Onwards 0023 the Ivory version with a new motor will be introduced.
The available spares are for this version:
1 4822 528 20732 Drive coupling 2 4822 441 12284 Housing assy 3 4822 410 12161 Switch knob 4 4822 492 70949 Switch spring 5 4206 133 92200 Upper insert set
6 4206 136 49530 Motor 230 V twister 7 4206 133 53190 Buffer 8 4822 441 12285 Bottom plate 9 4822 462 40374 Foot 10 4206 133 92190 Lower insert set
11 4822 273 10227 Switch 13 4822 401 10204 Bracket 14 4822 321 10364 Cord (standard) A 4822 502 30054 Screw 4822 130 31124 Diode on switch
16 4822 462 11134 Jar cap 17 A 4822 442 01615 Jar lid G 4822 442 01616 Jar lid 18 4822 690 10188 Spatula 19 A 4822 418 40882 Synth. jar (max. 1.5 l) G 4822 418 10395 Glass jar
21 A 4822 532 52356 Sealing ring G 4822 532 51841 Sealing ring 22 A 4822 690 40246 Knife unit G 4822 690 10187 Knife unit 23 4822 528 20731 Driven coupling
24 A 4822 532 13094 Interface G 4822 532 13095 Interface 30 4822 418 10401 Cup 31 4822 532 51841 Sealing ring 32 4822 690 40248 Knife unit
33 4822 528 20731 Driven coupling 34 4822 532 13095 Interface
Blender HR 2815/B
DAP248
Service
A = tobe used with synthetic jar G = tobe used with glass jar
16
1
17
18
2
19
3
10
4
5
7
11
5
21
6
13
A
14
23
22
10
24
8
9
brown
MAINS
blue
A
M
0
1
2
Speed switch blade Motor assy
DIODE
grey
grey 2
13
30
31
32
33
34
DAP1273