quickly;
When the infrared sensor unlocking is
enabled, long press the [OPEN/ CLOSE]
button at the same time to turn o the
function and the red light will glow
quickly.
Function:
Unlocking from inside will trigger an
alert.
How to use:
After the door is successfully locked,
long press the button for 2 seconds to
enter the outside forced lock mode.
Attention
Enabling the out side forced lock function
will not aect the normal way to unlock the
door from outside.
Mute button
Restore to default settings
Function:
Use only one button to mute the
lock and the voice guide will be
turned o. This feature applies to
the scenes where you don't want to
disturb your family.
How to use:
1. Mute: When the system is awake,
long press the [Mute] button for 2
seconds until it glows green.
2. Unmute: When the system is
awake, long press the [Mute] button
for 2 seconds until it glows white
and the lock will produce sound
again.
Function:
Empty all user information and
restore the EasyKey to default
settings.
How to use:
Use a sharp object to double press
the [RES] button, and all the user
information will be empt ied, then
the lock will be restored to default
settings.
1918
7. Indicators meaning and usage
Mute mode indicator
Door lock status indicator
Blue: When the system wakes up
and the light glows blue, it means
you can use the lock.
Door lock
status indicator
Green: When the door is unlocked
and the light glows green, it means
the door is open.
Red: When the door is locked and
the light glows red, it means the
door is closed.
Low battery voltage indicator
Red: When the system wakes up,
it will automatically check the
battery voltage. If the voltage is
too low, then the light will ash
in red and there will be a voice
Low battery
voltage indicator
prompt of “Low battery voltage,
please replace all batteries".
Outside forced lock indicator
White:
1. When the door is locked and the
light glows in white, it means that
you can enable the outside forced
locking function.
2. Upon the outside forced
Outside forced
lock indicator
function is enabled, the light
will glow in white as soon as the
system wakes up.
1.White: indicates the mute mode
is o.
2.Green: indicates the mute mode
is on.
Mute mode
indicator
Inside deadlock indicator
When the door is under inside
deadlock mode, the keypad will
lock. If you wake up the system
manually, the keypad will show the
combinat ion of “15937 (X)” with a
voice prompt of "inside deadlock
enabled ".
System freezing indicator
Flash three timesFlash twiceFlash once
3 minutes
2 minutes1 minute
If there are consecutive
incorrect inputs of any
of the ngerprint, PIN
code, or key tag 5 times
within 5 minutes, the
system will lock up for 3
minutes.
Attention
Only when waking up
the outside escutcheon
or verifying the identit y
of the user would the
numbers appear.
2120
[OPEN/CLOSE] indicator
1. Red light ashing twice: indicates that
the door is locked successfully.
2. Green light ashing tw ice: indicates that
the door is unlocked successfully.
3. Red light ashing once: indicates that
the door is under the deadlock mode.
Infrared sensor unlocking indicator
1.Fast ashing in green: infrared sensor
unlocking is on.
2.Fast ashing in red: infrared sensor
unlocking is o.
8. Troubleshooting
Alert types and methods
Low battery alert reminds you to replace the batteries
Way to trigger: When the system wakes
up, it will automat ically check the battery
voltage. If the voltage is too low, then an
alert will be triggered to remind you to
replace the batteries.
Way to be alerted: A voice prompt of
“Low battery voltage, please replace all
batteries" w ill be given when unlocking the
door.
Way to turn o: The alert will be
automatically turned o.
Anti-dismantling alert
1. Way to trigger: The door is pried apart
and the latch bolt is popped up.
Way to be alerted: Repeat alerts.
Way to turn o: Automatically turning o or
successful identity verication.
2. Way to trigger: The outside escutcheon
is pried open and there is a gap of space
between the door and the outside
escutcheon.
Way to be alerted: Repeat alerts.
Way to turn o: Automatically turning o or
successful identity ver icat ion or a normal
way to unlock the door from inside.
Alert to unlock from inside under outside forced lock mode
Way to trigger: Upon enabling the outside
deadlock mode, an alert will be triggered
when you unlock the door from inside.
Way to be alerted: Repeat alerts
Way to turn o: The alert will be turned o
once the identity verication is successful.
Anomalous deadbolt alert
Way to trigger: The deadbolt works
abnormally or a failure in lock ing or
unlocking the door.
Way to be alerted: Repeat alerts
Way to turn o: The alert will be
automatically turned o.
2322
How to charge EasyKey in an emergency
When th e batte ry volt age is low, a nd the
door cannot be opened from
outs ide, you can power up the lock by
plugg ing 5V power bank into the micro
Reboot
button
Emergency power
supply interface
USB. Af ter the door is unlocked, please
replace the bat teries inst antly.
If the sy stem cra sh occurs and the door
can not b e unlocked from out side, please
press a nd relea se the re boot but ton to
restart the system.
How to replace batteries
To keep the batteries running longe r and
save you from repl acing t he batteries
repeatedly, the lo ck is power ed by 1.5V
alkaline bat teri es and ca n contain eight
batteries at the same time.
Battery
cover button
Battery
cover buckle
The battery compar tment is in the lower
part of the inside escutcheon. Press the
button near the botto m of the ins ide
escutcheon, then remove the battery
cover. By pushing the batter y cover
buckle upwards , you can pull the batter y
compartment out and replace the batteries.
24
Philips and the Philips Shield Emblem are registered trademarks of Koninklijke
Philips N.V. and are used under license. This product has been manufactured by and
is sold under the responsibility of Shenzhen Conex Intelligent Technology Co., Ltd.
and Shenzhen Conex Intelligent Technology Co., Ltd. is the warrantor concerning this
product.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.